Search:

Type: Posts; User: chillerout1

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    19
    Views
    450

    if the ac has a high pressure switch for it to...

    if the ac has a high pressure switch for it to have a UL listing there can be no core under the pressure switch.
  2. Replies
    19
    Views
    450

    no cores under high pressure switches on any...

    no cores under high pressure switches on any equipment with UL listing
  3. Replies
    58
    Views
    777

    they are getting paid it is just in the form of...

    they are getting paid it is just in the form of tuition tutors custom meal plan and other perks, I venture to say that more than 50% would not be there if academic standards weren't lowered for the "...
  4. Replies
    13
    Views
    377

    w-r 1f85-0471 option 3 in the configuration menu...

    w-r 1f85-0471 option 3 in the configuration menu is what you are looking for
  5. Replies
    13
    Views
    377

    mine is set at 2 degrees I think the most I have...

    mine is set at 2 degrees I think the most I have seen that is allowed in the stat is 6 there are many out there that let you set that parameter in them its again how much you want to spend.
  6. J B industries has a you tube channel and info on...

    J B industries has a you tube channel and info on their website under marketing specific to our field you can look at regarding vacuums
  7. Replies
    13
    Views
    377

    and are you looking for a brand name or just...

    and are you looking for a brand name or just anything?
    I would do either a Honeywell or White-Rodgers(emerson)
  8. Replies
    13
    Views
    377

    just about any programmable digital will let you...

    just about any programmable digital will let you set the differential in it, question is how much are you willing to spend. no, not all the ones at home depot are the same that we get at the...
  9. Replies
    27
    Views
    698

    hopefully you took these readings at the...

    hopefully you took these readings at the compressor terminals with the wires unhooked and if so I would say yo have a bad compressor, if not go back and do it correctly with leads unhooked.
  10. Replies
    12
    Views
    328

    if youre nice you can take the model and serial...

    if youre nice you can take the model and serial number and go to your local trane office and they should be able to tell you who the original purchaser of the unit was
  11. Replies
    6
    Views
    201

    under the epa rules since you are not using it...

    under the epa rules since you are not using it for refrigeration purposes you can just release it , as an example all those cans that dust off your computer that you buy from office depot are...
  12. Replies
    6
    Views
    299

    heat should have been on in MAU maybe tripped out...

    heat should have been on in MAU maybe tripped out on safety or error. could the rtu's been doing purge/ morning warmup cycle ? you may need to check the settings on the lennox units
  13. Replies
    3
    Views
    160

    copper and heat tape with trap outside preferably...

    copper and heat tape with trap outside preferably into a drain or at least on slope away from freezer. if he does it his way he will be back until he gets it right
  14. Replies
    44
    Views
    1,246

    I'm not sayin someone shot it down although...

    I'm not sayin someone shot it down although that's possible but a military satellite somewhere tracked it and knows its last and final location but they don't want anyone to know they can track it...
  15. Replies
    44
    Views
    1,246

    somebody's military knows where it went down at...

    somebody's military knows where it went down at they just don't want to say because it would giveaway information that they don't want revealed. you cant convince me that a plane that large can fly...
  16. Replies
    8
    Views
    356

    i looked for that model but it didn't pop up but...

    i looked for that model but it didn't pop up but an al6b060 did and the install instructions call for 3/8 and 1 1/8 line size so i would go with what ever your install instructions call for
  17. the data for that transformer says 120/230...

    the data for that transformer says 120/230 primary and 12/24 secondary so are you sure you measured correctly? recheck it . just google the number you posted for the transformer to get info
  18. Replies
    10
    Views
    235

    why would you use an isolation relay?

    why would you use an isolation relay?
  19. Replies
    10
    Views
    235

    not that I know of.

    not that I know of.
  20. Replies
    10
    Views
    235

    you could just buy two of the cheap heat only...

    you could just buy two of the cheap heat only stats and put a switch in to swap between the two . set one high and one low.
  21. Replies
    3
    Views
    367

    carrier used to offer one but don't remember...

    carrier used to offer one but don't remember model number or if it is still available. 33cs400-01 is carrier part number may be more than you want for your purpose it is a commercial stat don't ever...
  22. Replies
    32
    Views
    1,561

    I've worked in plants where the employees worked...

    I've worked in plants where the employees worked schedules like that they get 40 hrs straight time and 4 ot 1 week and 36 hours the next and works out for them they still get the equivalent of 80hrs...
  23. Replies
    32
    Views
    1,561

    I guess you're not union?

    I guess you're not union?
  24. heat exchanger

    heat exchanger
  25. air proving switch for combustion blower when gas...

    air proving switch for combustion blower when gas comes on changes pressure differential in hx is a possibility
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event