01-09-2012, 12:26 PM
Thread: Tracer Summit Runtime Hours
by FutureRMO- Replies
- 0
- Views
- 179
Tracer Summit Runtime Hours
Does anybody know how to get the previous year's runtime hours? I am doing some tenant billing so i need runtime hours for like jan feb march april 2011 etc how would i go about doing that?
-
08-02-2011, 08:56 PM
Thread: Another Trane SWUD question
by FutureRMO- Replies
- 14
- Views
- 1,791
Thanks maxster sounds good..... time to get down...
Thanks maxster sounds good..... time to get down and dirty tomorrow i will fill you guys in
-
08-02-2011, 08:00 PM
Thread: Another Trane SWUD question
by FutureRMO- Replies
- 14
- Views
- 1,791
Very nice maxster..... our chemical treatment has...
Very nice maxster..... our chemical treatment has been iffy at times.... can i acid wash the tubes or only punch them?
-
08-02-2011, 06:56 PM
Thread: SWUD question
by FutureRMO- Replies
- 12
- Views
- 1,148
sorry for the late response.... apparently during...
sorry for the late response.... apparently during construction of this floor the demo guys cut the line to the sensor so that is why im getting the error message .... so a quick call to trane and a...
-
08-02-2011, 06:53 PM
Thread: Another Trane SWUD question
by FutureRMO- Replies
- 14
- Views
- 1,791
im a centravac guy so im very fond of Trane.......
im a centravac guy so im very fond of Trane.... but i scratch my head with these SWUD units..... i do constant maintenance on them i.e. new filters check belts strainers etc etc but on some days...
-
08-02-2011, 06:16 PM
Thread: Another Trane SWUD question
by FutureRMO- Replies
- 14
- Views
- 1,791
Rough day today as it was hot as hell..... first...
Rough day today as it was hot as hell..... first thing i did in the morning was put gauges on and my low side was reading 88 psig and high side 310.... i was surprised at these high pressures.... had...
-
08-01-2011, 08:23 PM
Thread: Another Trane SWUD question
by FutureRMO- Replies
- 14
- Views
- 1,791
Another Trane SWUD question
Hey guys, I am new to package units and lost with the Trane SWUD units. Two of my compressors are going off on overload trip. Where to begin where to begin??? Any help would be much apperciated....
-
05-24-2011, 03:56 PM
Thread: SWUD question
by FutureRMO- Replies
- 12
- Views
- 1,148
sorry guys i screwed up.... i actually changed...
sorry guys i screwed up.... i actually changed the space temp. sensor which i thought was bad.... does anyone know where exactly the supply air/ day cooling temp reset sensor is?
-
05-16-2011, 02:44 PM
Thread: SWUD question
by FutureRMO- Replies
- 12
- Views
- 1,148
I am new to package units... was working with a...
I am new to package units... was working with a trane centravac before (love those machines) .... so i set the setpoint lower to 54 degrees....today the DA went all the way down to 61 and shot back...
-
05-13-2011, 10:01 PM
Thread: SWUD question
by FutureRMO- Replies
- 12
- Views
- 1,148
checked loose connections but to no avail.......
checked loose connections but to no avail.... this unit if i set the setpoint temp to lets say 55 degrees it wont go any lower that 61 supply air and then goes from cooling level 1 to supply on.......
-
05-13-2011, 01:50 PM
Thread: SWUD question
by FutureRMO- Replies
- 12
- Views
- 1,148
SWUD question
I'm having problems with one unit where i get a message on my tracer system that states "Temp. Reset Sensor Fail"- but i changed the temp sensor already.... any ideas?