Search:

Type: Posts; User: INTECHBILL

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Prep Tables

    by INTECHBILL
    Replies
    26
    Views
    4,025

    Be sure to check the condensate drain .. ! The...

    Be sure to check the condensate drain .. ! The situation I've seen the line is very small plugs up & then the fan throw the puke water everywhere !

    :ghug:
  2. Replies
    4
    Views
    2,317

    Can you open the link to the web site ? Tried but...

    Can you open the link to the web site ? Tried but could find it !
  3. Replies
    47
    Views
    6,017

    Thats right many things can happen related to...

    Thats right many things can happen related to sub-cool & super-heat , if you fully understand heat principles .., even you release heat / over 80% on top of your head ... Then why the compressor...
  4. Replies
    47
    Views
    6,017

    Have you not worked on Semi-Hermetic Low Temp...

    Have you not worked on Semi-Hermetic Low Temp Commercial applications -- If the compressor creates heat by "heat of compression" and can't get rid of the heat -- then what happens ! OHHH ! :argue:...
  5. Make certain with whatever you do in PHOENIX that...

    Make certain with whatever you do in PHOENIX that the equipment is sized correctly - Especially for the upcoming summer .. ! Use the right contractor and make certain they have experience with R-410a...
  6. Replies
    47
    Views
    6,017

    expl # 1 If I'm not mistaken if the compressor...

    expl # 1

    If I'm not mistaken if the compressor is loaded with oil , the oil will hold heat and there you have it yes?

    Expl #2

    If the outdoor coil is restricted the compressor will overheat -...
  7. Both are very good systems .., Make certain that...

    Both are very good systems .., Make certain that the equipment is sized correctly any contractor should be able to offer a Manual J - Heat-Loss / Heat-Gain calculation & more than likely it will be a...
  8. Replies
    47
    Views
    6,017

    This happens whenever the compressor absorbs heat...

    This happens whenever the compressor absorbs heat instead of rejecting it ! Many causes ! Read the book ..
  9. Replies
    10
    Views
    946

    I think it might be a very good idea to learn how...

    I think it might be a very good idea to learn how to spell first --- What's pahse >>>?

    :couchhide:
  10. Replies
    14
    Views
    943

    :patriot: It's here ! So How ya feel ? ...

    :patriot: It's here ! So How ya feel ?

    :patriot:
  11. Replies
    0
    Views
    479

    ** >> NEW EPA CERTIFICATION

    :rules: Beginning next month there will be a new EPA Requirements & Certification for lead paint for the HANDYMAN ! :patriot: Just another way to phase out the handyman as well as a step closer...
  12. Replies
    23
    Views
    1,931

    Depending on what size the system is & with your...

    Depending on what size the system is & with your insight mentioned , sounds like a fraction system that holds a very small amount of refrigerant ... an ASHRAE engineer told me once that the smaller...
  13. Replies
    32
    Views
    1,561

    Much easier for service .., back in the day we...

    Much easier for service .., back in the day we would have them on an equipment check list & we'd stop by their for a smoke & give all the equipment a quick peek..:angel:

    :patriot:
  14. Replies
    32
    Views
    1,561

    Some city codes do not permit water cooled...

    Some city codes do not permit water cooled systems :rules:

    :oops:
  15. Replies
    32
    Views
    1,561

    It may be in your best interest to get the quote...

    It may be in your best interest to get the quote indoors do to the fact the units would be smaller & cost less money to operate - An extraction fan would be incorporated to the mechanical room
  16. Replies
    6
    Views
    1,956

    If your a good tech .. You should know the...

    If your a good tech .. You should know the difference between a Integrated and Non-integrated defrost board .. then explain how to initiate and terminate a defrost simulation & why you should not use...
  17. Replies
    2
    Views
    1,433

    Dealer 3 is looking at the job in more detail -...

