  1. Replies
    12
    Views
    887

    The draft motor part # is Fasco 70920238 or...

    The draft motor part # is Fasco 70920238 or Trane # D342097P01. It threw me off as it looks like a regular shaded pole motor but had an extra red lead that my small mind thought was low speed. (2...
  2. Replies
    12
    Views
    887

    Update, I was able to get more information on...

    Update, I was able to get more information on this unit. Turns out the draft motor is DC so it needs to be ohmed out like a 3 phase motor. Should read 14-17 ohm lead to lead. I was thinking it was a...
  3. Replies
    12
    Views
    887

    TRANE won't start draft inducer

    Trane TDH2C100A9V4VAB will not start the draft motor. Getting a pressure switch open fault. I hear what sounds like a relay clicking on the board but no power to the draft motor. Anyone run into...
  4. Replies
    3
    Views
    451

    The unit had a fan motor failure and it got so...

    The unit had a fan motor failure and it got so hot it melted the wire harness that runs above the blower assembly which includes the motor wires and the aux limit and main limit wires. None of the...
  5. Replies
    3
    Views
    451

    Heating hgh limit test for package unit

    Working on a Tempstar PGC048K080A and wanting to test the high limit switch. I put a K probe right next the the L130-20 AUX LIMIT which is the highest in the cabinet (except for roll out switch)...
  6. Replies
    2
    Views
    418

    Lennox G51MP Pressure switch problem

    I've got a customer with a Lennox G51MP furnace mounted horizontally and the lower pressure switch starts chattering (open close open close)after about 15 minutes of operation. I suspect it may not...
  7. Thanks everyone. Great info!! I live in a small...

    Thanks everyone. Great info!! I live in a small town and the parts house is 30 miles away. I ended up needing to go for something else and just picked up the 1/4 hp motor. Thanks Mucho!!
  8. Using 1/3 hp instead of 1/4 hp any problem?

    On a Bard wall mount heat pump, unit has a bad condenser fan motor. The existing motor is 1/4 hp. Is there a problem with replacing it with a 1/3 hp? ( don't have a 1/4 in stock) Thanks
  9. Replies
    1
    Views
    179

    GE PROFILE HAS SLOW ICE PRODUCTION

    I have a customer with A GE Profile TPX21PRXD-WW that has started producing ice very slowly. The ice maker model # WR30X10061 that is in the unit was a replacement about 6 years ago. I had a...
  10. Replies
    7
    Views
    538

    Great! when configuring, iHarmony , the AHC and...

    Great! when configuring, iHarmony , the AHC and outdoor unit, are their any particular things that are commonly missed by the installer? Air balance etc? Can you suggest anything to be careful about?
  11. Replies
    7
    Views
    538

    Thanks, So I should be looking at a iHarmony...

    Thanks,
    So I should be looking at a iHarmony installation manual? ( which I cant find )
  12. Replies
    7
    Views
    538

    iComfort with Harmony III question

    I'm looking at the Harmony III zoning system installation manual and am considering using a iComfort communicating thermostat for zone 1 and iharmony for zones 2&3 ( 3 zone total) but don't see the...
  13. TRANE YCX048 Coding "flame sensed with gas valve off:

    Have been getting this diagnostic code and not really sure how to proceed with diagnosis. Unit runs and heats ok. Burners look good and clean. Anyone come across this before?
  14. Replies
    4
    Views
    894

    Thanks glennac, When you say round duct, do you...

    Thanks glennac,
    When you say round duct, do you mean rigid or alumaflex ?
  15. Replies
    4
    Views
    894

    Air flow question

    Checking out a American Standard unit 2YCX3060 for poor performance. Found some air flow problems. The unit has 2 floor return grills that have 10" duct pipe. The filters are laying right over the...
  16. Filter shell has small weld leak / repair ideas requested

    Hi everyone,
    I found a small leak in a suction filer shell and am wondering what might be the best way to repair it. It's a BTAS-313-V brass suction filter shell. The leak is at the bottom of the...
  17. Replies
    13
    Views
    897

    I can borrow a flow hood from PG&E training...

    I can borrow a flow hood from PG&E training center to read cfm. A static pressure reading could also work provided I can get a chart from the furnace mfg. My airflow check so far has been to make...
  18. Replies
    13
    Views
    897

    The charging chart is gone, rotted out, so is the...

    The charging chart is gone, rotted out, so is the condensing unit identification plate. The condenser is a older unit, the A coil and furnace are new. The compressor is a Copeland ZR36K3 Rated at...
  19. Replies
    13
    Views
    897

    Would larger increase suction?

    Would larger increase suction?
  20. Replies
    13
    Views
    897

    Would a smaller size piston increase suction...

    Would a smaller size piston increase suction pressure? The evaporator TD was 17F. No temp diff across liquid filter, No difference in pressures with air filter out.
  21. Replies
    13
    Views
    897

    Refrigerant metering problem

    A customer has their furnace and A coil replaced this last winter and wanted the air conditioner charge checked for summer operation. Its a R-22 3 ton system. The A coil is a R-22 AllStyle non-TXV...
  22. Replies
    9
    Views
    1,268

    @Dallas Duster-- this unit has a single internal...

    @Dallas Duster-- this unit has a single internal pump.

    What we have found --- even though the water fill valve was open, it was not filling the system We manually added water by removing one of...
  23. Replies
    9
    Views
    1,268

    Nuclrchiller, Yes they are about 3 ft. away from...

    Nuclrchiller,
    Yes they are about 3 ft. away from the unit. I reversed the gauges because thought the return gauge was broken but it is not. I cleaned and flushed the taps.
  24. Replies
    9
    Views
    1,268

    I found the domestic water valves are open to the...

