Search:

Type: Posts; User: merlin73

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Job Opening central New Jersey ( Ocean& Monmouth county )

    Looking for a Residential and light Commercial Qualified Technician/Installer that has at least 2 years Experience, Own tools, able to work late, weekends, and being on call.
    Contact E&L heating...
  2. Thread: Hello.

    by merlin73
    Replies
    2
    Views
    199

    Hello

    Hello
  3. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    its been good since we changed the board, Knock...

    its been good since we changed the board, Knock on wood!
  4. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    i love it when the engineer never heard of that...

    i love it when the engineer never heard of that problem.. he/she can come to my job site or yours to have first hand at it!!:eek2:
  5. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    according to our last tech, he replaced the gas...

    according to our last tech, he replaced the gas valve thinking it was getting stuck, Then another tech went there check flame rod which was good and replaced it with one from another unit up there....
  6. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    ok, thanks.. Flame sensor was clean and had a...

    ok, thanks..
    Flame sensor was clean and had a 3.7 microamp reading. control board had a little rust on the front side by the resistors but pretty clean.
  7. I would call a service tech to get you some heat.

    I would call a service tech to get you some heat.
  8. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    techs had 3.47 at manifold and 7.58 at main. I...

    techs had 3.47 at manifold and 7.58 at main.
    I just need to know if others came across this issue and what they found. I never came across this error code.
  9. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    techs had 3.47 at manifold and 7.58 at main. I...

    techs had 3.47 at manifold and 7.58 at main.
    I just need to know if others came across this issue and what they found. I never came across this error code.
  10. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    ok Tech just emailed me all info exact model :...

    ok Tech just emailed me all info
    exact model : YSC048A1EHA1H000000000000
    SERIAL : 504101023L
  11. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    I'LL get the info from my Tech,

    I'LL get the info from my Tech,
  12. Thread: YSC036E issue

    by merlin73
    Replies
    28
    Views
    2,182

    YSC036E issue

    Hello all,
    I have a YSC036E trane roof top unit that another tech went out on and said he had 5 Flashes on the control "flame with out gas"
    He went and changed the gas valve for some reason. ? I...
  13. Thread: Rheem

    by merlin73
    Replies
    3
    Views
    566

    Rundawg, thank you for the manuals. I will see if...

    Rundawg, thank you for the manuals. I will see if it show what I am looking for.
  14. Thread: Rheem

    by merlin73
    Replies
    3
    Views
    566

    I need to see a completed pic of this. ...

    I need to see a completed pic of this.
    http://i277.photobucket.com/albums/kk43/hideoustown/rustedoutRheemRRGG1.jpg
  15. Thread: Rheem

    by merlin73
    Replies
    3
    Views
    566

    Rheem

    Hello all,

    I just changed a heat exchanger on a Rheem RTU Model RRGG-10E43JKR.
    I have a question about the panels where it exhausts,
    you have the plate to separate the fan and exhaust with an...
  16. Replies
    13
    Views
    2,026

    I use either a control screw driver or a pick....

    I use either a control screw driver or a pick. even a paper clip works..

    Have fun the first time i did it, It sucked but after one it is easy..:cheers:
  17. Thread: new code

    by merlin73
    Replies
    8
    Views
    1,164

    Many local towns in Central Jersey by me has...

    Many local towns in Central Jersey by me has failed for not having the locking caps.
    We put them on everything that is installed now. Not worth the trip back to install caps for a failed...
  18. Replies
    21
    Views
    1,581

    I have a KTM 400 that i did a few mods too, Not...

    I have a KTM 400 that i did a few mods too, Not crazy but nice to have, I am changing the sprokets and chain this weekend, I hope I have some time to go riding in the trails this weekend or next week.
  19. Replies
    43
    Views
    4,370

    Sorry i am using the Yellow Jacket Bullet vacuum...

    Sorry i am using the Yellow Jacket Bullet vacuum pump with it.
  20. Replies
    43
    Views
    4,370

    Thanks I will try it and get back to you, I know...

    Thanks I will try it and get back to you, I know with out the micron gauge, I pressurized the system to 200 psi and let it sit for 2 hours whille doing other things and came back and was still on 200...
  21. Replies
    43
    Views
    4,370

    Joeyd, question I bought a Testo 557 with hoses...

    Joeyd, question I bought a Testo 557 with hoses and the BluVac Digital Micron Gauge last year in September and it was sitting all winter in my basement then I pulled it out for this season to use...
  22. Replies
    12
    Views
    1,379

    why not use the honeywell 8000 and hide them with...

    why not use the honeywell 8000 and hide them with the indoor sensor behind doors.
    Just a thought
  23. Replies
    40
    Views
    4,827

    between the two I would go sman3, also lookat the...

    between the two I would go sman3, also lookat the testo 557
  24. Replies
    18
    Views
    1,342

    Thanks That would be cool to see.

    Thanks That would be cool to see.
  25. Thanks for your help guys,

    Thanks for your help guys,
  26. Replies
    16
    Views
    1,154

    just to add my 2 cents, some contractors add 20%...

    just to add my 2 cents, some contractors add 20% to the heat load calc to ensure proper heating, so the guy telling you the 60 is just under may or may not be correct but he may be adding that 20% to...
  27. Thats was my original idea, but was not sure if...

