  1. Replies
    15
    Views
    1,297

    Get a second opinion!!:gah:

    Get a second opinion!!:gah:
  2. Replies
    28
    Views
    1,894

    Been a lifetime member of the NRA for over 20...

    Been a lifetime member of the NRA for over 20 yrs and proud of it !!!
  3. Replies
    5
    Views
    967

    Package units are avaliable in AZ now. New...

    Package units are avaliable in AZ now. New splits-- first of March I heard.
  4. I too atended one of Jim's classes. Well worth...

    I too atended one of Jim's classes. Well worth it!!!

    Just don't treat your meters like Jim treats his!!!! (LOL)
  5. edit

    edit
  6. Replies
    37
    Views
    3,907

    If you live where the temp. gets up there in the...

    If you live where the temp. gets up there in the hot months (AZ -- parts of Cal) your better of with r-22. 410-a has some real issues in heat. It's capacity to transfer btu's is not what it should...
  7. Replies
    12
    Views
    1,109

    If you are tying your flue (natural draft)into a...

    If you are tying your flue (natural draft)into a new furnace(induced draft) you should put baramertic dampers with spill switches in both flues to insure proper draft for both. Plus it's a saftey...
  8. Thread: paysonhvac

    by danj
    Replies
    15
    Views
    2,748

    Most of the airhandlers are in the attic's!!! In...

    Most of the airhandlers are in the attic's!!! In the heat of the day , package equipment looks good!!!
  9. Replies
    6
    Views
    817

    There isn't an adjustment on the fluke 16. Don't...

    There isn't an adjustment on the fluke 16. Don't worry-- have used mine for years with no problems. I have wore out a few pipe clamps, but the meter keeps on a ticking!!
  10. Replies
    47
    Views
    3,419

    CCC

    CCC
  11. Replies
    33
    Views
    2,617

    Now live in COOL Glendale Arizona. lol Yea--

    Now live in COOL Glendale Arizona. lol Yea--
  12. Thread: Capacitor voltage

    by danj
    Replies
    31
    Views
    2,952

    Jack You can take your amps of the start...

    Jack You can take your amps of the start winding x 2653 then divide that by the voltage your reading at your capicitor and that will tell you how many mfd you capacitor is putting out under a...
  13. Replies
    51
    Views
    3,522

    Your problem might just be 410 a. It's latent...

    Your problem might just be 410 a. It's latent capacity drops off fast at high temps.(much more than r-22) We are seeing a lot of units(puron) that are not able to hold 78 in the afternoons.They...
  14. Replies
    17
    Views
    2,465

    Yes ,there are different pitches on blades. The...

    Yes ,there are different pitches on blades. The wrong pitch can and will cause pre-mature motor failure (not enough air over the motor) Too much pitch-- over-amping of the motor. That's just what can...
  15. Replies
    35
    Views
    4,798

    Amps of the start winding---Voltage --back EMF--...

    Amps of the start winding---Voltage --back EMF-- between start and run.
  16. Thread: ghost fan..??

    by danj
    Replies
    18
    Views
    1,300

    You may need a resistor between G and C to stop...

    You may need a resistor between G and C to stop the ghost fan.
  17. Replies
    11
    Views
    1,406

    Some carriers have a internal liquid line filter...

    Some carriers have a internal liquid line filter dryer-- sounds like it may be plugged.

    Check the temp. across the dryer, should be less than 3 degrees.
    Sounds like you have a restriction...
  18. Replies
    31
    Views
    2,485

    In the Phoenix area,we sugest twice a year for...

    In the Phoenix area,we sugest twice a year for some-- once a year for others-- Like Yuma said , the equipment takes a pounding here in the summer. Once before cooling season and once before heating...
  19. Replies
    13
    Views
    1,706

    I think water boils at 212 degrees at 14.7 psi...

    I think water boils at 212 degrees at 14.7 psi (pressure at sea level)
  20. Replies
    50
    Views
    51,543

    95% of the homes in Phoenix were sized with...

    95% of the homes in Phoenix were sized with 400-450 sq.ft. per ton. The 400 ft. comes in if you have high vaulted ceilings. Most are sized with 450 sq.ft. per ton. You can look what size a unit is...
  21. Thread: return or supply?

    by danj
    Replies
    3
    Views
    797

    Why not put in 2 returns and a supply?

    Why not put in 2 returns and a supply?
  22. Replies
    5
    Views
    1,114

    When possible, cross check using at least 2...

    When possible, cross check using at least 2 methods. Start with a charging chart in the unit. It has its limitations though, if your air flow is less than 400 CFM per ton(most are ) and your line set...
  23. Replies
    41
    Views
    3,832

    It sounds like Dash and tinknocker are right...

    It sounds like Dash and tinknocker are right --air-flow. One way to check is to lock the unit in low fire turn your t-stat up like you normally do and see if you get a malfunction. If you don't get a...
  24. Thread: defrosting

    by danj
    Replies
    7
    Views
    917

    Well, I think most all package equipment(carrier...

    Well, I think most all package equipment(carrier 50JX 50JZ and 50XZ)--still use time and tempt. as do the carrier split pumps 38yra's 38bco's 38yxa's(puron). The heil--tempstar--...
  25. Thread: defrosting

    by danj
    Replies
    7
    Views
    917

    Time AND tempture acuated---- Time OR tempture...

    Time AND tempture acuated---- Time OR tempture terminated. You need the time( 30-60-90 min depending on the setting )and a outdoor coil temp. of 27 degrees to close defrost sensor to start the...
Results 1 to 25 of 247
Page 1 of 10 1 2 3 4