  1. Replies
    6
    Views
    907

    Visio is your best bet, I find it much...

    Visio is your best bet, I find it much easier/quicker to work with than AutoCAD if you've had no AutoCAD experience.
  2. Replies
    3
    Views
    608

    Instead of syncing, have you tried a download? ...

    Instead of syncing, have you tried a download?

    Might also think about flashing the APB file, which I think will clear the program, though I'm not 100% on that.
  3. Replies
    1
    Views
    890

    Are you running it in AUTO changeover, or HEAT or...

    Are you running it in AUTO changeover, or HEAT or COOL mode? If you're setting HEAT or COOL mode yourself, it does not matter how close your set points are. If you're running it in AUTO change over,...
  4. Replies
    12
    Views
    1,256

    A Tridium based system is your best bet. Make...

    A Tridium based system is your best bet. Make sure you insist that the JACE controllers that are installed are open, in other words licensed like this:

    accept.station.in="*"...
  5. Replies
    3
    Views
    960

    I used the Dynasonic on one job on CHW and CW...

    I used the Dynasonic on one job on CHW and CW systems. They weren't very stable. Worked one minute, then stopped working the next. However, it was an existing system, the pipe was probably not smooth...
  6. Thread: lost sensor

    by volfman
    Replies
    5
    Views
    504

    What kind of sensor was it, and what model...

    What kind of sensor was it, and what model carrier bridge?

    Are you just using the CCN software, or is there an i-Vue on site?
  7. Replies
    4
    Views
    553

    What version of Niagara?

    What version of Niagara?
  8. Replies
    10
    Views
    924

    I agree with scrooloose - DPTE-6 in your drawing...

    I agree with scrooloose - DPTE-6 in your drawing is what you're controlling to. The OA and RA dampers are running off the same signal (action reversed though), so as the RA closes, you're going to...
  9. Replies
    4
    Views
    480

    Any luck with this code? My supplier is telling...

    Any luck with this code? My supplier is telling me its not possible, but that's sort of hard for me to believe.
  10. Replies
    4
    Views
    480

    I realize it loads all the data, but didn't think...

    I realize it loads all the data, but didn't think 8 AHU is too much. In any case, I think that'd be a useful tool, to be able to link to a specific tab, in other scenarios as well.
  11. Replies
    4
    Views
    480

    AX: Linking to specific tab on px page

    Situation:

    I have a page with 8 tabs, AHU1-AHU8. On another page, I have a floor plan. If I click on AHU3 from the floor plan, I want it to load up the page with the tabs, but focus on the 3rd tab...
  12. Replies
    27
    Views
    1,728

    codewriter, can you please send me this info...

    codewriter,

    can you please send me this info as well:
    volfman at gmail dot com


    thanks