    Majestic parts

    As a former Majco dealer I am concerned about my old Majestic fireplace customers. I left Majestic several years ago because they were having alot of problems and those problems were effecting my...
  2. Replies
    1
    Views
    755

    Installing a direct vent stove in the basement...

    Installing a direct vent stove in the basement for supplmental heat is a good idea. One of the draw backs is heat rises and it will go up an open stairway. Beats being cold in the basement. The other...
  3. Replies
    6
    Views
    2,220

    Steve the cold climate sw will do very little to...

    Steve the cold climate sw will do very little to stop your cold air issue. The person recommending you run the pilot did qualify that it only helps with a cold glass issue not the cold air issue you...
  4. Replies
    19
    Views
    4,165

    The only way you can get 90+% from a vented gas...

    The only way you can get 90+% from a vented gas burning fireplace would be to have a secondary heat exchanger in it and a water collection and disposal system on it. Also it would need to be power...
  5. Replies
    6
    Views
    2,220

    There is a construction issue with the chase...

    There is a construction issue with the chase around the fireplace. The cold climate switch is used to keep the chimney warm enough in extremely cold weather to maintain draft.
  6. Replies
    30
    Views
    10,275

    I won't sell them but, I won't park the car in...

    I won't sell them but, I won't park the car in the living room and let it run either.
  7. Thread: btu

    by firebug1
    Replies
    8
    Views
    945

    Your question is too vague. There is a big...

    Your question is too vague. There is a big difference between gas log and gas fireplace. Which is it?
  8. You will want to choose the Contractor that...

    You will want to choose the Contractor that preformed a Mannual J load calculation and was willing to show it to you and explain it. I would choose the zoning system to solve the one room temp....
  9. Replies
    12
    Views
    4,325

    In a pinch I have inserted a long drywall screw...

    In a pinch I have inserted a long drywall screw to hold the two pieces together.
  10. Replies
    10
    Views
    1,107

    If it has an oxegen sensor on it all bets are...

    If it has an oxegen sensor on it all bets are off. It's a vent free. I don't know alot about them, other than I wouldn't have one.
  11. Replies
    10
    Views
    1,107

    If the log set is vented. I would make sure the...

    If the log set is vented. I would make sure the pilot and main burner orfices are L.P. rated. It sounds silly but. You may have a propane burner with a natural pilot. A give away is the pilot would...
  12. Replies
    38
    Views
    4,153

    What an great idea. How is it working for you?

    What an great idea. How is it working for you?
  13. Replies
    4
    Views
    2,953

    If you can't get the milivoltage reading up,...

    If you can't get the milivoltage reading up, checking the valve won't do alot of good. You need 500 mv in the off cycle and it would be nice to have 200-250 mv under load. May be generator position...
  14. Replies
    1
    Views
    1,081

    The instruction manual will have that clearence...

    The instruction manual will have that clearence in it. Tipically it is 36" to combustables above the termination.
  15. Replies
    7
    Views
    2,364

    With the info I read. I believe you can have a...

    With the info I read. I believe you can have a gas insert installed without doing anything more to the existing unit. As previously mentioned. You will need gas, power and two liners. Then your good...
  16. Replies
    9
    Views
    2,011

    need more info.

    need more info.
  17. Replies
    19
    Views
    4,165

    The market already has a high eff. gas fireplace...

    The market already has a high eff. gas fireplace in fact it's 100%. Why reinvent the wheel. It's called vent free. personally I don't like them.
  18. Replies
    3
    Views
    4,785

    Was a dealer for several years. Then Majco was...

    Was a dealer for several years. Then Majco was sold to CFM and shortly after they purchased Vermont Castings (late 90's I believe) that's when it really got bad.

    I became a Heat & Glo platium...
  19. Replies
    4
    Views
    907

    Ditto Hearthman. Most gas fireplaces are AGA...

    Ditto Hearthman. Most gas fireplaces are AGA certified. That means they were tested and certified as a system and cannot be modified without retesting. You would be accepting all liability youself if...
  20. Replies
    9
    Views
    4,267

    It happens more than you know. Usually it will do...

    It happens more than you know. Usually it will do it as it heats up and cools down. There are a few thing you can do.

    Majestic had a problem like this once. They sent a kit that included a...
  21. Thread: gas wiring

    by firebug1
    Replies
    22
    Views
    1,987

    If you can put the smoke back in the gas valve it...

    If you can put the smoke back in the gas valve it is easy.
  22. Thread: Fan Problem

    by firebug1
    Replies
    13
    Views
    778

    I am new to techtalk and I'm more interested in...

    I am new to techtalk and I'm more interested in the marketing forums than the service. How do I get qualified for what I want?
  23. Replies
    28
    Views
    4,522

    The reason I suggested the contractors supply...

    The reason I suggested the contractors supply mannual J is to keep them honest. One may have done it and the other may have gotten lucky. I choose the one that does the work over lucky any day.
  24. Replies
    11
    Views
    6,353

    As a contractor I would discount a demo if I...

    As a contractor I would discount a demo if I wanted to get rid of it. I would have no problem with a full warranty. Don't push your luck by asking for the moon let the guy make a living and he will...
  25. Replies
    28
    Views
    4,522

    It sounds like both are close in equipment and...

    It sounds like both are close in equipment and there is not enough difference from that point of view. Ask both of them for thier Mannual "J" Load calculations to support thier equipment selection....
  26. Replies
    23
    Views
    3,124

    If the evaluation is the same. How can it biased?...

    If the evaluation is the same. How can it biased? If the solutions are different, that could be biased. If the solutions are the same and the brand of equipment choices or offerings are different,...
  27. Replies
    17
    Views
    861

    The question is what are you buying? Are you...

    The question is what are you buying? Are you buying brand, if so they are all pretty much the same. Warranty might be the determining factor. Are you buying a Contrator that will size it properly,...
  28. Replies
    6
    Views
    532

    If you are that uncomfortable if the the...

    If you are that uncomfortable if the the mechanical contractor that your General uses. Request your own HVAC contractor. There is nothing saying you can't request another Co. The down side is you...
  29. Thread: Permits

    by firebug1
    Replies
    4
    Views
    1,102

    In my area I carry a Mechanical licence and it is...

    In my area I carry a Mechanical licence and it is required by the state or local authoity to pull permits and you should only include the equipment you install on that permit. If a fireplace is...
  30. Wow I can't believe that!

    Wow I can't believe that!
  31. Replies
    6
    Views
    8,246

    You are probably right about no or poor...

    You are probably right about no or poor insulation. The only proper way to fix the problem is to take the siding off the back of the dog house and insulate and drywall the inside. In the mean time,...