  1. Replies
    25
    Views
    1,400

    having a tech work for or maby a newby you work...

    having a tech work for or maby a newby you work with that is inexperianced is one thing having one thats inexprianced and you ask him to test certain crusial things when diognosing a problem and...
  2. Replies
    46
    Views
    16,860

    lets put propane in our auto a/c systems too lol

    lets put propane in our auto a/c systems too
    lol
  3. sealant additives/ are an approved method.....

    i work out of the province of ontario...and have to confirm leak free.....is this possible with leak freeze or others ....how quickly do they respond...thanks
  4. Replies
    5
    Views
    727

    sorry...... purge the gas

    sorry...... purge the gas
  5. Replies
    5
    Views
    727

    my advice would be to ourge all the (unkown gas )...

    my advice would be to ourge all the (unkown gas ) then fillit...safety first
  6. Replies
    10
    Views
    907

    i need a bender that will do 3/8 to 3/4...... ...

    i need a bender that will do 3/8 to 3/4...... ive never used a spring bender. would it work on 3/4 ebay has only small diamater ones .....a decent canadian wholesaler maby
  7. Replies
    10
    Views
    907

    looking for a 180 degre bender

    hello....im hoping to find a 180 degree tube bender

    im located in ontario and would appreciate any help locating one


    thanks
  8. Replies
    8
    Views
    768

    domestic hot water and boiler it will also...

    domestic hot water and boiler it will also provide for in floor heat and also heat a small pool
  9. Replies
    8
    Views
    768

    check out the mattrix it be just what you looking...

    check out the mattrix it be just what you looking for
  10. Replies
    24
    Views
    1,093

    thank you very much

    thank you very much
  11. Replies
    24
    Views
    1,093

    i'm not sure how to do that

    i'm not sure how to do that
  12. Replies
    24
    Views
    1,093

    the voltage ...220 or so i didnt put a meter on...

    the voltage ...220 or so i didnt put a meter on it
    residential single phase
  13. Replies
    24
    Views
    1,093

    calm down..i asked a question hoping to learn...

    calm down..i asked a question hoping to learn something. not get bashed ..ive been in the trade for twenty years mostly residential but ive worked on a lot of commercial units as well
    i may not be a...
  14. Replies
    24
    Views
    1,093

    dude were talking about the compressor not the...

    dude were talking about the compressor not the house voltage (try to keep up\
  15. Replies
    24
    Views
    1,093

    i figured i would have to adjust charge for...

    i figured i would have to adjust charge for length of lines but the sub cooling is ok
    thats whats confusing me
  16. Replies
    24
    Views
    1,093

    its a keeprite and sorry im not an electrician...

    its a keeprite and sorry im not an electrician ,im licensed in a/c
  17. Replies
    24
    Views
    1,093

    single phase

    single phase
  18. Replies
    24
    Views
    1,093

    its residential cant say for sure

    its residential
    cant say for sure
  19. Replies
    24
    Views
    1,093

    how would i check that

    how would i check that
  20. Replies
    0
    Views
    256

    noisy scroll

    i installed a retrofit 410 system,repl,aced coil condenser and liquid line..50 feet ..
    i checked sub cooling(txv) it was bang on running at 4.5 amps..wierd

    the only thing is that the compressor...
  21. Replies
    24
    Views
    1,093

    i didnt add any ref either

    i didnt add any ref either
  22. Replies
    24
    Views
    1,093

    noisy scroll

    i installed a retrofit 410 system,repl,aced coil condenser and liquid line..50 feet ..
    i checked sub cooling(txv) it was bang on running at 4.5 amps..wierd

    the only thing is that the...
  23. be very carefull when switching breakers to an...

    be very carefull when switching breakers to an appliance (especially one with a problem)
    stand to the side theres always the chance of a plasma blast
  24. Replies
    57
    Views
    5,250

    digi-cool btd 1000

    i searched for this item but they said on the web page that that this product was unavailable ??????:cool:
  25. Replies
    26
    Views
    2,124

    leak or no leak

    checking for a leak can be difficult depending where it is,of course.
    if it isn't in the condenser or service valves its not so bad.
    pump down, pressurise, and soap. toooo easy