Search:

Type: Posts; User: roadking44

Search: Search took 0.01 seconds.

  1. Jets going to spank that a**.

    Jets going to spank that a**.
  2. Replies
    4
    Views
    452

    I can view when im not logged in but when I log...

    I can view when im not logged in but when I log in it gives me this page.


    roadking44, you do not have permission to access this page. This could be due to one of several reasons:

    Your user...
  3. Replies
    4
    Views
    452

    I think so. Is this a private forum now? Still...

    I think so. Is this a private forum now? Still not letting me in.
  4. Replies
    4
    Views
    452

    Tricks of the trade

    Is there still a trickes of the trade forums?
  5. Replies
    137
    Views
    8,668

    Used to smoked 2-1/2 packs a day for 30yrs. but...

    Used to smoked 2-1/2 packs a day for 30yrs. but now i've been quiet for 1 1/2 yrs. Chewing the hell out of gum right know.
  6. Replies
    8
    Views
    910

    Shout chiller off and see if level comes up to...

    Shout chiller off and see if level comes up to +1.1. You can get a sight glass and hoses to check level in barrel. If you shout it down and senor does not move then either float stuck or sensor bad...
  7. Thread: Rittling

    by roadking44
    Replies
    2
    Views
    853

    I've never heard of Rittling. I would be scared I...

    I've never heard of Rittling. I would be scared I wouldn't be able to get parts years down the line. I Just started up about 150 trane fcu's and they work great. Never seen a McQuay fcu in a while...
  8. Replies
    13
    Views
    2,390

    I used to use a usb to 9 pin adaptor on mine....

    I used to use a usb to 9 pin adaptor on mine. Still have to have teck view to see anything.
  9. Replies
    1
    Views
    454

    You probably get more response if you post this...

    You probably get more response if you post this in the control area.
  10. Replies
    5
    Views
    632

    I just use a two old hoses and a sight glass in...

    I just use a two old hoses and a sight glass in between for checking level. I use clear hoses for charging centervacs.
  11. Replies
    7
    Views
    3,583

    I hadn't had any leak either.

    I hadn't had any leak either.
  12. Replies
    21
    Views
    1,747

    Could have a bad regulator.

    Could have a bad regulator.
  13. Replies
    27
    Views
    2,684

    We hadn't had that problem here (ms.) What is in...

    We hadn't had that problem here (ms.) What is in the kit? I work for Trane and seen a kit.
    You dont want to order nothing from the factory right now. They are about 1000 orders behind because of the...
  14. Replies
    5
    Views
    1,133

    We work on alot of Munter units and have not...

    We work on alot of Munter units and have not heard that. Still selling them down here.
  15. Replies
    7
    Views
    1,016

    They bought Trane several months ago.

    They bought Trane several months ago.
  16. Replies
    8
    Views
    703

    Put the vaccum gauge on your pump and make sure...

    Put the vaccum gauge on your pump and make sure its pulling down to a couple hundred microns. Make sure evap. and cond. water valve are closed tight. Make sure there's no flow through chiller. You...
  17. Replies
    117
    Views
    11,694

    The guy who got fired with us was spending more...

    The guy who got fired with us was spending more time at his tobacco store then at work. We have 46 trucks on the road so it stopped people using them after hours. Was long as your honest then you...
  18. Replies
    117
    Views
    11,694

    Yea, We've had if for about 2yrs now. It's...

    Yea, We've had if for about 2yrs now. It's already got one guy fired. They can tell where you are and how fast your going and if your truck is idealing for more then 30min. We've got use to them.
  19. Replies
    3
    Views
    644

    I've replaced one on a rthd before. Have to...

    I've replaced one on a rthd before. Have to reclaim freon and unscrew float from the bottom and replace. Go in tech veiw and rebind llid. Not bad but just takes a while to reclaim freon.
  20. Replies
    12
    Views
    1,143

    Sounds like a low end surge because of no load....

    Sounds like a low end surge because of no load. Trane bad abou that. Put a load on it and it will go away.
  21. Bet its low on refr. oil logged evap. Leak check...

    Bet its low on refr. oil logged evap. Leak check solenoid valve around gas pump that going from pump to condenser ( drain solenoid valve). I bet its leaking when its entergized. I leak checked one...
  22. Replies
    14
    Views
    1,564

    Slide valve is not bad. Just order a slide valve...

