  1. Replies
    9
    Views
    1,443

    Has anyone tried these Turbocor Magnetic Bearing...

    Has anyone tried these Turbocor Magnetic Bearing Compressors? Check them out Turbocor.com
  2. Replies
    3
    Views
    1,662

    Does anyone have any experience with an...

    Does anyone have any experience with an installation of a VFD (by Carrier) on a chiller "Carrier Mdl# 19DK-71-313CN 375ton. Has anyone had bad experience or has anyone had a good payback on their...
  3. Replies
    4
    Views
    1,168

    Anyone!? I need some materials for a TI buildout...

    Anyone!? I need some materials for a TI buildout using Wattmaster systems.
  4. Replies
    26
    Views
    2,869

    Orland, We don't understand what you're saying....

    Orland,
    We don't understand what you're saying.
    Please be more specific.
  5. Replies
    4
    Views
    1,168

    Is there anyone out there who knows of a West...

    Is there anyone out there who knows of a West Coast Contractor who deals with Wattmaster Controls, Prism,Orion?
  6. Replies
    11
    Views
    1,821

    Check with the installation literature and find...

    Check with the installation literature and find out if a deflector was supposed to be installed on the coil face and was left out or overlooked, but what is happening is that your exceeding the FPM...
  7. Replies
    21
    Views
    2,311

    You beat me by just a couple of seconds Maxster. ...

    You beat me by just a couple of seconds Maxster.
    Good site Huh!
  8. Replies
    21
    Views
    2,311

    Hey Doc, Try this, I hope it helps. ...

    Hey Doc,
    Try this, I hope it helps.
    http://www.carlylecompressor.com/TechnicalInfo/5FHInstall.htm
  9. Thread: Hot Tapping

    by pincheal
    Replies
    7
    Views
    2,210

    I had a 3" hot tap and used it as a bypass to...

    I had a 3" hot tap and used it as a bypass to change out a bad valve. We had to freeze the line on either side of the old valve to get it out. You have to totally stop the flow or the line will not...
  10. Replies
    7
    Views
    1,666

    Thanks for the input, I was leaning towards the...

    Thanks for the input, I was leaning towards the same direction. I can see where removing the vanes would cause turbulence and that makes sense to me.
    As for the VFD reference, we have a DDC system...
  11. Replies
    7
    Views
    1,666

    SWUA increase in Airflow

    I have a SWUA Trane package unit (40 tons) with airside Economizer and a water cooled condenser. I've recently added VFD control to the fan, and I'm considering removing the inlet vanes on the two...
  12. Replies
    14
    Views
    2,397

    Stryder, I've had really good luck with...

    Stryder,
    I've had really good luck with Stay-Brite #8 Silver bearing solder. The way I do it is get the fittings really clean with sand cloth or wire brush, I then use Stay-Clean liquid soldering...
  13. Replies
    12
    Views
    2,001

    You should of done all of the steps that you took...

    You should of done all of the steps that you took on the last compressor before you let the first compressor back into service. What were the pressures, amps, subcooling or superheat, temps, etc.....
  14. We drained and cleaned our cooling tower and when...

    We drained and cleaned our cooling tower and when we filled it was getting dark, and had left the door to the tower open. When the tower filled we fired it up and heard lots of noise and then it was...