Search:

Type: Posts; User: cynic

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    14
    Views
    2,410

    How big is the bin ?

    How big is the bin ?
  2. Replies
    16
    Views
    2,208

    Think you are right Noel.... wonder if that air...

    Think you are right Noel.... wonder if that air vent has anything to do with it filling up.
  3. Thread: Call Back-A-Rama

    by cynic
    Replies
    19
    Views
    1,251

    I love a challenge but following people around...

    I love a challenge but following people around too much does tend to get depressing. A consultant was in where I work and said callbacks and non billable hours resulting from them were the...
  4. Thread: TRASH ROOMS

    by cynic
    Replies
    4
    Views
    1,522

    Low bid ? :) the cooler the better we run them...

    Low bid ? :) the cooler the better we run them about the same temps as a regular walk in cooler, and all of them are basicly walk in coolers that happen to be full of trash or in a few cases dead...
  5. Thread: Submarine Pool

    by cynic
    Replies
    11
    Views
    811

    dunno how much more damage salt water would do...

    dunno how much more damage salt water would do but had a resturant where the basement turned into a swimming pool, replaced all the fan motors and relays made new fan shrouds and all is still running...
  6. Cam and microswitch setup like on the older...

    Cam and microswitch setup like on the older scottsman cubers. slow running motor with a disk mounted to it,then cut in as many spaced out areas as needed to get the switch to make and break when...
  7. Replies
    10
    Views
    913

    Multi circuit condensors is probably why they do...

    Multi circuit condensors is probably why they do it that way. That and have to agree with cost also 2 stats and the dual input p66 are cheaper than the 4 pressure controls plus p66 that would be...
  8. Replies
    3
    Views
    3,512

    Not sure but this might help ...

    Not sure but this might help

    http://www.alliantenergy.com/stellent/groups/public/documents/pub/bus_exp_eff_012399.hcsp
  9. Replies
    16
    Views
    3,466

    If you cant find one deep socket and a grinder...

    If you cant find one deep socket and a grinder can make one.
  10. Dunno if hot gas would be a good idea on a heat...

    Dunno if hot gas would be a good idea on a heat pump. does the unloader actually work ? I have seen more than one carrier that had something stuck under the unloader solonoid right from day one...
  11. Replies
    5
    Views
    787

    Might want to leave it alone, sometimes what...

    Might want to leave it alone, sometimes what looks bad is actually doing a better job than paint would. Whats the evaporater made of ? fish don't like copper.
  12. Replies
    38
    Views
    2,194

    Anyone care to imagine what the vast majority of...

    Anyone care to imagine what the vast majority of calls to GE tech support are ? Hotel ptacs and who looks at them first ? Then again if they wanted to pay for my time on hold..... :)
  13. Replies
    19
    Views
    2,284

    well if its leaking how do you follow the...

    well if its leaking how do you follow the instructions ??? Have already found and repaired leaks on 2 units that someone put that stuff in one did have a dead compressor due to a blocked drier and...
  14. Thread: got rear ended!

    by cynic
    Replies
    30
    Views
    1,642

    I got sideswiped by a schoolbus last winter...

    I got sideswiped by a schoolbus last winter getting paid for the time was not even an issue, same thing when a van dies even on overtime. Remind me to thank my boss for not being a total A$$ and...
  15. Replies
    15
    Views
    1,684

    Ask the brilliant engineer who placed it there :)...

    Ask the brilliant engineer who placed it there :)

    Is there enough space to put a duct on the "return" and pull air from above roofline without killing condensor airflow ? or a combination of a...
  16. Replies
    12
    Views
    5,643

    Lable the pipes, see yellow and grey mostly

    Lable the pipes, see yellow and grey mostly
  17. Replies
    25
    Views
    1,441

    No sane person would do it where I work :)

    No sane person would do it where I work :)
  18. Replies
    11
    Views
    5,494

    http://www.mrslim.com/home.asp roam around...

    http://www.mrslim.com/home.asp

    roam around and download the service info for it. old page it was eaiser to find but the info is still there.
  19. Replies
    14
    Views
    1,374

    Ran into that last summer not one unit... all 6...

    Ran into that last summer not one unit... all 6 on the roof of a strip mall ducted backwards.
  20. Replies
    11
    Views
    1,530

    Sonc... havent had the misfortune of seeing one...

    Sonc... havent had the misfortune of seeing one of those yet. have had the misfortune of changing a few of those tandem bristols though.
  21. Replies
    11
    Views
    1,530

    what kind of york has split coils ? only yorks I...

    what kind of york has split coils ? only yorks I have seen with them are the older residential ones. If its a coil like the tranes and carriers that need to be split there is no way to get them...
  22. Thread: BEACON SYSTEM

    by cynic
    Replies
    7
    Views
    1,062

    They have changed sensors/thermistors yet again...

    They have changed sensors/thermistors yet again now they are all white. They are so reliable if one is bad I just toss in the 3 or 4 other ones while in the coil.
  23. Thread: Sporlan Sold?

    by cynic
    Replies
    12
    Views
    1,403

    uh oh well it could have been worse imagine if...

    uh oh well it could have been worse imagine if emerson bouyght them :)
  24. Replies
    8
    Views
    1,174

    A regular steel bolt ? thats a good idea need...

    A regular steel bolt ? thats a good idea need to try it on the next one I do.
  25. Thread: coffin freezer

    by cynic
    Replies
    3
    Views
    1,768

    Have rewired a couple that someone thought the...

    Have rewired a couple that someone thought the fans should have been off during defrost. Terminator/overtemp limit shut off defrost before coil was cleared of ice and bottom layer of product was...
Results 1 to 25 of 152
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event