    Dealer 3 is looking at the job in more detail - Just have him back his work with a Manual J Heat-gain / Heat-Loss report ,, To make certain the equipment is correctly sized & have him offer more...
  18. Replies
    6
    Views
    1,956

    I believe by now you realize the problem is not...

    I believe by now you realize the problem is not the defrost board & Believe it or not sometimes a heat-pump system will in fact have ice on the outdoor coil -:rules: Make certain the defrost board is...
  19. Replies
    14
    Views
    943

    HEY EVERYONE -- CAN'T YOU GET THE PICTURE HERE --...

    HEY EVERYONE -- CAN'T YOU GET THE PICTURE HERE -- HE WAS PAID OFF 4 HIS VOTE THEN WALKED AWAY WITH HIS PART OF THE CUT :angel: ---- OPEN YOUR EYES ! :patriot: & PROTECT OUR FREEDOM !

    :rules:
  20. Replies
    7
    Views
    1,616

    Your always gonna be looking for that one BIG job...

    Your always gonna be looking for that one BIG job dude .. If you want to stay solo - It's a TWO (2) part system !:rules:

    1- ADVERTISING- ( Word of mouth & Newspaper )
    2- MONOPOLY - ( What you...
  21. Try to be a bit more blunt with your insight -...

    Try to be a bit more blunt with your insight - Without writing a book - , variable speed , gas, electric Resistance, or Heat-pump - Size of air ducts and more issues surrounding humidification &...
  22. Replies
    655
    Views
    19,504

    :rules:WHAT - We Fear our government - Now We...

    :rules:WHAT - We Fear our government - Now We need to fear a Church !

    :pop:
  23. Thread: Avatars

    by INTECHBILL
    Replies
    18
    Views
    984

    BASICALLY but kinda extreme insight ! :angel: ...

    BASICALLY but kinda extreme insight ! :angel:

    Remember " Don't Drink and Drive " & Always " Protect our Right to Bare Arms "..

    :anyone:
  24. Replies
    14
    Views
    943

    I sure hope soooo! :anyone:

    I sure hope soooo!


    :anyone:
  25. Replies
    9
    Views
    2,240

    GOOD idea sometimes it's better to just walk away...

    GOOD idea sometimes it's better to just walk away !
  26. Replies
    16
    Views
    1,751

    Technically were speaking of POE oil contents &...

    Technically were speaking of POE oil contents & removal of air, moisture & dirt !

    :anyone:
  27. Replies
    14
    Views
    943

    >>* NATIONAL HEALTH CARE *

    Rumor has it that some of our cabinet members are being set- up and forced to resign so everyone may pass the new health care for the nation --- Let's see what Robo Teq has to say -- I have some...
  28. Replies
    9
    Views
    2,240

    It's legal in some places for air conditioning...

    It's legal in some places for air conditioning excluding any type of humidification ; seal it first then insulate the inside with some good quality glue once it's nice and clean & dry.. At least it...
  29. TOTAL LINE

    TOTAL LINE
  30. Replies
    16
    Views
    1,751

    First off what's FREON and rumor has it that on...

    First off what's FREON and rumor has it that on commercial refrigeration as box temp goes down , pressures go down.. An ASH RAE engineer told me once that pressures are used to check for leaks ...
    ...
  31. Replies
    17
    Views
    859

    Many people in the world today enjoy putting God...

    Many people in the world today enjoy putting God in their Box -- There are many examples " Observation of Sunday as a legal duty " ( 321 A.D. ) -Image worship (787 A.D.) - Changes in God's law of...
  32. Replies
    11
    Views
    1,549

    If we buy can we still keep the product line or...

    If we buy can we still keep the product line or move it to another state ?
  33. Replies
    28
    Views
    1,764

    Great rifts dude ! I like just about all of it,...

    Great rifts dude ! I like just about all of it, I've had my facebook for a few weeks and I'm still playing with it, I need to learn more about the program so I can add tabs for my songs and videos.....
  34. You might want to consider the recent post "...