    Thats was my original idea, but was not sure if it would work. So I am going to leave the piston housing with out the orfice and add a txv before the housing.

    thanks,
  28. i did state he should replace the coil but being...

    i did state he should replace the coil but being there is no leaks he rather not. It will make my life harder but he dont have the money to replace the coil. he got the condenser for nothing from a...
  29. Replies
    20
    Views
    1,654

    on the breaker is it in the electric panel or on...

    on the breaker is it in the electric panel or on the heaters, it could just be what the manufacture requires. you can get the same tonnage condenser and have a different amp draw all depends on what...
  30. Replies
    20
    Views
    1,654

    air flow sound like the issue, or maybe a bad...

    air flow sound like the issue, or maybe a bad heat strip coil. lack of info to tell.
  31. Replies
    11
    Views
    907

    LMFAO I should try it, Just to get a good laugh...

    LMFAO I should try it, Just to get a good laugh for myself.. :cheers:
  32. need advise on a expansion valve- yes or no

    Hello,

    I have a friend that has a old luxaire up flow coil model # M2UF052sa with an orfice # 87 PART NUMBER 06386997b007.
    He obtained a condenser model number TCGD48S21S1A that states it...
  33. Replies
    23
    Views
    3,248

    In new jersey some township requires a trap on a...

    In new jersey some township requires a trap on a upflow. I tried to talk to the inspector and got no where and said no problem, give me 5 min. I failed my inspection cause of it, so now everthing get...
  34. Replies
    18
    Views
    1,342

    the scale to me sound about right. this is going...

    the scale to me sound about right. this is going off what I normally get. I use my pressure to let me know if my coil is dirty
  35. Thread: Need Help

    by merlin73
    Replies
    6
    Views
    643

    why not make a small mechanical room in the attic...

    why not make a small mechanical room in the attic and insulate it and enclose all the duct work too. It will be code soon up in Jersey. maybe by 2015
    this is just a tought.
    alot of contractor make...
  36. Replies
    31
    Views
    2,208

    +1 also you should look at the manufacture specs...

    +1 also you should look at the manufacture specs to see what they would like to see. also I would need more info
  37. Replies
    40
    Views
    7,441

    go to trutechtools.com they are greta and should...

    go to trutechtools.com they are greta and should be able to assist you.

    I would also go with the testo 557 i bought them last year and really like them, I had a chance to play with the field...
  38. Replies
    11
    Views
    907

    great tool, but you hit the nail on the head. I...

    great tool, but you hit the nail on the head. I have been thinking about the ports being on the bottom for the last two years. you could always attach it to the top of the burner compartment. Sell...
  39. Replies
    3
    Views
    2,253

    nice, Now thats was funny

    nice, Now thats was funny
  40. Thread: Metal folder.

    by merlin73
    Replies
    10
    Views
    924

    I carry a 18 and 24. no reson, just what i bought...

    I carry a 18 and 24. no reson, just what i bought at the time but 18 normally gets used
  41. Replies
    68
    Views
    5,795

    I like my Testo set. No problems here. Never had...

    I like my Testo set. No problems here. Never had the Digi cool,
  42. Replies
    16
    Views
    1,543

    I like the mikita myself, and you will get it...

    I like the mikita myself, and you will get it cheaper at a home depot and lowes then the suppliers.. I went to buy a 6" hole saw at a supplier and they told me it's about $100, i said no way, I went...
  43. Replies
    56
    Views
    4,411

    only stock honeywell 4000, 6000 and 8000. can do...

    only stock honeywell 4000, 6000 and 8000. can do most anything.. with indoor and outdoor stats. Sensors good for Comm. always a good sell for controlling bosses..
  44. Replies
    74
    Views
    6,739

    +1 start there and let us know whats going on and...

    +1 start there and let us know whats going on and more info, Dont be a part changer, get some readings..
  45. Replies
    14
    Views
    4,076

    I have seen patches and wrote it up on the...

    I have seen patches and wrote it up on the invoices, recommened replacement of unit or HX, Some of the patches were done by maintenance guys..
  46. Replies
    29
    Views
    5,189

    +1 and clean the orfice. :cheers:

    +1 and clean the orfice.
    :cheers:
  47. Replies
    43
    Views
    4,370

    :cheers: I also bought my bluevac from trutech...

    :cheers: I also bought my bluevac from trutech and am enjoying it. I will be buying another one as a spare in the spring.
    I am a happy person,
    Most of my tools are from trutech, Great guys and...
  48. Thread: 409-a

    by merlin73
    Replies
    26
    Views
    2,076

    Yes I was, I am learning the refrigeration side....

    Yes I was, I am learning the refrigeration side. I am mostly heating a a/c guy. suction line right out of the evap and liquid line were wire tied together from the evap coil to the condenser above...
  49. Thread: 409-a

    by merlin73
    Replies
    26
    Views
    2,076

    Breaker was off and we turned it on, I let it run...

    Breaker was off and we turned it on, I let it run for an hour or two while working on the other two units
  50. Thread: 409-a

    by merlin73
    Replies
    26
    Views
    2,076

    I did not see one. attached to the unit

    I did not see one. attached to the unit
Results 1 to 50 of 392