  1. I've found...the newer R404 commercial temp units...

    I've found...the newer R404 commercial temp units will need a time clock while the older R12 style units running a R409 are more forgiving but that likely comes back to what 2Sac stated, bigger...
  2. Replies
    9
    Views
    424

    Sounds like you have a Manotowic but anyway, the...

    Sounds like you have a Manotowic but anyway, the water pump should continue to run some water over the cubes while the hot defrost is warming. ( I think! I know Manotowics do.)

    Do yourself a...
  3. Replies
    71
    Views
    3,483

    The hardest ones to work on are 1). the cruddy...

    The hardest ones to work on are
    1). the cruddy never cleaned looking like a grease collector,
    2). the designs requiring 4 hands to take apart & put back together.
  4. Replies
    46
    Views
    2,107

    You cut out the dryer. You blew thru the cap...

    You cut out the dryer. You blew thru the cap tube? Into the evaporator? Out of the evaporator into the compressor back thru the discharge, thru the condenser back to where you started? Really? I...
  5. Replies
    22
    Views
    1,438

    If your thumbs get tired & you are careful a...

    If your thumbs get tired & you are careful a mallet comes in handy too but certainly use heat in any form first.
  6. The quality of yellow brass is, well, not very...

    The quality of yellow brass is, well, not very good. The copper content is very low. I'd use 45% with white flux. Sil fas can be a hassle on brass. But also keep in mind, yellow brass requires less...
  7. Replies
    23
    Views
    1,298

    I use to leave the Supco's 3-1 in place too. Did...

    I use to leave the Supco's 3-1 in place too. Did it a few times. Strangely enough two compressors with Supco's shorted out with a few months. I can't say for sure if the Supco created the issue,...
  8. Replies
    17
    Views
    953

    I do it for the free food...

    I do it for the free food...
  9. Replies
    27
    Views
    1,833

    I believe GT is from Quebec speaking and writing...

    I believe GT is from Quebec speaking and writing in a language he doesn't use as often as you. He's very detailed
  10. Replies
    14
    Views
    1,109

    Partially restricted cap tube. This is the...

    Partially restricted cap tube. This is the hardest problem on any reach in to troubleshoot.

    If you adjust head pressure to match ambient or thereabouts, I'd think your suction will be down below...
  11. Replies
    6
    Views
    618

    Argon much heavier gas than nitrogen thus larger...

    Argon much heavier gas than nitrogen thus larger molecules. But that would be considered a minor difference. The cost be the biggest difference. And you would use same regulator. CGA 580 nut &...
  12. Replies
    13
    Views
    564

    Your compressor will certainly see more heated...

    Your compressor will certainly see more heated durning the initial cool down. However, did you check amp draw?
  13. Heat it with an Anthracite coal stove. No...

    Heat it with an Anthracite coal stove. No kidding! That's what I do. The balance of my house is heated too.
  14. Replies
    13
    Views
    804

    I also agree, with this cold snap, good chance...

    I also agree, with this cold snap, good chance the unit was undercharged after the last repair.
  15. I getet a text first thing this morning, no heat....

    I getet a text first thing this morning, no heat. Rheem 10 ton package unit. Newer unit, but so far two out of three inducer motors died in the past year, figured #3 dead. But find out after 30...
  16. Replies
    4
    Views
    457

    I don't think it'd be a good idea to oversize...

    I don't think it'd be a good idea to oversize your refrigeration condenser unit. I'd match the load.
  17. Replies
    8
    Views
    662

    A larger motor if able to fit should not be...

    A larger motor if able to fit should not be overheating. Although if the blade is wrong in some way....

    But I'd be confirming with my VOM that you do have 120v and not 230v. I've see unit...
  18. Yes

    Yes
  19. What is the coldest spot in any refrigeration...

    What is the coldest spot in any refrigeration unit? What temp do you figure is at the outlet of the tev on a walk in freezer likely running 404? What controls the flow of refrigerant from the...
  20. Replies
    41
    Views
    2,242

    Cap tube systems reach in units are for storing...

    Cap tube systems reach in units are for storing product already cooled or frozen. i.e close to the cook's reach but product typically stored in a walk-in until the day it is needed.
    TXV units are...
  21. Replies
    52
    Views
    3,422

    In 2012, replaced a 1hp K body dated 1983...and...

    In 2012, replaced a 1hp K body dated 1983...and it sat outside without a block heater.
  22. Replies
    12
    Views
    524

    why R401, not R409?

    why R401, not R409?
  23. Replies
    40
    Views
    2,248

    Jump out all switches in circuit and test...You...

    Jump out all switches in circuit and test...You could have a switch closing but offering high resistance creating a voltage drop.
  24. Thread: Reach in cooler

    by Capz
    Replies
    56
    Views
    2,824

    Ahh, R12 to R134 conversion? My experiences show...

    Ahh, R12 to R134 conversion? My experiences show same symptoms. Lower SH & poor efficiency. Set the txv and let it go, see what happens. Or convert to R409. You should see better results.
  25. Replies
    20
    Views
    1,263

    I agree. At first i thought I it was nearing 20...

    I agree. At first i thought I it was nearing 20 yrs old likeunit most other equipment here. I did change our plans. Picking up parts today from PP. I certainly appreciate everyone's input and...