Search:

Type: Posts; User: smadave

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Central/Southern NJ - looking for residential installers and service technicians

    We are currently looking for at least one qualified service technician and at least three installers

    Service Tech - Must have at least (5) years experience in residential service. Must be...
  2. Looking for blower performance data for a ducane furnace CMPB075U3

    Im trying to find blower performance data for a Ducane furnace model # CMPB075U3 if anyone can help me out, I would greatly appreciate it.

    Dave
  3. Our Benefit package includes: Blue cross blue...

    Our Benefit package includes:

    Blue cross blue shield medical
    Dental
    Vision
    Life Insurance
    Short-term disability
    Long-term disability
    6 paid holidays/yr
    Paid Vacation
  4. Looking for a Service Tech, Lead Installer, and a Helper for Ocean/Monmouth County NJ

    Well Established Energy Conservation company just opened an office in East Freehold, NJ for work in Monmouth and Ocean counties. We are currently in need of:

    (1) Service Tech - looking for someone...
  5. Do any of these digital guages give you a vaccuum...

    Do any of these digital guages give you a vaccuum reading?

    Thanks,

    Dave in NJ
  6. Replies
    13
    Views
    852

    I'm a HVAC contractor in NJ and I am familiar...

    I'm a HVAC contractor in NJ and I am familiar with the utilities, but most familiar with NJR. They do have their own in house (union) installers. They tend to be more expensive than most but they do...
  7. Replies
    21
    Views
    3,726

    Im from NJ also and like you said there is alot...

    Im from NJ also and like you said there is alot of talk about guys getting knocked down for using R-6...hasnt happened to me yet knock on wood. Of course the people telling me this happen to work at...
  8. Replies
    9
    Views
    15,431

    If you go with a standard atmospheric type boiler...

    If you go with a standard atmospheric type boiler you will have to purchase and install a power vent kit. I do not recommend these kits because they are very loud, expensive, they have to be...
  9. Replies
    5
    Views
    752

    LOL - Thats pretty good but not what im referring...

    LOL - Thats pretty good but not what im referring too!!

    Thanks anyway...
  10. Replies
    5
    Views
    752

    Ductless Split Question??

    Hello and Happy New Year to All!! I am looking for a ductless that offers the ability to install (1) additional supply outlet to a small adjoining room. I know that Carrier used to have a convertible...
  11. Replies
    6
    Views
    1,545

    Hello, It is still available. I can send you...

    Hello,

    It is still available. I can send you pics if your interested, just send me an email address.

    Thanks,

    Dave
  12. Replies
    6
    Views
    3,202

    T The following is a reply I submitted to a...

    T
    The following is a reply I submitted to a similar post a while back. I hope that it puts things in perspective for you. Good luck...

    Dave in NJ





    Wow..where to begin. Well lets start...
  13. Replies
    6
    Views
    1,545

    Jimmbo68, I didnt sell yet I am waiting for...

    Jimmbo68,

    I didnt sell yet I am waiting for someone to get back to me....
    I can send you pics if your interested let me know.

    Dave
  14. Replies
    6
    Views
    1,545

    Hello, You can email me at smadave@yahoo.com ...

    Hello,

    You can email me at smadave@yahoo.com

    Thanks,

    Dave
  15. Replies
    7
    Views
    2,188

    Darbyd Sorry but im not taking credit...

    Darbyd

    Sorry but im not taking credit cards...cash & carry only. I have no problem with you picking the unit up. I would even be willing to drive west a bit if it helps you. Email me at...
  16. Replies
    7
    Views
    2,188

    It has a 24 X 24 Hood Thanks, Dave

    It has a 24 X 24 Hood

    Thanks,

    Dave
  17. Replies
    0
    Views
    1,150

    Brand New RUUD 10 SEER Condensers

    For Sale:

    RUUD 10 SEER 2 ton condenser UAKB018JAZ

    RUUD 10 SEER 1.5 ton condenser UAKB024JAZ

    I am located in NJ for anyone interested.
    I am not going to ship these units so they must be...
  18. Replies
    6
    Views
    1,545

    Rigid Threading Setup - NEW - Never Used!

