    I have a SCC102g that the burner compartment on...

    I have a SCC102g that the burner compartment on the steam generator is full of water. I guess there must be a crack letting water in.
    Anybody else ever seen this. Was giving a replace ignition box...
  2. Replies
    12
    Views
    1,136

    I did the battery reset and everything came up...

    I did the battery reset and everything came up working fine. Then I updated the software. After it started working and filled up I noticed the boiler access panel leaking water and replaced the seal....
  3. Replies
    12
    Views
    1,136

    top line says (Cleanjet rinse without tabs)...

    top line says (Cleanjet rinse without tabs)
    Next line says (Interrupt CleanJet?) with blue line around screen
    The rest are blank
    screen will not do anything no matter what you push
  4. Replies
    12
    Views
    1,136

    Thanks I will try that. I killed the breaker but...

    Thanks I will try that.
    I killed the breaker but did not think of the battery
  5. Replies
    12
    Views
    1,136

    Rational SCC102G

    I have a combi oven that when you turn it on it steady buzzes and displays.
    (Interrupt CleanJet?)
    It wont let you push anything or exit this screen. They said before that it showed the low water...
  6. Replies
    9
    Views
    1,179

    all of the 410a systems i have seen are expansion...

    all of the 410a systems i have seen are expansion valve not orfice.
    wouldn't the compressor need to be changed to because of the pressure change. what about the oil is it compatible with r22....
  7. Thread: Evap Size

    by cybarr
    Replies
    2
    Views
    726

    Just guessing but lets say this cooler is 8'...

    Just guessing but lets say this cooler is
    8' wide, 22' long, 7 1/2' high
    has (2) Hussmann HS-36-135A 3fan evaps.
    What size cond unit would it need.
    medium temp walk in cooler
  8. Thread: Evap Size

    by cybarr
    Replies
    2
    Views
    726

    Does anyone know what size a Hussmann Hs-36-135A...

    Does anyone know what size a Hussmann Hs-36-135A evaporator would be.
  9. Replies
    11
    Views
    1,166

    I check the Tstat.. Calling for cooling, i got to...

    I check the Tstat.. Calling for cooling, i got to the cond. unit, its indeed calling. the air discharge is cooler then ambient. check my pressures.. 150 discharge and the suction is maxed out. (so i...
  10. Replies
    20
    Views
    2,008

    Hot gas valve

    If the hot gas valve was stuck open wouldn't the cold plate be warm. The plates temp doesn't change rather the system is on or off.
  11. Replies
    20
    Views
    2,008

    f i am reading this correctly, you are saying that the piping is room temp going int

    The line coming out of the ice machine is very hot but when it gets to the condenser it is outside temp going into the condenser and the same temp coming out of the condenser.
  12. Replies
    20
    Views
    2,008

    See alot of different ideas here. Anyone know...

    See alot of different ideas here.
    Anyone know were I should start looking or what I should look for. I can't keep going back and not fixing the problem.

    Thanks for all the help I am getting.
  13. Replies
    20
    Views
    2,008

    Was the water pump running during this? That's one indication of whether it's in free

    Water pump was running and system in freeze cycle.

    Turn system off and high side drops alittle but suction stays about the same. If the high side wasn't rising and the hot gas off the compressor...
  14. Replies
    20
    Views
    2,008

    Line Temps

    Just feeling the lines by hand Hot gas off compressor (very hot), Discharge leaving ice machine to condenser very hot, by the time it reachs condenser it is outside temp. All the other lines even...
  15. Replies
    20
    Views
    2,008

    Manitowoc model SD0592N remote condenser R404a...

    Manitowoc model SD0592N
    remote condenser R404a
    Got called for no ice checked machine found suction pressure 140 and high pressure 250 , no cooling to plate
    can not figure out what is causing the...
  16. Replies
    12
    Views
    1,816

    I have a question about a Manitowoc ice machine...

    I have a question about a Manitowoc ice machine Model BD1002A

    The control board looks fairly new but is the old style with 2 red lights and terminals 1c,1d for the probe.
    Which should be a 2 wire...
  17. Replies
    12
    Views
    1,816

    Wiring diagram shows two wires for ice thickness...

    Wiring diagram shows two wires for ice thickness probe.
    but the probe on it only has one wire from it.
    could this be the wrong probe for this machine.
  18. Replies
    2
    Views
    581

    Working on an ice machine that someone recently...

    Working on an ice machine that someone recently changed the water curtain on and has fairly new bridge sensor and control board. Found bad dump valve, had rubber band inside blocking it open and...
  19. Replies
    12
    Views
    1,816

    harvest light blinks eraticly on and off when not in harvest

    Found answer

    The light will flicker as water splashes on sensor.

    any help on why it is meltng the ice.
  20. Replies
    12
    Views
    1,816

    Working on an ice machine that someone recently...

    Working on an ice machine that someone recently changed the water curtain on and has fairly new bridge sensor and control board. Found bad dump valve, had rubber band inside blocking it open and...
  21. Thread: Promax RG5000

    by cybarr
    Replies
    4
    Views
    7,327

    Does anyone know if a Promax5000 recovery unit is...