    Slide valve is not bad. Just order a slide valve kit. It will have a gasket and round disk ( slide valve). Valve out compressor and take discharge plate off and you will see slide valve. Swap out...
  23. Replies
    14
    Views
    1,564

    Stuck slide valve will cause that. We change lip...

    Stuck slide valve will cause that. We change lip seal all the time in field. Most likely it's just slide valve.
  24. Replies
    27
    Views
    3,407

    Looks good! Not sure about how long arm will last...

    Looks good! Not sure about how long arm will last but screen is real sharp. Does anybody know when they will be installed on new chillers and if they will come installed on door instead of arm?
  25. Replies
    14
    Views
    1,564

    Slide valve stuck loaded. That's why its starting...

    Slide valve stuck loaded. That's why its starting at 85%. Replace slide valve and we normally go on and do lip seal to if not already done. Cuts down on another call later.
  26. Replies
    23
    Views
    2,082

    Our Trane office don't have them yet. We do take...

    Our Trane office don't have them yet. We do take care of 2 plants where they are starting to make you wear them but luckly I have not had to yet.
  27. Thread: Heat trace

    by roadking44
    Replies
    1
    Views
    553

    I've seen it both ways. Wouldn't hurt being its...

    I've seen it both ways. Wouldn't hurt being its outside next to water. ( pipe leaking, rain water, etc.) I've seen some heat tape in pretty bad shape.
  28. Replies
    22
    Views
    1,302

    Don't work in rain.

    Don't work in rain.
  29. Replies
    39
    Views
    4,157

    Our older guys have already showed the new ones...

    Our older guys have already showed the new ones how to re-build them. We have a couple of tear down crews.
  30. Replies
    21
    Views
    18,260

    Tech Support--- 1-877-887-7263. Don't know how...

    Tech Support--- 1-877-887-7263.

    Don't know how much help u will get unless u work for Trane.
  31. Replies
    7
    Views
    1,146

    ok Tudormatt, Thanks

    ok Tudormatt, Thanks
  32. Replies
    10
    Views
    853

    Sounds like you need a CTI board. That will...

    Sounds like you need a CTI board. That will convert you from a dc to low voltage. It will run in test for 1 hr or until you cut power on and off.
  33. Replies
    5
    Views
    888

    Good luck! I've been with Trane for 16 yrs. now...

    Good luck! I've been with Trane for 16 yrs. now so i know it's hard to leave. Best place around here to work.
  34. Replies
    7
    Views
    1,146

    I don't know if they are turning them to far or...

    I don't know if they are turning them to far or what. The cover is tricky if your not use to it but I don't think they were trying to take them off. Does anybody know if you can get just knobs...
  35. Replies
    7
    Views
    1,146

    Trane's sen 01447

    Has anybody else been having problems with knobs braking off of the new style sensor trane is using on vav boxes? I've been changing about 2 a week.
  36. Replies
    8
    Views
    1,153

    Run into a RTHD doing the same thing today. Had...

    Run into a RTHD doing the same thing today. Had to add little oil 48 to let sensor go back wet and then chiller would start. Found solenoid vavle on the gas pump leaking refr. When solenoid would...
  37. Replies
    17
    Views
    1,865

    Yea, his a good guy to work for.

    Yea, his a good guy to work for.
  38. Replies
    17
    Views
    1,865

    Yep. That would be it. You work with that office...

    Yep. That would be it. You work with that office any?
  39. Replies
    12
    Views
    3,081

    We just use the York brand.

    We just use the York brand.
  40. Replies
    17
    Views
    1,865

    We are still a trane commercial franchise owned...

    We are still a trane commercial franchise owned office and we have gps (big brother) but it to keep up with us.
  41. Replies
    14
    Views
    2,374

    I always use new freon.

    I always use new freon.
  42. Replies
    159
    Views
    24,444

    Tranes a 100% better.

    Tranes a 100% better.
  43. Replies
    2
    Views
    638

    ok thanks hvacr.

    ok thanks hvacr.
  44. Replies
    2
    Views
    638

    Sabroe compressor help

    We are trying to give a price for a service contract on a plant but we have to include a price to rebuild (2) 12 cyclinder and (2) 16 cyclinder comp.

    We do alot of rebuilds on other type...
  45. Replies
    1
    Views
    606

    Sabroe compressor help

    We are trying to give a price for a service contract on a plant but we have to include a price to rebuild (2) 12 cyclinder and (2) 16 cyclinder comp.

    We do alot of rebuilds on other type...
Results 1 to 45 of 49