  1. Replies
    41
    Views
    3,023

    Advanced Response, Only a HO but sounds like...

    Advanced Response,

    Only a HO but sounds like pulling a pin and running on first stage is way to go. Will give it further thought and do some research. Thanks so much.
  2. Replies
    41
    Views
    3,023

    Kind of dark in here right now but perhaps the...

    Kind of dark in here right now but perhaps the light will come on. Thanks for all responses and willing assistance.
  3. Replies
    41
    Views
    3,023

    According to printout from manual, I am only able...

    According to printout from manual, I am only able to get to 915cfm with single stage. Oh....perhaps D for cool tap and D for adjust tap?
  4. Replies
    41
    Views
    3,023

    With pins set on cool tap on D and adjust tap on...

    With pins set on cool tap on D and adjust tap on C provides 915cfm on high and 495 on low. Since it is single stage, I assume the low setting of 495cfm is not available.
  5. Replies
    41
    Views
    3,023

    Single stage AC. If I had a two stage, I could...

    Single stage AC. If I had a two stage, I could get CFM down to around 400 very easily. When this unit goes, I will replace with two stage. Must I replace with a York unit or do I have options?
  6. Replies
    41
    Views
    3,023

    PIXUC16V07501

    PIXUC16V07501
  7. Replies
    41
    Views
    3,023

    York Diamond 95 Ultra with VS 2 stage gas heater...

    York Diamond 95 Ultra with VS 2 stage gas heater circa 2002.
  8. Replies
    41
    Views
    3,023

    It is VS blower but again 915 is lowest setting...

    It is VS blower but again 915 is lowest setting using pins inside unit. This is a single stage AC unit although the heat is two stage.
  9. Replies
    41
    Views
    3,023

    Do not have the expertise to check pressures,...

    Do not have the expertise to check pressures, load, etc. so will likely be safe setting it the 900 cfm. Or at least, I hope so. Also just double checked and lowest setting is 900 cfm so will have...
  10. Replies
    41
    Views
    3,023

    Right. But not sure if the CFM was set to coil...

    Right. But not sure if the CFM was set to coil or condenser. At an rate, now set to 900 CFM so will keep an eye on humidity control.
  11. Replies
    41
    Views
    3,023

    I appreciate the response. Just a few minutes...

    I appreciate the response. Just a few minutes ago decided to set the VS blower to 900 CFM and watch RH movement.
  12. Replies
    41
    Views
    3,023

    Residential CFM/AC

    Outside unit is 2 Ton but coil is 2 5 Ton. What would the recommended CFM be for maximum humidity control? Presently set at 1000 cfm.
  13. Replies
    0
    Views
    308

    Bryant FV4 VS Filter

    The Bryant uses a hogs hair filter in a size that is not compatible with any commercially available 1" filter. Other than having a custom frame made and then periodically purchasing the inserts, is...
  14. Thread: Kool Cap

    by tompass
    Replies
    12
    Views
    1,919

    Well Gunny, that about sums it up.

    Well Gunny, that about sums it up.
  15. Thread: Kool Cap

    by tompass
    Replies
    12
    Views
    1,919

    Thought so. Thanks.

    Thought so. Thanks.
  16. Thread: Kool Cap

    by tompass
    Replies
    12
    Views
    1,919

    Kool Cap

    Does anyone have any info on this item. It sits on top of heat pump and "blows" upward when fan is running and then lays down on top of unit supposedly to protect motor from getting constantly...
  17. My experience that there are many good...

    My experience that there are many good professional HVAC guys and techs out there but there are also some lazy ones. The young man that they sent out to correct some problems with my new install had...
  18. It is likely in the manual. Have to enter...

    It is likely in the manual. Have to enter program mode and follow directions.
  19. Replies
    7
    Views
    493

    I ordered some pleated material from air sponge. ...

    I ordered some pleated material from air sponge. Will have to cut and fit to frame.
  20. Replies
    7
    Views
    493

    Isn't hammock spun fiberglass same as inexpensive...

    Isn't hammock spun fiberglass same as inexpensive bue $1 filters? Is present hogshair filter better than cheap disposable filters?
  21. Replies
    7
    Views
    493

    So what would the recommended material to be used...

    So what would the recommended material to be used in this frame? Pleated media?
  22. Replies
    7
    Views
    493

    Hammock Filter Material

    Recently purchased a custom made aluminum frame filter with screen and hinged sides. Am I correct in assuming that the direction of air flow should be first through the filter material and then...
  23. Replies
    2
    Views
    999

    Consider the 265ANA and FV4 variable speed...

    Consider the 265ANA and FV4 variable speed handler with preferred humidistat with outdoor sensor.
  24. Replies
    13
    Views
    4,965

    Interesting that the washable filters are...

    Interesting that the washable filters are standard on Bryant VS air handlers.
  25. That info is availavble on their web site. Just...

    That info is availavble on their web site. Just go to menu on left side of page where it says controls. Then select the Preferred stat. That page will have option for documentation and those...