Search:

Type: Posts; User: primmers

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    20
    Views
    905

    or reliable.I have a Little Ceasers that has a...

    or reliable.I have a Little Ceasers that has a norlake walkin, its on its 3rd controller in 5 years.
  2. Replies
    20
    Views
    905

    I agree with you UmmScott..the new digital stuff...

    I agree with you UmmScott..the new digital stuff sucks..
  3. Replies
    20
    Views
    905

    ^^^^ :) ^^^

    ^^^^ :) ^^^
  4. Replies
    8
    Views
    320

    I know thats what Im looking for ^^

    I know thats what Im looking for ^^
  5. Replies
    8
    Views
    320

    The gauges my supplier has doesn't have the...

    The gauges my supplier has doesn't have the adjustment screw…so I need to go direct to a manufacture.

    Ill use anything that I can adjust including a digital, but sometimes Theres not enough light...
  6. Replies
    8
    Views
    320

    Cant find anything on them..

    Cant find anything on them..
  7. Replies
    8
    Views
    320

    walk-in temperature gauge needed..

    My supplier can't get me what I need and i cant find any on e-bay..

    I want a 3" gauge that I can calibrate..

    Im being told that because Im at higher altitudes the one they've been selling me...
  8. Replies
    20
    Views
    905

    this one looks to be the one I need..thanks again...

    this one looks to be the one I need..thanks again pecmag…..
  9. Replies
    20
    Views
    905

    Thanks for the link pecmsg..good stuff but...

    Thanks for the link pecmsg..good stuff but nothing on the controller Im dealing with.
  10. Replies
    20
    Views
    905

    No the suction psi was 60 head was 200 The...

    No the suction psi was 60 head was 200
    The system will run for maybe 3 minutes and shut down.

    The flashing 135 is what bothers me right now..
  11. Replies
    20
    Views
    905

    Oh and happy 4th to those reading this

    Oh and happy 4th to those reading this
  12. Replies
    20
    Views
    905

    emerson electronic unit control problem..

    this thing flashes a 135 psi and goes off on P1 which is a
    suction probe failure..how can I by pass that probe?

    how can i be sure its not a controller failure?
  13. Replies
    25
    Views
    1,138

    Thank you guys…..much appreciated..

    Thank you guys…..much appreciated..
  14. Replies
    25
    Views
    1,138

    Square brush??? Got a link?

    Square brush??? Got a link?
  15. Replies
    25
    Views
    1,138

    thanks baub..ill try that cleaner….I got the...

    thanks baub..ill try that cleaner….I got the harvest to run over 5 minutes that helped a lot.
  16. Replies
    25
    Views
    1,138

    Its still "dirty"..but not as… I don't know...

    Its still "dirty"..but not as…

    I don't know what to use to get a iceman machine thats been neglected clean…
  17. Replies
    25
    Views
    1,138

    I took a wooden yard stick and stapled a piece of...

    I took a wooden yard stick and stapled a piece of scotchbrite to it and used it to "scrub" the evap..I made 4 loads of ice afterwards and I haven't gotten a phone call…

    please cross your fingers...
  18. Replies
    25
    Views
    1,138

    I let it run for a couple hours with lime away in...

    I let it run for a couple hours with lime away in it, the evap still has a build up on it, tomorrow I'm taking scotch brite and a stick to it..

    As i said ( think) its still dropping ice when it...
  19. Replies
    25
    Views
    1,138

    The float assembly is all the way bottom out..the...

    The float assembly is all the way bottom out..the screws are all the way to the top
  20. Replies
    66
    Views
    2,314

    Well Im glad the epa is watching out for us..

    Well Im glad the epa is watching out for us..
  21. Replies
    66
    Views
    2,314

    410a and then to propane..

    I bought a new ice machine (manitowoc) it runs on 410a…my sales guy said propanes coming..WTF?
  22. Replies
    25
    Views
    1,138

    Ive got a day and a half in this machine…some of...

    Ive got a day and a half in this machine…some of the ice doesn't fall off, I bought a new ice machine over the week end and was talking to them about this machine, they said the evaporator may be...
  23. Replies
    6
    Views
    555

    Yes the plumbers around here do plumbing and...

    Yes the plumbers around here do plumbing and heating which includes A/C..

    Amm yeah I know a little bit about freon…

    All went well, system is running great…
    I did this for a customer what has a...
  24. Replies
    6
    Views
    555

    I dont do A/C but……...

    I have a customer thats leaning on me to get his new A/C unit going, he and his son installed it and they want me to solder the ends and get it going..he said the condenser has enough freon (410) to...
  25. Replies
    6
    Views
    368

    Im still waiting for a email from Leer….

    Im still waiting for a email from Leer….
  26. Replies
    6
    Views
    368

    OMG..thank you soooooo much pecmsg…...

    OMG..thank you soooooo much pecmsg…...
  27. Replies
    25
    Views
    1,138

    This thing was a filthy mess….I disassembled the...

    This thing was a filthy mess….I disassembled the evap and spit shined all I could..the owner has been using CLR on it but not taking it apart.

    Im up to my ears in alligators at the moment, but the...
  28. Replies
    25
    Views
    1,138

    Ive never cleaned the machine, but will this...

    Ive never cleaned the machine, but will this morning..
  29. Replies
    6
    Views
    368

    No it has a "real" timer on it, but its bolted to...

    No it has a "real" timer on it, but its bolted to the electrical cover the cover that holds the t-stat.
  30. Replies
    25
    Views
    1,138

    thanks guys.

    thanks guys.
  31. Replies
    6
    Views
    368

    Hussmann/Leer ice merchandizer

    My competitor wired around a bad t-stat and made a mess out of the wiring, looks like a birds nest..

    I called hussmann and they referred me to Leer, they are looking but I don't have much...
  32. Replies
    25
    Views
    1,138

    Hoshzaki guys..

    Km-1600sr 51

    Alarm is 2 beeps..and the issues could be:

    open thermister…its good
    hgv not opening…it is
    low charge..has full sight glass
    bad compressor..?? makes good ice
    TXV leaking…how do...
  33. Replies
    12
    Views
    595

    WOW I ordered a cap tube and was sent 100' of the...

    WOW I ordered a cap tube and was sent 100' of the stuff..
  34. Replies
    13
    Views
    652

    slab looks good and even…ill try a bit thicker on...

    slab looks good and even…ill try a bit thicker on thursday..

    thanks guys
  35. Replies
    13
    Views
    652

    Ok…..

    Ok…..
  36. Replies
    13
    Views
    652

    yes its a manitowoc bin..the ice breaks up as its...

    yes its a manitowoc bin..the ice breaks up as its leaving the evaporator, and a cube or two will not let the "door" close until it melts..
  37. Replies
    13
    Views
    652

    Clean and harvest now is less than 2 minutes.

    Clean and harvest now is less than 2 minutes.
  38. Replies
    13
    Views
    652

    I had it thicker and it wouldn't drop,,so i...

    I had it thicker and it wouldn't drop,,so i worked my way down till it did drop.. the sheet looks good...
  39. Replies
    13
    Views
    652

    Indigo makes great ice…but….

    When the ice drops, some of the ice cubes break off falling and keep the curtain from closing…

    Ive got a good bridge…

    thoughts?
  40. Replies
    12
    Views
    595

    Has any one have any experience in. Changing a...

    Has any one have any experience in. Changing a cap tube on one of these boxes?
  41. Replies
    12
    Views
    595

    Thanks guys, the guy I bought my business is...

    Thanks guys, the guy I bought my business is working on this unit for a customer of his...he is a milk man now..Shaffer is out if business now how can I figure out the size of a new cap tube?
  42. Replies
    12
    Views
    595

    Top of the inside is cold but not the sides

    Top of the inside is cold but not the sides
  43. Replies
    12
    Views
    595

    Shaffer milk dispenser

    New compressor and 032filter..r12...cap tube was open on reassembly, low side is in a vacuum and has a high side off 155..90 ambient...I went to 180 on the high side. No luck, filter is warm suction...
  44. I leave notes

    I leave notes
  45. Replies
    48
    Views
    2,471

    icemeister it wasn't that nice..Ill see if I can...

    icemeister it wasn't that nice..Ill see if I can get a picture of it.
  46. Replies
    48
    Views
    2,471

    I had the line set out on the back steps to pre...

    I had the line set out on the back steps to pre solder the fittings and we just went ahead and soldered the liquid line (every foot or so) to the suction line..Im not sure how Hussmann had it...
  47. Replies
    25
    Views
    978

    I have a electronic super heat tool and it and my...

    I have a electronic super heat tool and it and my gauge set are 10* off.
  48. Replies
    3
    Views
    366

    ararams and icemeister

    These guys stuck with me with a problem I was having with a old Hussmann deli case..

    Came up with a possible solution, and it was the problem..

    Thank you guys soooo much, now I can get a decent...
  49. Replies
    48
    Views
    2,471

    ararams and icemeister it was the heat...

    ararams and icemeister it was the heat exchanger, I pulled the old one out fabricated a new and walla..it works now..

    thank you so much..
  50. Replies
    48
    Views
    2,471

    I know, and thats what I told my competitor..but...

    I know, and thats what I told my competitor..but he swears thats what he was told..

    I couldn't get a clear sight glass until i used up 40+ lbs..I know thats way too much…

    As I said Im more...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards