Search:

Type: Posts; User: absrbrtek

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    90
    Views
    7,503

    Do I get a courtesy reach around? LMAO :) Ya I...

    Do I get a courtesy reach around? LMAO :) Ya I got tired of hearing how bad the union is, so I put a different spin on the post 5 years ago. I figured it was time to drudge it up from the dead!!
  2. Replies
    90
    Views
    7,503

    Still Sucks to be Union 5 Years Later!!!

    Pay is now $49 an hour. $100 per vested year retirement and $6.50 in the annuity. God it sucks to be union!!!! I really feel guilty about 37 years in the field and never being out of work and...
  3. Replies
    3
    Views
    1,246

    http://www.mcscontrols.com/Compressors/compressors...

    http://www.mcscontrols.com/Compressors/compressors.htm
  4. Replies
    38
    Views
    3,378

    You can thank IR for all that fun stuff. First...

    You can thank IR for all that fun stuff. First thing they did when they aquired Hussmann was cut out quality control. We got stuff in with no fan decks, wrong txv's, no wiring, etc. Still had the...
  5. Replies
    10
    Views
    1,222

    Why? If there no pressure drop across the...

    Why? If there no pressure drop across the suction drier why bother. It is not hurting anything sitting there. JMHO
  6. Replies
    14
    Views
    1,641

    The technical term is called carbon...

    The technical term is called carbon tracking/arcing. I think off the top of my head its 1 megohm per 1000 volts is the minimum needed. Ive had 460 volt compressors that were flooded with water run on...
  7. Replies
    5
    Views
    688

    Ive bid plenty of them. Make sure you have a pre...

    Ive bid plenty of them. Make sure you have a pre existing condition clause in the contract. Everything you see that is suspect gets written up and changed at the customers expense. Try to exclude...
  8. Replies
    1
    Views
    542

    Look thru here....

    Look thru here. http://www.mcmaster.com/#ball-joints/=9lbn4w
  9. Replies
    84
    Views
    28,221

    I still think of the good times we had together...

    I still think of the good times we had together almost daily. Still pretty bumbed about it.
  10. Replies
    12
    Views
    1,815

    Is it missing the restrictor in the line?

    Is it missing the restrictor in the line?
  11. Replies
    12
    Views
    1,234

    Did you split the coil?

    Did you split the coil?
  12. Replies
    7
    Views
    1,338

    They are members of the Chillergroup....

    They are members of the Chillergroup. http://www.waldinger.com/ They seem to be a good company from what I can tell.
  13. Replies
    141
    Views
    18,467

    UA Local 420 Philadelphia

    UA Local 420 Philadelphia
  14. Replies
    11
    Views
    2,080

    They jacked me around on the ph with a molybdate...

    They jacked me around on the ph with a molybdate inhibited machine. Went on for a month, add this, add that. Total bs, never again. Rocky Research is the only one Ill use. Thompson labs was good in...
  15. Replies
    11
    Views
    2,080

    Analysts Inc?

    Analysts Inc?
  16. Replies
    4
    Views
    837

    Pilot positioner....

    Pilot positioner. http://cgproducts.johnsoncontrols.com//CAT_PDF/1921035.PDF Yours is Landis and Gyr which is now Siemans.
  17. Thread: Sporlan HGB

    by absrbrtek
    Replies
    4
    Views
    754

    It works like any hgbp valve. Turn the allen...

    It works like any hgbp valve. Turn the allen screw in or out to set you pressure. Its just a remote setpoint bulb in which the bulb needs to be mounted in a stable temp. Bulb location does not...
  18. Thread: COPELAMETIC

    by absrbrtek
    Replies
    2
    Views
    685

    See page 8....

    See page 8. http://www.carlylecompressor.com/Files/Carlyle_Compressor/Local/US-en/oem_bulletins/118.pdf
  19. Replies
    6
    Views
    1,274

    They are usually the phone extenstions of the...

    They are usually the phone extenstions of the person that designed the board, equipment or function. I found that to be an interesting tidbit. The 1380 is a "Y" for York.
  20. Replies
    19
    Views
    1,747

    Dont by IR it is trash. I just pulled out a 15 hp...

    Dont by IR it is trash. I just pulled out a 15 hp IR screw that was well maintained and less then 3 years old. Also a 5 hp. Real junk IMO. Oil leaks you could never find, etc. We put in Gardner...
  21. Replies
    5
    Views
    738

    I tyhink you'll find you get more capacity out of...

    I tyhink you'll find you get more capacity out of the coil with cw over dx. Its going to be a matter of how it is reheadered and flows. I went over this years ago with a coil manufacturer. JMHO
  22. Replies
    12
    Views
    1,990

    http://www.ptsco.com/fan_shafting.html

    http://www.ptsco.com/fan_shafting.html
  23. Replies
    5
    Views
    977

    Good company. Im currently doing an overhaul for...

    Good company. Im currently doing an overhaul for them in DE. Ive known them personaly for about 12 years.
  24. Replies
    7
    Views
    4,145

    In a nutshell, the compressor is moving less...

