  1. It's got oil in it. Is this your first compressor...

    It's got oil in it. Is this your first compressor change out? Adding more oil is a bad idea, there will already be some oil left in the system from the old compressor and the new compressor has...
  2. That guy is like nails on a chalkboard

    That guy is like nails on a chalkboard
  3. Replies
    7
    Views
    239

    Maybe a Stupid question but do gas techs only...

    Maybe a Stupid question but do gas techs only work on furnaces and gas piping? It's July I'm not thinking about heat exchangers right now it's all about the air conditioners.

    I use combustion...
  4. X2, I like how he opens that nice meter case to...

    X2, I like how he opens that nice meter case to show nick his shiny new meter. I have to fast forward through most of it, I can't take more than a couple minutes.
  5. Thread: 422D Pressure

    by jtrammel
    Replies
    5
    Views
    183

    Your liquid line temp is below/equal to ambient?...

    Your liquid line temp is below/equal to ambient? Thermometer accuracy?
  6. Replies
    115
    Views
    3,833

    I just use the 24v speed taps on the x13 to power...

    I just use the 24v speed taps on the x13 to power relay coil and break one leg of high voltage from high volts that go to x13. It's easy peasy.
  7. Replies
    7
    Views
    296

    I've got one, it worked twice and since then...

    I've got one, it worked twice and since then won't pick up the optic cable, it's says its unplugged. It worked ok the 2 times I used it. Never sent it in to be fixed, it's probably still under...
  8. Replies
    12
    Views
    346

    They make packaged heat pumps too.

    They make packaged heat pumps too.
  9. Replies
    18
    Views
    402

    Pricing isn't allowed

    Pricing isn't allowed
  10. Replies
    8
    Views
    152

    It may be under warranty

    It may be under warranty
  11. If you have .8 measuring from the return plenum...

    If you have .8 measuring from the return plenum and on the outlet of the evaporator coil that does not include the coil. Supply measurement should be after the furnace and before coil for TESP....
  12. Replies
    18
    Views
    402

    If the wall inside is 9' and the length of the...

    If the wall inside is 9' and the length of the house is 70' it would 630sqft of wall area. I would just count the wall adjoining the garage as an outside wall because that program doesn't give you as...
  13. Replies
    18
    Views
    402

    I bet a true honest load calc wouldn't be over 3...

    I bet a true honest load calc wouldn't be over 3 tons for the whole house (man j's are liberal on sizing by default)
  14. See if reference # 4593844 is what you're looking...

    See if reference # 4593844 is what you're looking for. The best way is to put in as little info as possible and then go back add a little to narrow it down
  15. Replies
    18
    Views
    402

    You can do one here for free...

    You can do one here for free http://www.loadcalc.net
  16. Replies
    12
    Views
    346

    IMO, I don't really like trane or carriers gas...

    IMO, I don't really like trane or carriers gas pack and I'm not familiar with lennox's gas pack.
  17. Replies
    12
    Views
    346

    York/Coleman/Luxaire are the same (owned by...

    York/Coleman/Luxaire are the same (owned by Johnson controls) they are one of if not the only gas pack that the heat exchanger is not in the cold air stream to prevent it from rusting out in short...
  18. X2, stay safe kefah!

    X2, stay safe kefah!
  19. Replies
    8
    Views
    152

    If the G wire is hooked up like its supposed to...

    If the G wire is hooked up like its supposed to be then there's a problem with the thermostat, the g wire itself or circuit board/fan relay. A tech should be able to figure it out and fix the...
  20. Replies
    12
    Views
    346

    I agree with Udarrell above.

    I agree with Udarrell above.
  21. Replies
    115
    Views
    3,833

    Nordyne is the only one we have trouble gettings.

    Nordyne is the only one we have trouble gettings.
  22. Replies
    12
    Views
    346

    I prefer the York/Coleman/Luxaire gas pack.

    I prefer the York/Coleman/Luxaire gas pack.
  23. It could be that your old system was a nominal 2...

    It could be that your old system was a nominal 2 ton and was rated as such 24000btus/hr of heat removal, now your new "high efficiency" nominal 2 ton unit is only rated to remove 20,000btu/hr. If the...
  24. Replies
    5
    Views
    208

    X2

    X2
  25. There's no way to tell that I know of. It may...

    There's no way to tell that I know of. It may last 5 years it may last 30 years.