    I understand that 3/4 hp can do more work in an...

    I understand that 3/4 hp can do more work in an hour than 1/2 hp can. On paper, the 3/4 should have more torque at 23 ft. lb. than the 1/2 at 15.3 ft. lb.

    Assuming you do not switch motor types,...
  2. Replies
    18
    Views
    657

    Yes I was talking PSC

    Yes I was talking PSC
  3. Replies
    18
    Views
    657

    Motor HP vs Amps

    I understand the importance of replacing motors by FLA rating. But when doing this, can you change HP as well?

    Example:

    Century D1076 - 3/4 HP, 208/230 V, 1075 RPM, 4.0 FLA
    GE 3588 - 1/2 HP, ...
  4. Replies
    14
    Views
    2,200

    It is about 20-24" inches from the left wall......

    It is about 20-24" inches from the left wall... About 12-16" from the back wall.

    When I was by there it wasn't full of lint yet, but that was only because it was brand new. The yard wasn't even...
  5. Replies
    14
    Views
    2,200

    Not my install...

    Not the best location for a HEAT PUMP and clothes dryer vent.472461
  6. Replies
    1
    Views
    233

    Clarification on a textbook example

    Hello,

    I've been reading "commercial refrigeration for Air Conditioning Technicians". There is a statement in there that has me scratching my head a little.

    It is in chapter discussing...
  7. Anyone?

    Anyone?
  8. Which TXV to stock, Sporlan R series or Danfoss TR6?

    I'm trying to decide which TXVs to keep on the van. I try to keep a Sporlan BQ kit handy, but that won't do for heat pumps.

    If the BQ series would through in the internal check, it would cover it...
  9. Replies
    14
    Views
    903

    Thanks for all the good information!

    Thanks for all the good information!
  10. Replies
    5
    Views
    466

    Thanks for the input. Currently there is no air...

    Thanks for the input. Currently there is no air positively supplied to the room.

    I didnt expect 0 sp on the exhaust but was just stating the fan capacity. The 16 inch duct is just about 4 foot...
  11. Replies
    20
    Views
    1,475

    Burners are clean. They werent the problem. Old...

    Burners are clean. They werent the problem. Old HSI was weak. The GlowFly did better and is in the gas flow. Like I said the gas valve should open slow but isnt...
  12. Replies
    14
    Views
    903

    Isn't mercaptan used in LP and natural gas? LP...

    Isn't mercaptan used in LP and natural gas? LP uses copper frequently.
  13. Replies
    14
    Views
    903

    Why aluminum tubing for pilots?

    Why is aluminum tubing used for pilots?

    It isn't to save the cost of copper. It might have been at some point.

    Then I thought maybe it was for vibration and stress cracks, but compressors and...
  14. Replies
    20
    Views
    1,475

    I talked to the homeowner. The problem is better,...

    I talked to the homeowner. The problem is better, but not completely solved.

    I've done a little more research and the Honeywell VR8205H8016 gas valve comes up as a slow opening. In watching the...
  15. Replies
    5
    Views
    466

    Anyone willing to give me their two cents on this?

    Anyone willing to give me their two cents on this?
  16. Replies
    20
    Views
    1,475

    No smart valve.

    No smart valve.
  17. Replies
    20
    Views
    1,475

    HSI glows but won't light gas

    Get a call for "furnace won't light - sometimes". I hate these. Get there and it operates flawlessly. I probably cycle it 20 times in about a half hour. No problems.

    The HSI has a small hotspot as...
  18. Replies
    5
    Views
    466

    Kitchen exhaust fan.

    I have a bakery with a kitchen exhaust fan that hasn't operated since they have been in the building. It wasn't a kitchen before they were there.

    The room is about 32x35 (8 foot dropped tile...
  19. Replies
    12
    Views
    552

    I couldnt get a picture but there were a couple...

    I couldnt get a picture but there were a couple small holes as well as about 3x more rust. I'm guessing the ac freezes up somewhat often because there looks to be water running down the inside of...
  20. Replies
    12
    Views
    552

    Failed heat exchanger

    Gotta love when it is easy to fail a heat exchanger...459951459961
  21. Replies
    18
    Views
    796

    Currently it wont produce enough heat to keep the...

    Currently it wont produce enough heat to keep the fanstat on. The blower cycles but the burner doesn't. I tried to unscrew a couple of the burners but the are froze and the brass on top was...
  22. Replies
    18
    Views
    796

    Both are 100k btu, but the replacement is made...

    Both are 100k btu, but the replacement is made for a grill or turkey fryer!



    It's getting replaced... was just joking about repair... No safety devices. The pilot is on a ball valve. Main valve...
  23. Replies
    18
    Views
    796

    Looks like a direct replacement,...

    Looks like a direct replacement, right?459361459371
  24. Replies
    18
    Views
    796

    I found no problem with the heat exchanger. The...

    I found no problem with the heat exchanger. The round burner is shot. It is a 100k btu unit putting out about 40k by clocking the meter. I tried to work on it and it is seized and brittle.

    If I...
  25. Replies
    18
    Views
    796

    Thanks for the confirmation. It's before my time....

    Thanks for the confirmation. It's before my time. I figured units in the 70s had gas valves similar to todays. This had a seperate valve, regulator, and thermocouple control. It was interesting. It...