    In a nutshell, the compressor is moving less volume of gas as it unloads. Be it by frequency, guide vanes, slide valve or rendering a few cylinders out of action. JMHO
  25. Replies
    25
    Views
    2,413

    They are not a company you would want to work...

    They are not a company you would want to work for. One of those revolving door types.
  26. Replies
    10
    Views
    1,583

    I have a Tuthill off an old HT and a carbonater...

    I have a Tuthill off an old HT and a carbonater pump from Graingers I use.
  27. Replies
    4
    Views
    969

    http://www.bacharach-inc.com/hgm300-rdm800.htm...

    http://www.bacharach-inc.com/hgm300-rdm800.htm Best on themarket IMO
  28. Replies
    10
    Views
    1,583

    A positive displacement gear pump will pull it...

    A positive displacement gear pump will pull it out.
  29. Replies
    3
    Views
    919

    My buddy owns it. He cool to party with, dont...

    My buddy owns it. He cool to party with, dont know how he is to work for. :)
  30. Replies
    161
    Views
    9,744

    16, been at it 35 yrs.

    16, been at it 35 yrs.
  31. Replies
    8
    Views
    1,468

    Buy a bacnet interface card. I dont see the FLN...

    Buy a bacnet interface card. I dont see the FLN protocol listed which is what Seimans normally uses.

    http://www.cerusind.com/catalog/documents/Manuals/PSeries_BACnet_Manual.pdf
  32. Replies
    14
    Views
    2,889

    Plugged coils will make it vibrate. Seen it all...

    Plugged coils will make it vibrate. Seen it all to many times on unit ventilaters. If its a dual coil unit, you have to split the coils. And if you think cleaning the blower wheels sucked, wait till...
  33. Replies
    2
    Views
    644

    Been there many times, great classes for a great...

    Been there many times, great classes for a great price. JMHO
  34. Replies
    18
    Views
    2,577

    Its a corner grounded delta. Easily put, one leg...

    Its a corner grounded delta. Easily put, one leg and ground are the same. That is the leg you get 0v on. http://ecatalog.squared.com/pubs/Electrical%20Distribution/Switchboards/QED-S/2700DB0202.pdf
  35. Replies
    23
    Views
    2,105

    Its not IR is it?

    Its not IR is it?
  36. Replies
    23
    Views
    2,105

    Sometimes new blood is better than dead wood. JMHO

    Sometimes new blood is better than dead wood. JMHO
  37. Replies
    23
    Views
    2,105

    Well?

    Well?
  38. Replies
    23
    Views
    2,105

    The 10K cut you'll never make up. Ive talked...

    The 10K cut you'll never make up. Ive talked myself into that I'm making less but the potential and benefits are better, it never pans out. You'll be dealing with alot of clueless people in the...
  39. Replies
    17
    Views
    3,801

    Ive had good success ramping all the fans at the...

    Ive had good success ramping all the fans at the same speed. Keeps with .3F leaving tower water.
  40. Replies
    39
    Views
    3,984

    We have a few large tunnels they heat flooring...

    We have a few large tunnels they heat flooring material in to cure it. They use in floor heating with radiators along the wall, off of a hot water boiler. They are keeping 110F in there, it could...
  41. Replies
    39
    Views
    3,984

    We have a few large tunnels they heat flooring...

    We have a few large tunnels they heat flooring material in to cure it. They use in floor heating with radiators along the wall, off of a hot water boiler. They are keeping 110F in there, it could...
  42. Replies
    7
    Views
    1,352

    Its probably an Amarillo gear box. 18 Hz is what...

    Its probably an Amarillo gear box. 18 Hz is what we run as a minimum.
  43. Replies
    13
    Views
    1,214

    I think youll be changing it again if it is burnt...

    I think youll be changing it again if it is burnt and you listen to them.
  44. Replies
    4
    Views
    713

    Is it making oil pressure and then losing it?

    Is it making oil pressure and then losing it?
  45. Replies
    16
    Views
    1,565

    LOL, dont make fun of him HMD. Hes not going to...

    LOL, dont make fun of him HMD. Hes not going to like your answer. It seems to be counterintuitive. LMAO

    And DONT, tell him about the valve repairing magic wand. Hes not a worthy subject!!!
  46. Replies
    16
    Views
    1,565

    ??????????

    ??????????
  47. Replies
    16
    Views
    1,565

    LOL, I thought of that after I posted it. I just...

    LOL, I thought of that after I posted it. I just couldnt figure out why he slammed me. I answered, he flames me, Im like WTF.
  48. Replies
    16
    Views
    1,565

    Im missing your point here if this is directed...

    Im missing your point here if this is directed towards me!!!! That is what I would do, crank on it, and pins are usually what breaks.

    PS: This is my sig line "Your poor planning does not...
  49. Replies
    16
    Views
    1,565

    Crank on it hard. It normally snaps the roll pin...

    Crank on it hard. It normally snaps the roll pin on the handle or the gears. I repair plenty of them each year that have broken off either trying to open or close it. JMHO
  50. Replies
    5
    Views
    810

    http://www.dectron.com/html_en/index.asp

    http://www.dectron.com/html_en/index.asp
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4