Search:

Type: Posts; User: Coolingfolks

Search: Search took 0.00 seconds.

  1. Replies
    58
    Views
    8,063

    Fluke for me all the way.

    Fluke for me all the way.
  2. Replies
    204
    Views
    30,935

    Great subject! I have a couple dozen...

    Great subject!

    I have a couple dozen flashlights around that I have experimented with, my problem is finding the batteries have died. So my solution is my iPhone, it has a great light and I always...
  3. Replies
    5
    Views
    1,554

    I haven't heard of that company but I'm sure they...

    I haven't heard of that company but I'm sure they have more than one person doing hook ups. They need to have a QC person follow up their installers. I've seen garbage like that here in my area that...
  4. Replies
    3
    Views
    699

    Dandyme Thanks for the welcome. I should have...

    Dandyme
    Thanks for the welcome. I should have used a different phrase and not dropping in from time to time. Hopefully I will be able to login frequently and get my post count up pretty quickly.
  5. Replies
    29
    Views
    3,095

    When you say the compressor starts for a second...

    When you say the compressor starts for a second then shuts down, I am assuming the contactor is not opening and the compressor is going out on thermal. This combined with the info that you are...
  6. A blower door test would give you an idea of how...

    A blower door test would give you an idea of how much air leakage you are getting. Around here in North Georgia, I have only seen one system with underground duct and it was PVC.
  7. Replies
    27
    Views
    3,176

    The problem with some blended refrigerants is...

    The problem with some blended refrigerants is they have a different glide....meaning in the event of a leak, all the other ingredients may leak out leaving you with pure liquid propane. This stuff...
  8. Replies
    3
    Views
    892

    I would probably give you a shot if everything...

    I would probably give you a shot if everything else checked out as long as it was a long time ago and not a felony. I would also keep you on a short leash until you earned my trust. Do yourself a...
  9. Replies
    24
    Views
    3,467

    I can't speak for others but Carrier literature...

    I can't speak for others but Carrier literature includes a balance point work sheet in the product data guide. I can't imagine a spread sheet saving time compared to already having specific capacity...
  10. Thread: sequencer

    by Coolingfolks
    Replies
    28
    Views
    3,731

    I don't like sequencers, but the manufacturers...

    I don't like sequencers, but the manufacturers use them for price I guess. I almost always replace with contactors.
  11. Replies
    42
    Views
    5,201

    Just a thought...I have seen faulty roll out...

    Just a thought...I have seen faulty roll out switches. I had a 90plus furnace kick my butt for a week, changed the switch and never had another issue with it. Luckily it was a friends system.
  12. Replies
    3
    Views
    699

    Hello from North Georgia

    Just a note to say hello, I am new here but I've been in the business a few years. Will be checking in from time to time. Hope to make some new friends
  13. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
Results 1 to 13 of 13
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event