    For Sale: Threading Setup Brand New! Never Used! Includes:

    Rigid Model 600 Power Drive with 1/2", 3/4", 1", 1 1/4" Dies (Paid $1,115.00)

    Rigid Tri-Stand Chain Vise (Paid $422.00)

    Rigid...
  19. Replies
    7
    Views
    2,188

    Alnor - Balometer Jr. - NEW - Never Used!!

    For Sale: Alnor Balometer Jr.

    Brand New - Never Used!!

    Paid $1,375.00

    Selling for $950.00 Firm!! (does not include shipping)
  20. Replies
    1
    Views
    905

    Fyrite Pro 120 - NEW never used!!

    For Sale: Fyrite Pro 120 Combustion Analyzer with wireless thermal printer!!
    NEW - Never Used!!

    Paid $1,100.00

    Selling for $800.00 Firm (does not include shipping)
  21. Replies
    0
    Views
    1,054

    Bacharach Kit - NEW never used!!

    For Sale: Bacharach Oil Combustion Test Kit. New Never Used!

    Paid $600.00

    Selling for $400.00 Firm (does not include shipping)
  22. Replies
    6
    Views
    777

    I live on the Jersey shore and 95% of my installs...

    I live on the Jersey shore and 95% of my installs are in flood zones. The codes make us secure the condenser to the platform in case we get the "100 year flood" the condenser would try to float away....
  23. Replies
    12
    Views
    2,534

    I guess I should bring closure to this thread so...

    I guess I should bring closure to this thread so that other techs who may come across this problem will know what to do. After getting in touch with tech support I was told that the problem is due to...
  24. Replies
    7
    Views
    591

    I got your email...I emailed you back. Let me...

    I got your email...I emailed you back. Let me know if you didnt get it.

    Thanks,

    Dave in NJ
  25. Replies
    7
    Views
    591

    Rabram, I can take a look at it for her, its...

    Rabram,

    I can take a look at it for her, its alittle north of me, but we go there from time to time. Email me at smadave@yahoo.com and give me the particulars.

    Thanks,

    Dave in NJ
  26. Replies
    12
    Views
    2,534

    I appreciate your candid response. I do not...

    I appreciate your candid response. I do not believe the LED blinking is an error code simply because there is no sequence. In other words, it does not blink three times, pause blink two times, it...
  27. Replies
    12
    Views
    2,534

    To answer your question, yes both are insulated...

    To answer your question, yes both are insulated and seperated. I agree the pressures are low, maybe due to the fact I only weighed in 2.1 lbs. Perhaps it wasnt enough, but I was looking for...
  28. Replies
    12
    Views
    2,534

    Need help with Sanyo Ductless-Split!

    Hello everyone,

    I am having trouble with a new Sanyo ductless split I installed. I usually do not use Sanyo (I prefer Fujitsu for a number of different reasons) but the application called for...
  29. Thread: Summit Coils

    by smadave
    Replies
    8
    Views
    1,576

    I called summit today...they dont know either! Go...

    I called summit today...they dont know either! Go Figure...


    Dave in NJ
  30. Thread: Summit Coils

    by smadave
    Replies
    8
    Views
    1,576

    I dont want to make the mistake of guessing its a...

    I dont want to make the mistake of guessing its a 5 ton coil just because it has a 58 in the model number. Its matched up to an Air Pro condenser, and the model number is too faded to read. I took...
  31. Thread: Summit Coils

    by smadave
    Replies
    8
    Views
    1,576

    Summit Coils

    Hello everyone. Need some help with a model number on a Summit Coil. The model # is CA2N58-MF the coil is approx. 10 yrs. old. Does anyone know what size coil this is? Also, is there a TXV in this...
  32. Replies
    0
    Views
    484

    Mini Split Install - Sanyo High Wall

    We are installing a Sanyo High Wall and the everything is coming in the left-rear. It seems we are having a tough time getting everything to fit nicely enough where the unit wants to relax and sit...
  33. Replies
    44
    Views
    5,635

    When I do an install using this application, I...