    I found the domestic water valves are open to the system. There is a back flow preventer then a pressure regulator, the valves are all open. I don't know why they are open or if the should be. The...
  25. Replies
    9
    Views
    1,268

    Carrier 30RA chiller return water pressure

    Hello,
    I have a customer that has a chilled water system for a school building that has a flow error code. The system has a supply water pressure of 35 psi and the return pressure is about 0-5psi....
  26. Replies
    3
    Views
    1,755

    Just wanted a second opinion. There is no...

    Just wanted a second opinion. There is no readable wiring diagram on the unit. One thing I didn't mention, when I first got there and turned on the unit after it had been off all night, it clicked a...
  27. Replies
    3
    Views
    1,755

    Rheem RGAA-08EC gas valve issue

    I was on a no heat service call this morning (Sat)on this Rheem unit. I was finding that the pilot would light and stand for 20 sec. or so and then I would hear solenoid clicking, the pilot would...
  28. Girgling noise at unit start-up and shut down

    Customer has 2 story house, furnace and A coil in attic horizontal. Customer hears girgling when it starts and shuts off. Lennox with TXV. Is this normal ? If not what can be done to keep it quiet?...
  29. Would a evaporative cooler still be the best MUA?...

    Would a evaporative cooler still be the best MUA? I don't know if they make them that small 1200 cfm? The area where the restaurant is located is on a river edge and the humidity ranges from 26% on...
  30. Restaurant kitchen exhaust hood / make up air problem

    I have a customer that has a kitchen that is open to the dining area and the stove area has a 1500 cfm exhaust blower. Next to the hood they have a 5000 cfm evaporative cooler running at full speed...
  31. I've installed 5 Fugitsu systems and they all...

    I've installed 5 Fugitsu systems and they all work great. Customer support is also excellent.
  32. Replies
    20
    Views
    2,465

    Are you checking/replacing the start contactor?...

    Are you checking/replacing the start contactor? /// What barbar said?
  33. Replies
    24
    Views
    9,479

    I just installed 2 Fugitsu units. They are...

    I just installed 2 Fugitsu units. They are awesome! The bigger unit is a ASU15RSL2 and is 21 SEER the smaller was 25. All the Fugitsu units I have installed work great and they are a little less...
  34. Replies
    6
    Views
    1,419

    410A evaporator coil conversion to R-22

    Has anyone had any experience with a 410A coil TXV conversion to R-22? I have been told that a 036 coil is to small for a R-22 036 condenser. If that is true would you use a bigger coil like a 048...
  35. Replies
    1
    Views
    553

    Found it .... Southwire EZ-IN Mini Split Cable

    Found it .... Southwire EZ-IN Mini Split Cable
  36. Replies
    1
    Views
    553

    Mini Split communication cable

    Hello, I was trying to find the cable mfg that I saw advertising on this site. The electrical cable was for mini-split unit communication. Did anybody happen to write it down? Thanks for any help.
  37. Replies
    21
    Views
    4,351

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  38. Replies
    4
    Views
    1,196

    Siemans 24v contactor coil keeps failing

    Hi, I have a problem with these 75 amp contactors. Last week I found both compressor contactor coils shorted. ( 2 compressor unit) I find it odd that they would both go exactly at the same time. The...
  39. ORI -- Opens on Rise of Inlet pressure ,, ORD...

    ORI -- Opens on Rise of Inlet pressure ,, ORD -- Opens on Rise of Differential pressure
  40. Replies
    21
    Views
    3,242

    Sometimes I try to "weigh out" the charge when...

    Sometimes I try to "weigh out" the charge when recovering. If you can find a nameplate charge it gives an idea. I'm sure the dirty condenser didn't help anything.
  41. Replies
    21
    Views
    3,242

    High discharge temp, over charge?

    High discharge temp, over charge?
  42. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  43. Replies
    9
    Views
    1,535

    Yes the unit I'm working on is running. I have...

    Yes the unit I'm working on is running. I have 50lb recovery tanks. Could I attach a line from the unit liquid reciever to the liquid tank port and a line from a suction port to the tank vapor port...
  44. Replies
    9
    Views
    1,535

    Sorry, I'm wondering if there is a recovery...

    Sorry,
    I'm wondering if there is a recovery machine that would be able to remove 100lb quickly.
  45. Replies
    9
    Views
    1,535

    100+pound recovery machine?

    Could anyone recommend a setup for recovering a large amount of refrigerant quickly? I currently use a Promax RG6000 which is good but very slow.

    Thanks for any ideas
  46. The unit does have a reciever M/N UR108 I agree...

    The unit does have a reciever M/N UR108 I agree the reciever should be storing the extra refrigerant and not the condenser. It appears that the liquid is not being let out of the condenser when it...
  47. ORI-ORD setup -- 350 lb head, 50 lb suction Problem

    Anyone have problems with this set-up before. I have clean filters liquid and suction. This is circuit B on a SA30 Desert-Aire heat recovery system serving a natatorium. Unit pressures are normal in...
  48. S8610U has bleed resistor from TH-W to ground.

    I found this in a RUUD URGG-05E24JKR unit today. Unit works fine, (after I replaced the rusted out burners) just wondering why the resister is there. Can't find any foot notes on it. Anyone know...
  49. Replies
    6
    Views
    2,210

    Bangor BFGC-5 Freezer case

    Could I please get a copy of that booklet? I have a customer with lighting problem and was hoping to find a wiring diagram or any imformation possible.

    Thanks
    Kirk
  50. Replies
    2
    Views
    936

    GOODMAN GMP-075-3 Ignitor question

    I have a customer that has this unit and HSI comes on 3 times before the gas valve opens gas fires and then it stays on. No fault codes. Any idea why its not firing the firts time th HSI comes on?...
Results 1 to 50 of 50