Search:

Type: Posts; User: Glenn Harrison

Page 1 of 14 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    309

    This is about the best deal you will find....

    This is about the best deal you will find. Otherwise they are about $1.00 each by the 10 pack
    ...
  2. It is also common to see Johnson Controls spark...

    It is also common to see Johnson Controls spark ignition modules with a normal flame signal of less than 1.0 microamps

    This is one reason I had to switch meters. I had a Fluke 902 and the microamp...
  3. The first generation of Carrier/Bryant hot...

    The first generation of Carrier/Bryant hot surface ignition control boards used a low voltage flame sensing circuit. This would create very normal flame currents of less than 1.0 microamps. So the...
  4. I have the AccuTools eL-320 gas leak detector (...

    I have the AccuTools eL-320 gas leak detector ( same company that makes the Blue Vac micron gauge) and that thing is compact, easy to use, and super sensitive and accurate. Plus the price is right.
  5. They were snug, but I had no problems screwing...

    They were snug, but I had no problems screwing them in.
  6. LED Lighted replacement plugs/sockets for power cords

    Not to long ago I broke the ground prong off my droplight plug. I've been bit too many times by electricity to take this lightly so I wanted to replace it right away.

    The only thing that sucked is...
  7. Replies
    1
    Views
    371

    Yes, excellent magazines. Even better, you can...

    Yes, excellent magazines.

    Even better, you can download all 15 of them for future reference.

    http://www.caleffi.com/usa/en-us/technical-magazine
  8. Replies
    162
    Views
    8,713

    I'm really liking the looks and sound of this....

    I'm really liking the looks and sound of this. The light weight module that can be left at the unit or carried around is nice, gives more options. Also makes it so the entire system can easily be...
  9. Replies
    162
    Views
    8,713

    Jim I had another thought. Could the iConnect...

    Jim I had another thought.
    Could the iConnect have the ability to read and display two sets of high side and low side pressures and temperatures, and display them as two separate calculations, just...
  10. Replies
    162
    Views
    8,713

    I have to admit when the iManifold came out I was...

    I have to admit when the iManifold came out I was skeptical. Now after all the reviews and continued updates, I'm impressed and intrigued. The estimated airflow feature looks awesome.

    However, I...
  11. I have a couple of the Vapor Vue's and I have...

    I have a couple of the Vapor Vue's and I have used the Imperial Kwik Charge also.
    The Vapor Vue does NOT flash the refrigerant very well, it doesn't have a small enough orifice in it. If you put...
  12. Johnstone #'s B16-902 B16-903 B16-904 ...

    Johnstone #'s
    B16-902
    B16-903
    B16-904

    http://catalogs.johnstonesupply.com/4036_john_205/full.asp?page=1108#catalog
  13. Replies
    92
    Views
    4,810

    Any tool I have found was left by accident or...

    Any tool I have found was left by accident or lost on the job, NEVER left there on purpose.

    I have also returned many items to technicians, in a couple of cases techs that work for competitors...
  14. Replies
    8
    Views
    472

    I've used mine for checking incoming power on new...

    I've used mine for checking incoming power on new units. "R" Right rotation means the phases are wired correctly, "L" left rotation means 2 legs are switched and rotation will be reversed from what...
  15. Replies
    92
    Views
    4,810

    My best find was a Ridgid 18" pipe wrench. Found...

    My best find was a Ridgid 18" pipe wrench. Found it outside in the bushes next to a condenser. Cleaned it up and put a couple of coats of paint on it and still use it many times every year.
    Others...
  16. Replies
    16
    Views
    1,137

    I bought Slicklock hasps and covers for the side...

    I bought Slicklock hasps and covers for the side and back doors. Then I ordered Hockeypuck locks with "MultiLock" cylinders in the them. Multilock cylinders are almost pick and bump proof. The...
  17. Replies
    44
    Views
    3,482

    Internet ventures, probably not. I'm all in...

    Internet ventures, probably not.
    I'm all in favor of supporting local business when the services/product I want is available locally.
    However, in this case I am specifically referring to Digicool...
  18. Replies
    44
    Views
    3,482

    I have no idea about the Cooper's, but I find the...

    I have no idea about the Cooper's, but I find the Digi's are easy enough to work with, one hand to hold the probe where you want it, and the other to pull and wrap the Velcro.
  19. Replies
    44
    Views
    3,482

    I'm very happy that Doug made an agreement with...

    I'm very happy that Doug made an agreement with UEI to sell more of his product.

    I also don't know about anyone else, but I'm personally in favor of as much of my money going directly to DIGI...
  20. Maybe those are the charts I thought I saw. More...

    Maybe those are the charts I thought I saw. More importantly those will help demonstrate the point I'm trying to make. Thank you.
  21. I understand that there is a lot of factors...

    I understand that there is a lot of factors involved, so there are no exact numbers. I could swear at one time I saw in one piece of Appion literature that there was some kind of a chart or table...
  22. Appion Chris-P Didn't Appion have a chart at...

    Appion Chris-P

    Didn't Appion have a chart at one time that listed the CFM that could be moved through different sizes of the same length of hose for comparison?
  23. Replies
    3
    Views
    301

    I've had one since it came out. Great tool, makes...

    I've had one since it came out. Great tool, makes calculating charge on cap tube/piston systems easy. Also great for those too much/too little humidity calls.

    Just don't put too much pressure on...
  24. Replies
    14
    Views
    663

    How about using another manifold on the outlet of...

    How about using another manifold on the outlet of the machine. Middle Yellow hose to machine, red hose to one tank, blue hose to another tank. Then you could fill 2 tanks at the same time, or fill...
  25. There's only two ways to know: 1: Test the...

    There's only two ways to know:

    1: Test the repaired unit against another unit to see if readings match closely.

    2: Invest in calibration equipment and gasses to test units after repairs. If...
Results 1 to 25 of 336
Page 1 of 14 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine