    Just make sure the pex has an oxygen barrier.

    Just make sure the pex has an oxygen barrier.
  2. Replies
    26
    Views
    4,643

    Hey chuck reading this months later I can barely...

    Hey chuck reading this months later I can barely understand what I said, let alone expect you too lol.

    The buffer tank is only heated when there is a call for heat.
  3. Replies
    26
    Views
    4,643

    You like to drain half the system with the tank...

    You like to drain half the system with the tank and have to fug around with air in the system?
  4. Replies
    34
    Views
    1,326

    You'll have to buy a new condenser rated for 17'...

    You'll have to buy a new condenser rated for 17' of line set
  5. Replies
    15
    Views
    988

    We'll if the sun burnt out tomorrow he'd be happy...

    We'll if the sun burnt out tomorrow he'd be happy with a grossly oversized furnace :D
  6. Thread: Ripped off

    by Joehvac25
    Replies
    20
    Views
    1,550

    I had a 1 or 2 month old makita cordless combo...

    I had a 1 or 2 month old makita cordless combo kit in my van. I had my doors locked like usual but I went to my van to get a book and didn't lock them back up. I live in a usually fine area. The next...
  7. You could have a filter drop with a 4" pleated...

    You could have a filter drop with a 4" pleated installed, more surface area, or have your duct work evaluated


    Sent from my iPhone using Tapatalk
  8. Replies
    4
    Views
    528

    I didn't read it all, way to long but a buffer...

    I didn't read it all, way to long but a buffer tank is made for an over sized boiler


    Sent from my iPhone using Tapatalk
  9. Replies
    15
    Views
    2,060

    There should be a low lp pressure switch in the...

    There should be a low lp pressure switch in the furnace that would cut it out, that's if it was installed. I've heard them say like 5-10%


    Sent from my iPhone using Tapatalk
  10. We don't answer DIY questions here but did you...

    We don't answer DIY questions here but did you mark the wires when you pulled it apart, and did you shut the power off before you took all of the wires off


    Sent from my iPhone using Tapatalk
  11. Call an Hvac person, sounds like a bad secondary...

    Call an Hvac person, sounds like a bad secondary hex. Sounds like you got your $400 worth out of that furnace :D


    Sent from my iPhone using Tapatalk
  12. All the boilers I've seen circulate water not air...

    All the boilers I've seen circulate water not air :D


    Sent from my iPhone using Tapatalk
  13. Sometimes you need to do what's best for them, if...

    Sometimes you need to do what's best for them, if you need to do some extra cleaning to make them safe or something work right you tell them you just have to do it.


    Sent from my iPhone using...
  14. Replies
    18
    Views
    1,398

    Sounds like a bad out door fan to me Sent...

    Sounds like a bad out door fan to me


    Sent from my iPhone using Tapatalk
  15. Replies
    5
    Views
    328

    Let me guess it's tripping the limit so your sure...

    Let me guess it's tripping the limit so your sure it's bad not doing its job :D


    Sent from my iPhone using Tapatalk
  16. Replies
    27
    Views
    3,339

    You obviously weren't the low bidder, nice work,...

    You obviously weren't the low bidder, nice work, well laid out
  17. What are your readings on low fire

    What are your readings on low fire
  18. The pressure would be equal on each side so no...

    The pressure would be equal on each side so no reason to flow. They would need a zone valve with a circulator
  19. That seems odd, I don't know if you would get...

    That seems odd, I don't know if you would get Enuf flow without a pump just from gravity
  20. Replies
    1,051
    Views
    84,181

    Looks like the future.

    Looks like the future.
  21. Replies
    24
    Views
    1,158

    It sure can damage the motor but maybe not this...

    It sure can damage the motor but maybe not this fast. I replace them regardless when I change a blower motor, just good practice I guess. He should test it to see if it is a problem and replace if...
  22. Replies
    24
    Views
    1,158

    From low to high the blower is already running,...

    From low to high the blower is already running, at start up it has to try to get spinning.
  23. Replies
    24
    Views
    1,158

    Did they change the capacitor at the same time

    Did they change the capacitor at the same time
  24. Replies
    8
    Views
    455

    Tracks are nice but useless in the summer, winter...

    Tracks are nice but useless in the summer, winter it kills lots of power. I drove a ranger with tracks so maybe a razr would would be better.

    My old rhino had 28 or 30" mud lites and she went...
  25. Replies
    37
    Views
    1,436

    Hell ya sportsman's paradise. I don't duck hunt...

    Hell ya sportsman's paradise. I don't duck hunt and I'm pretty sure my 5 and 3 year old don't either lol
  26. Replies
    37
    Views
    1,436

    It may cost more in gas than it's worth :D

    It may cost more in gas than it's worth :D
  27. Replies
    37
    Views
    1,436

    It really hurt me, someone bought my kids them...

    It really hurt me, someone bought my kids them fuggin duck calls :D
  28. Replies
    43
    Views
    1,612

    I was making an example sort of. The furnace is...

    I was making an example sort of. The furnace is oversized for the ductwork, not by itself
  29. Replies
    43
    Views
    1,612

    Not enuf duct work. If you ran It with zero duct...

    Not enuf duct work. If you ran It with zero duct as in no supply or return it would be fine. Add your most likely to small return and supply then it won't move enuf air. Its possible a higher blower...
  30. Replies
    43
    Views
    1,612

    Qwerty knows I have a t150 but it's set to the...

    Qwerty knows I have a t150 but it's set to the lowest firing rate possible.
  31. Replies
    43
    Views
    1,612

    Your prolly Looking at a complete redo if you...

    Your prolly Looking at a complete redo if you ever want it to work. I'm 2400 at 50K. It's -5 and I'm nice and warm with that.
  32. Replies
    17
    Views
    1,535

    I hear that all the time, same thing old janitrol...

    I hear that all the time, same thing old janitrol and they claim they asked for top of the line equipment. I want to say well the only guy who put janitrol in only had 1 choice lol
  33. Replies
    9
    Views
    633

    Who I'm sure delivers parts or something

    Who I'm sure delivers parts or something
  34. Replies
    9
    Views
    633

    He as in his Hvac friend

    He as in his Hvac friend
  35. Replies
    9
    Views
    633

    If it's the one on the inducer it usually means...

    If it's the one on the inducer it usually means it's over heating. He should pull it off and see if it has a missing disc. Some have them so they can use the same inducer on different size furnaces
  36. Replies
    17
    Views
    1,535

    I could have the heat back on in a day, a couple...

    I could have the heat back on in a day, a couple weeks is way off.

    People buy the cheapest equipment known to man and expect to get 30 years out of them :D
  37. Your cond unit is a painted surface

    Your cond unit is a painted surface
  38. If you've ever seen where an exhaust is hitting...

    If you've ever seen where an exhaust is hitting metal or or condensate leaks on the cabinet it rots right out. I found a hose clamp on a 9 month old furnace so rotted it broke while trying to snug it...
  39. I have seen condensate eat concrete within a few...

    I have seen condensate eat concrete within a few years. We seem to have lots of concrete mop sinks in basements and I have noticed some that have condensate pumped to them look pocky. I think small...
  40. Replies
    10
    Views
    919

    I'd call the installer back it should be under...

    I'd call the installer back it should be under warranty
  41. Silent night must = your dead :D

    Silent night must = your dead :D
  42. I hate them sensors

    I hate them sensors
  43. Replies
    24
    Views
    2,652

    I remember the low level days, wonder which panel...

    I remember the low level days, wonder which panel to take off and not know what the hell I was looking at. I remember if I got somewhere and was able to reset the furnace and get it running id GTFO...
  44. I personally don't care for him but kids will be...

    I personally don't care for him but kids will be kids and who cares
  45. Replies
    30
    Views
    1,903

    The board only powers one at a time so if black...

    The board only powers one at a time so if black is jumped to heat and cool it will only power the one speed, unless I read it wrong
  46. Replies
    143
    Views
    8,468

    6 months off and all the drugs you want?!

    6 months off and all the drugs you want?!
  47. Replies
    12
    Views
    895

    Here's a good test, will it hold the pilot on:...

    Here's a good test, will it hold the pilot on: yes = good
    No= bad.

    General rule for me is replace it if It looks bad, for $ and 5 minutes you saved a future call.
  48. I guess if you hold it by the motor and it's over...

    I guess if you hold it by the motor and it's over amping it will be hot but that's what calluses are for :D
  49. I'm not sure why anyone would drain a boiler with...

    I'm not sure why anyone would drain a boiler with a relief. If they get popped yearly like code states they usually don't have issues. Every boiler I do a state inspection on I have to pop the...
  50. That's the whole point, why wouldn't you pop it...

    That's the whole point, why wouldn't you pop it off, what happens when they are stuck shut or full of junk and won't pop off, we are there to make sure it's safe, not to say well I'm too lazy to...