Search:

Type: Posts; User: KlRadiant

Search: Search took 0.01 seconds.

  1. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    shark bites have saved my ass way too many times...

    shark bites have saved my ass way too many times .. here's a couple of examples;

    once i had to remove a system from an industrial unit .. the idiot that built the system had hooked up the make up...
  2. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    that's why god invented sharkbites

    that's why god invented sharkbites
  3. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    i hear ya .. it saves a lot of time in that event...

    i hear ya .. it saves a lot of time in that event trying to purge the air back out of the system

    my strategy is i try to isolate sections, and i have been using the expandable taco boxes with the...
  4. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    the flanges with ball valves built in ??? yea,...

    the flanges with ball valves built in ??? yea, one of the jobs i did last month my supplier shipped them to me by accident, and i accidentally forgot to say any thing about it

    they were grundfos...
  5. Thread: banbury job

    by KlRadiant
    Replies
    5
    Views
    1,403

    thanks fellas

    thanks fellas
  6. Thread: banbury job

    by KlRadiant
    Replies
    5
    Views
    1,403

    banbury job

    https://fbcdn-sphotos-a.akamaihd.net/hphotos-ak-ash4/s720x720/295460_10151097124575792_1274455533_n.jpg
  7. Replies
    10
    Views
    2,125

    venting isn't mine joe .. code up here in frosty...

    venting isn't mine joe .. code up here in frosty canadia allows mixing products on the intake side as far as i know, but i agree it looks like ass
  8. Replies
    10
    Views
    2,125

    lwco's make no sense to me either .. these nti's...

    lwco's make no sense to me either .. these nti's have overheat protection that shuts them down way before the lwco ever trips .. but it's code ..... so

    the building inspector at one job i did made...
  9. Replies
    10
    Views
    2,125

    ***bingo*** .. i have no excuse

    ***bingo*** .. i have no excuse
  10. Replies
    10
    Views
    2,125

    another quickie

    spartan nti trinity build running an air handler and an indirect .. spot the glaring error and win a lollipop
    ...
  11. Replies
    10
    Views
    1,685

    boilers are like dogs, give them a job to do that...

    boilers are like dogs, give them a job to do that occupies them correctly and they're happy .. if you don't they usually end up peeing all over your floor
  12. Thread: Boiler job

    by KlRadiant
    Replies
    13
    Views
    2,448

    when you do demonstrate clean workmanship you...

    when you do demonstrate clean workmanship you deserve to be called 'sir' by your peers, no matter what your age is
  13. Thread: Boiler job

    by KlRadiant
    Replies
    13
    Views
    2,448

    x2 for the caleffi air eliminator nice clean...

    x2 for the caleffi air eliminator

    nice clean plumb pipe sir :cheers:
  14. Replies
    10
    Views
    1,685

    as a rule i always try and mount the expansion...

    as a rule i always try and mount the expansion tank in the vertical plane, maybe i'm old school as the kids say

    otherwise stellar work, i bet that boiler is way happier with the extra volume
  15. Replies
    5
    Views
    1,651

    trying to study that last pic norm caused me to...

    trying to study that last pic norm caused me to almost fall off my computer desk

    are a watts man, uponor or completely nonpartisan ???
  16. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    thanks fellas, here's another, rinnai combi in...

    thanks fellas, here's another, rinnai combi in bolton ontario, reno job .. again i didn't do the tube in the floor & the plumber hasn't hooked in on either side yet .. there's another manifold worth...
  17. Thread: first post

    by KlRadiant
    Replies
    15
    Views
    2,567

    first post

    rinnai doing double duty, dhw and 1200 sq of basement in floor in a cottage on balsam lake ontario

    https://fbcdn-sphotos-a.akamaihd.net/hphotos-ak-ash3/536766_280706418686782_2068895074_n.jpg

    i...
Results 1 to 17 of 17
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event