    You might want to consider the recent post " Carrier Infinity Question " before you finalize your motions...


    :oops:
  35. Replies
    11
    Views
    927

    Why don't you give some advise to the guy that...

    Why don't you give some advise to the guy that wants to install one -- Advice replacing my 14 year old Heat Pump -- after the aggravation and extra expense.
  36. GREAT UNIT check out the spec's on the website --...

    GREAT UNIT check out the spec's on the website -- better than others !

    A Total Line control / Thermostat will give you more control over your system.. & knot the service tech..that doesn't live in...
  37. Replies
    10
    Views
    6,134

    :couchhide: With your electrical bill somewhat...

    :couchhide:

    With your electrical bill somewhat around 1K $ - it's astonishing.., I had a home somewhat as your describing and our problems were contributed to the upstairs been unsupervised at the...
  38. Replies
    10
    Views
    6,134

    Payne and Carrier are basically the same unit -...

    Payne and Carrier are basically the same unit - Like Chevrolet & GMC for example.. Dallas, TX. is a very good place for a 2 stage, variable speed, Heat-pump system with axillary heat . I've installed...
  39. Good choice of equipment and air quality is very...

    Good choice of equipment and air quality is very important - electronic filters were used in history but the newer media filters are improving greatly, electrostatic technology is improving to...
  40. Armstrong is the same as Lennox , they only...

    Armstrong is the same as Lennox , they only consider it a lower quality in production .. get one more estimate on different equipment and include a Heat loss - Heat gain estimation before you make...
  41. First of all - What's a 2 speed HP ? Second -...

    First of all - What's a 2 speed HP ?
    Second - What's a single speed unit ?

    :oops:

    There are many advantages with the 2 stage system , including a great warranty... The air handler can be...
  42. The only different in these units are a built in...

    The only different in these units are a built in solenoid valve within the compressor .. Almost all of the air handlers today are variable speed - a 2 stage will give you more savings, more...
  43. Replies
    5
    Views
    951

    What safety is opening ? Whenever I replaced the...

    What safety is opening ? Whenever I replaced the exchanger on this unit it included new HTL's that were auto reset & were hotter than the originals - Is the IFM operating normally - What was the main...
  44. Replies
    5
    Views
    951

    Good Unit whenever it.s working right it's a real...

    Good Unit whenever it.s working right it's a real kicker - Check the following -

    - Make sure your non-ox baffles or screens are completely in place - I used to remove
    them to get a better...
  45. Replies
    5
    Views
    4,355

    Depending on the age of the system - they were...

    Depending on the age of the system - they were bought out by Goodman a few years back - I haven't seen any system above a 10 seer
  46. Replies
    4
    Views
    1,455

    1st stage = 37,000 btu 2nd stage = 52,000 btu...

    1st stage = 37,000 btu
    2nd stage = 52,000 btu

    No they don't operate at the same time - when second stage makes , first stage breaks., this is done do to plumbing and back pressure issues.. The...
  47. Replies
    19
    Views
    2,142

    Idiot Harvest Assist motor gettin stuck in freeze...

    Idiot Harvest Assist motor gettin stuck in freeze cycle ---- and the 2 dollar radio shack micro switch not energizing the defrost circuit .... ! NEXT EXAMPLE PLEASE


    I bought a pencil at a...
  48. Replies
    19
    Views
    2,142

    ICEOMATIC - The famous harvest assist motor /...

    ICEOMATIC - The famous harvest assist motor / micro switch problem - your lovinit !
  49. NOOO ! They do NOT operate the same the two stage...

    NOOO ! They do NOT operate the same the two stage operates at 40% of it's capacity at first stage , Thus creating a more comfortable environment - You can actually take the 2 stage unit and operate...
  50. Very good choice just make certain that the TXV's...

    Very good choice just make certain that the TXV's are installed sometimes they are in different packaging - If these are not installed you most certain will wash out your compressor on the 2 stage...
Results 1 to 50 of 259
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event