Search:

Type: Posts; User: absrbrtek

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds; generated 50 minute(s) ago.

  1. Replies
    90
    Views
    6,578

    Do I get a courtesy reach around? LMAO :) Ya I...

    Do I get a courtesy reach around? LMAO :) Ya I got tired of hearing how bad the union is, so I put a different spin on the post 5 years ago. I figured it was time to drudge it up from the dead!!
  2. Replies
    90
    Views
    6,578

    Still Sucks to be Union 5 Years Later!!!

    Pay is now $49 an hour. $100 per vested year retirement and $6.50 in the annuity. God it sucks to be union!!!! I really feel guilty about 37 years in the field and never being out of work and...
  3. Replies
    3
    Views
    1,134

    http://www.mcscontrols.com/Compressors/compressors...

    http://www.mcscontrols.com/Compressors/compressors.htm
  4. Replies
    38
    Views
    3,020

    You can thank IR for all that fun stuff. First...

    You can thank IR for all that fun stuff. First thing they did when they aquired Hussmann was cut out quality control. We got stuff in with no fan decks, wrong txv's, no wiring, etc. Still had the...
  5. Replies
    10
    Views
    1,088

    Why? If there no pressure drop across the...

    Why? If there no pressure drop across the suction drier why bother. It is not hurting anything sitting there. JMHO
  6. Replies
    14
    Views
    1,391

    The technical term is called carbon...

    The technical term is called carbon tracking/arcing. I think off the top of my head its 1 megohm per 1000 volts is the minimum needed. Ive had 460 volt compressors that were flooded with water run on...
  7. Replies
    5
    Views
    600

    Ive bid plenty of them. Make sure you have a pre...

    Ive bid plenty of them. Make sure you have a pre existing condition clause in the contract. Everything you see that is suspect gets written up and changed at the customers expense. Try to exclude...
  8. Replies
    1
    Views
    456

    Look thru here....

    Look thru here. http://www.mcmaster.com/#ball-joints/=9lbn4w
  9. Replies
    84
    Views
    25,980

    I still think of the good times we had together...

    I still think of the good times we had together almost daily. Still pretty bumbed about it.
  10. Replies
    12
    Views
    1,611

    Is it missing the restrictor in the line?

    Is it missing the restrictor in the line?
  11. Replies
    12
    Views
    1,054

    Did you split the coil?

    Did you split the coil?
  12. Replies
    7
    Views
    1,210

    They are members of the Chillergroup....

    They are members of the Chillergroup. http://www.waldinger.com/ They seem to be a good company from what I can tell.
  13. Replies
    141
    Views
    16,560

    UA Local 420 Philadelphia

    UA Local 420 Philadelphia
  14. Replies
    11
    Views
    1,718

    They jacked me around on the ph with a molybdate...

    They jacked me around on the ph with a molybdate inhibited machine. Went on for a month, add this, add that. Total bs, never again. Rocky Research is the only one Ill use. Thompson labs was good in...
  15. Replies
    11
    Views
    1,718

    Analysts Inc?

    Analysts Inc?
  16. Replies
    4
    Views
    757

    Pilot positioner....

    Pilot positioner. http://cgproducts.johnsoncontrols.com//CAT_PDF/1921035.PDF Yours is Landis and Gyr which is now Siemans.
  17. Thread: Sporlan HGB

    by absrbrtek
    Replies
    4
    Views
    694

    It works like any hgbp valve. Turn the allen...

    It works like any hgbp valve. Turn the allen screw in or out to set you pressure. Its just a remote setpoint bulb in which the bulb needs to be mounted in a stable temp. Bulb location does not...
  18. Thread: COPELAMETIC

    by absrbrtek
    Replies
    2
    Views
    630

    See page 8....

    See page 8. http://www.carlylecompressor.com/Files/Carlyle_Compressor/Local/US-en/oem_bulletins/118.pdf
  19. Replies
    6
    Views
    1,143

    They are usually the phone extenstions of the...

    They are usually the phone extenstions of the person that designed the board, equipment or function. I found that to be an interesting tidbit. The 1380 is a "Y" for York.
  20. Replies
    19
    Views
    1,492

    Dont by IR it is trash. I just pulled out a 15 hp...

    Dont by IR it is trash. I just pulled out a 15 hp IR screw that was well maintained and less then 3 years old. Also a 5 hp. Real junk IMO. Oil leaks you could never find, etc. We put in Gardner...
  21. Replies
    5
    Views
    656

    I tyhink you'll find you get more capacity out of...

    I tyhink you'll find you get more capacity out of the coil with cw over dx. Its going to be a matter of how it is reheadered and flows. I went over this years ago with a coil manufacturer. JMHO
  22. Replies
    12
    Views
    1,811

    http://www.ptsco.com/fan_shafting.html

    http://www.ptsco.com/fan_shafting.html
  23. Replies
    5
    Views
    904

    Good company. Im currently doing an overhaul for...

    Good company. Im currently doing an overhaul for them in DE. Ive known them personaly for about 12 years.
  24. Replies
    7
    Views
    3,569

    In a nutshell, the compressor is moving less...

    In a nutshell, the compressor is moving less volume of gas as it unloads. Be it by frequency, guide vanes, slide valve or rendering a few cylinders out of action. JMHO
  25. Replies
    25
    Views
    2,097

    They are not a company you would want to work...

    They are not a company you would want to work for. One of those revolving door types.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event