    When I do an install using this application, I always use a (support box) which is just a short plenumn that the coil sits on. That gives you enough height to run your drains properly. You can get...
  34. Replies
    3
    Views
    1,064

    Thanks... Dave in NJ

    Thanks...


    Dave in NJ
  35. Replies
    3
    Views
    1,064

    Carrier 48TME Warranty?

    Does anyone know what the Warranty is for the 48TME Series RTU.

    Thanks,

    Dave in NJ
  36. Replies
    4
    Views
    914

    First one took longer (one day) after the...

    First one took longer (one day) after the learning curve you can do one in a 1/2day easily. Hope this helps...

    Dave in NJ
  37. I can help you...email me with particulars. ...

    I can help you...email me with particulars.

    Thanks,

    Dave
  38. Replies
    17
    Views
    1,532

    Take a look at the Monitor BS tanks. Very nice...

    Take a look at the Monitor BS tanks. Very nice tank, good design. Check it out at www.monitorproducts.com

    Dave in NJ
  39. Replies
    14
    Views
    1,316

    Of course the installer/installation is key,...

    Of course the installer/installation is key, (having said that) My preference is the Carrier Infinity HP paired with an FE4 fan coil and the "smart" electric back up heat. Very nice system....

    ...
  40. Replies
    6
    Views
    760

    If were talking after market stuff, then I like...

    If were talking after market stuff, then I like EWC. Very nice product, great support if needed, well priced. The best zoning equipment overall in my opinion is the Carrier Infinity Zoning products....
  41. Replies
    6
    Views
    842

    Those dang Carrier models...they are...

    Those dang Carrier models...they are noisy:rolleyes:

    Dave in NJ


    (Psst..hey dude maybe its the ductwork (design) and not the furnace that causing the problem)
  42. Thread: mini split

    by smadave
    Replies
    5
    Views
    751

    From my experience the ductless splits are much...

    From my experience the ductless splits are much more forgiving when it comes to long linesets. Should not be a problem. I dont know what brand you plan to use but I like the Fujitsu units. Very nice...
  43. Replies
    13
    Views
    5,070

    I agree ;)

    I agree ;)
  44. Replies
    4
    Views
    650

    First - those prices are low Second - there...

    First - those prices are low

    Second - there are other boilers out there that do what your looking for.
    NIT and Monitor just to name two.

    Third - your best option is just to...
  45. Replies
    32
    Views
    3,156

    I think your entitiled to your opinion but if...

    I think your entitiled to your opinion but if your going to come on here and flat out call equipment junk, you better be able to elaborate or else you will not last long here.

    The comsumer reports...
  46. Replies
    13
    Views
    5,070

    I always hated those Bristol compressors in the...

    I always hated those Bristol compressors in the goodmans. Changed alot of them. Put in a Copeland and forget about it.

    Dave in NJ
  47. Replies
    10
    Views
    1,124

    Its a good idea and this is where future building...

    Its a good idea and this is where future building practices are going anyway. I am reading about conditioning attics, basements, crawl spaces. Much more energy efficient.

    Dave in NJ
  48. Replies
    108
    Views
    11,464

    THats Pathetic! Dave in NJ

    THats Pathetic!


    Dave in NJ
  49. Replies
    3
    Views
    647

    If I am understanding you correctly, you are...

    If I am understanding you correctly, you are finishing the basement and you want to heat and cool it. Now you have that extra load to consider which I think the previous poster is missing. First, you...
  50. Replies
    10
    Views
    981

    Dash Maybe I could have said it better. I...

    Dash

    Maybe I could have said it better. I really like the Infinity system, however, it is very sensitive and not very forgiving. IMHO some of the Data should be made available to the home owner,...
Results 1 to 50 of 431
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event