    Does anyone know if a Promax5000 recovery unit is compable of recovering R410a or do I need to purchase a new
    Promax5410a unit.
  22. Sounds like the heat anticipator in the t-stat

    Sounds like the heat anticipator in the t-stat
  23. Replies
    1
    Views
    797

    Service tech is working on an Amana gas pac m/n...

    Service tech is working on an Amana gas pac m/n PGB481352A
    Burners fire and run good with cover off. As soon as cover is put back on you can here burners popping like it is starving for air so he...
  24. Replies
    7
    Views
    927

    I order mine from Baker Distributing

    I order mine from Baker Distributing
  25. Replies
    33
    Views
    3,007

    3 feet of duct straight off the front of unit...

    3 feet of duct straight off the front of unit with grill at end. (straight shot)
  26. Replies
    33
    Views
    3,007

    Lets just say If we had a dirty coil then evap...

    Lets just say

    If we had a dirty coil then evap coil would start to freeze and work its way back to the cond unit. (right)

    What would make one start to freeze from the compressor and work its...
  27. Replies
    33
    Views
    3,007

    77 degrees outdoor temp

    77 degrees outdoor temp
  28. Replies
    33
    Views
    3,007

    No return duct, filter on end of unit only 3...

    No return duct, filter on end of unit
    only 3 feet of supply duct.
  29. Replies
    33
    Views
    3,007

    Starts icing from compressor, coil is not iced at...

    Starts icing from compressor, coil is not iced at that time but will eventually ice as it works it way backward.

    unit hangs from ceiling in small storage room closet only way to remove coil is to...
  30. Replies
    33
    Views
    3,007

    Sounds like a dirty indoor coil, or an oversized piston

    I was thinking oversized piston or not seating properly.
    seems that would flood the liquid back but then got to thinking that would probably give me a higher suction pressure.
    what do you think...
  31. Replies
    33
    Views
    3,007

    measured suction temp 4 inchs from suction...

    measured suction temp 4 inchs from suction drier,(no pressure drop across drier, also has liquid line drier.
    pulled piston looked alittle big but no numbers on it.

    air handler about 7 years old
  32. Replies
    33
    Views
    3,007

    line temp suction 30 deg, liquid 83 deg. ...

    line temp suction 30 deg, liquid 83 deg.

    you can force liquid in it but suction pressure does not go up.

    there is liquid in the suction line, just loosen gauge hose
    and it ices up as liquid...
  33. Replies
    33
    Views
    3,007

    I went on a call, 5 ton split system. Pressures...

    I went on a call, 5 ton split system.
    Pressures 53/165 line temp 30/83
    return air 78 deg supply 56 deg
    piston metering device, 1 1/8 suction line for about 30 foot run.
    Low suction and head...
  34. Thread: Reversing Valve

    by cybarr
    Replies
    8
    Views
    4,897

    Copeland hermetic compressor CRN5-0500-TF5-970

    Copeland hermetic compressor CRN5-0500-TF5-970
  35. Thread: Reversing Valve

    by cybarr
    Replies
    8
    Views
    4,897

    coil is energizing but i dont notice any reaction...

    coil is energizing but i dont notice any reaction from valve. I don't feel or hear it moving inside.

    If the valve was stuck half way wouldn't there still be some differance in pressure.
  36. Thread: Reversing Valve

    by cybarr
    Replies
    8
    Views
    4,897

    search

    is there a way i can search thru the posts on this site
  37. Thread: Reversing Valve

    by cybarr
    Replies
    8
    Views
    4,897

    This is an Addison 5 ton package Heat Pump....

    This is an Addison 5 ton package Heat Pump.
    Question if a reversing valve is stuck in the middle would the pressures be equlized when running.
    When I turn on the unit there is no change in high or...
  38. Replies
    11
    Views
    1,138

    no fan control fan blade ok (big and heavy) no...

    no fan control
    fan blade ok (big and heavy)
    no voltage drop
    cleaned coil before i installed motor
  39. Replies
    11
    Views
    1,138

    The motor was a magnetek 741 1/2hp 825rpm max...

    The motor was a magnetek 741
    1/2hp 825rpm max amps 3.5 60C Ambient
  40. Replies
    11
    Views
    1,138

    New motor

    I installed a new motor in this unit called for a
    1/3hp 825rpm 2.6 amps
    the 1/3hp that the supply house had only rated at 2.3 amps
    so I opted for a (1/2hp 825rpm 3.2amps)
    motor ran fine only drew...
  41. Replies
    11
    Views
    1,138

    Copeland Model CSAM-0300-TAC-001 Need to know...

    Copeland Model CSAM-0300-TAC-001
    Need to know what fan motor goes in it (Hp and amps)
    Someone had replaced it before with a 3/4hp 3-speed
    blower motor


    This is a condensing unit for a walk...
  42. Replies
    11
    Views
    1,138

    Copeland Model CSAM-0300-TAC-001 Need to know...

    Copeland Model CSAM-0300-TAC-001
    Need to know what fan motor goes in it (Hp and amps)
    Someone had replaced it before with a 3/4hp 3-speed
    blower motor.