Search:

Type: Posts; User: yanertrivr

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    6
    Views
    996

    A question about core charges

    Howdy all,
    Been awhile since I was here. I have to send about a half dozen compressors up for disposal. About an even split between Carlyle 6D, and Copeland 3hp med temp discus compressors. the...
  2. Replies
    19
    Views
    3,253

    the zip ties and the cinder block, these are the...

    the zip ties and the cinder block, these are the signs of.....

    Ahhh Hack Chooo!
  3. Replies
    7
    Views
    1,719

    The second photo, was what the engineer planned,...

    The second photo, was what the engineer planned, and I had them yard that crap outta there. We pulled a couple to send into town for some work and I learned why you don't have carpenters install you...
  4. Replies
    41
    Views
    7,409

    Well done, nice work to be sure

    Well done, nice work to be sure
  5. Replies
    21
    Views
    2,253

    tough chickens to be sure

    tough chickens to be sure
  6. Replies
    5
    Views
    783

    I will post before and after pics for the wall of...

    I will post before and after pics for the wall of shame
  7. Replies
    5
    Views
    783

    Ice, that has basically been my position but we...

    Ice, that has basically been my position but we are talking about engineers here especially the ones that work for this company. I could tell you tales of woe from now until the next decade. Of...
  8. Replies
    5
    Views
    783

    I'll try again, I have always set them at a right...

    I'll try again, I have always set them at a right angle to the long axis myself, I even have a couple with barely 4 " on the ends that seem to be doing fine, but that is neither here or there. It...
  9. Replies
    5
    Views
    783

    Evaporator install

    I am having an arguement with our engineering dept:argue: , I have a system with a BESA035L6-IT3B cond unit 3.5 hp 19810btu/hr , Bally BLP317LE-S2B-ECM in the larger room, bally BTL099LE-S2A center...
  10. Replies
    19
    Views
    2,573

    Looks like you need a red sled!

    Looks like you need a red sled!
  11. Check into American van, they have several...

    Check into American van, they have several different configurations of tank towers and they work very nicely, clean and functional
  12. Replies
    5
    Views
    803

    Thanks for the info, I guess it's a moot point...

    Thanks for the info, I guess it's a moot point since the company engineers wanted to buy the cool logic temp control with sensors total cost $1500.00 for a food freezer with a 3 hp condensing unit,...
  13. Replies
    8
    Views
    4,963

    Efel harmony is the ticket

    I would go with an Efel Harmony, depending on the size, while they aren't overly cheap they are a solid performer and very efficient, and relatively cheap to run, burning between 1/10 gph to 1/4gph...
  14. Replies
    16
    Views
    6,618

    Dongan used to make one, it wasn't cheap either...

    Dongan used to make one, it wasn't cheap either but it would tell you the output voltage not just say good or bad. Of course the arc test is pretty good as long as the arc will stretch at least an...
  15. Replies
    48
    Views
    3,690

    Options abound. For pants look at Bailey's...

    Options abound. For pants look at Bailey's woodsman supply for their 'wild ass' jeans, just about a good as carhartts were and about half the price. even come with bachelor buttons. They are at least...
  16. Replies
    5
    Views
    803

    I could see that in a larger scale operation,...

    I could see that in a larger scale operation, even in my compressor room it might be nec, but it already has a fresh air make up to regulate temperature. I mean this is just a step above a mom and...
  17. Replies
    5
    Views
    803

    Refrigerant monitor question

    Does anyone know the MEC code reference that would state what equipment size, charge size and or what would qualify the need for a refrigerant monitor. I primarily deal with small to mid size...
  18. YEah I tried one of those. used a lite coat of...

    YEah I tried one of those. used a lite coat of oil like the Carlyle manual said. Leaked like a sieve, so i got a different fiber type gasket and did the same thing and viola' fixed. So now after...
  19. Since I don't have an OEM gasket- it will take a...

    Since I don't have an OEM gasket- it will take a minimum of 1 year to get(gotta love a multi-national Corp) for the discharge service valve-different unit now, needs a hot gas bypass valve and has a...
  20. The big prize is the left bank, But I changed...

    The big prize is the left bank, But I changed them all-they had the spares and we're back online. Looks like this will be another season of hot gas solenoid valve replacements as well. These are in...
  21. Definite bad valves, the cch went south and they...

    Definite bad valves, the cch went south and they didn't pre heat it before starting. I've never worked much on one of these Carlyles, they are solid and simple no wonder they last for a long time....
  22. 06 Carlyle bad valves on a Carrier Transicold Electra.

    Got a 6 cyl that has bad valves, makes a heckuva racket in defrost. I'm thinking I'll just pop the heads off and change the valve plates and see how that goes before I think of changing the...
  23. Replies
    34
    Views
    2,144

    You have right Cube, They make as good as...

    You have right Cube,
    They make as good as basically anyone else, why cap tubes? Lower cost per unit, and if the work is done right they do last along time. I have some in my area that have lasted...
  24. Thread: 502

    by yanertrivr
    Replies
    32
    Views
    2,797

    Well I agree with those that say R404A, if you...

    Well I agree with those that say R404A, if you are replacing the compressor. Is this low temp or medium temp, Could go with R507 in a medium temp,I hear it uses more electricity in freezers than in...
  25. Replies
    19
    Views
    3,412

    impressive, low bidder?

    impressive, low bidder?
  26. Thread: Torch setup

    by yanertrivr
    Replies
    28
    Views
    2,905

    I like the smith tips also they rock in close...

    I like the smith tips also they rock in close quarters.
  27. Replies
    22
    Views
    1,703

    The first 2 photos are of the mechanical space i...

    The first 2 photos are of the mechanical space i the arch-a bit of a joke but it is what it is, the second is of the engineering design calling for a 24" round duct to pull fresh air into the...
  28. Replies
    7
    Views
    1,719

    true enough, they don't always run but while I...

    true enough, they don't always run but while I was out there on a couple of sunny days we had ambient temps of around +28F so we need a bit of supplemental help. Obviously by the scope of the drill...
  29. Replies
    7
    Views
    1,719

    Well somewhat, they all agree that we are the...

    Well somewhat, they all agree that we are the root cause along witrh the possibility that it could also be a standard climate trend that has been severely exacerbated by the massive carbon input from...
  30. Replies
    22
    Views
    1,703

    Sure my email is stevemikl@yahoo.com ...

    Sure my email is

    stevemikl@yahoo.com
    Thanks,
  31. Replies
    7
    Views
    1,719

    Yep he was into that thing here to. Good guy,...

    Yep he was into that thing here to. Good guy, glad he found something closer to home. tell him his ice machine is still waiting for him.
    Enjoy
  32. Replies
    3
    Views
    483

    Got them in the wall o pride thanks markettech, ...

    Got them in the wall o pride thanks markettech,
    Cheers
  33. Replies
    25
    Views
    4,589

    Looks good, nice to have the space

    Looks good, nice to have the space
  34. Replies
    22
    Views
    1,703

    posted pics on the wall of pride

    Finally got it sorted out, posted some pics on the wall, will post some more of some different stuff later this week
  35. Replies
    7
    Views
    1,719

    WAIS Divide Ice core camp Antarctica

    Some photos from the Ice core site

    http://i251.photobucket.com/albums/gg300/yanertrivr/DSC00644.jpg
    http://i251.photobucket.com/albums/gg300/yanertrivr/DSC00717.jpg...
  36. Replies
    0
    Views
    1,088

    Compressor room on ice

    Here are some photos of my mech room circa 1998

    ://i251.photobucket.com/albums/gg300/yanertrivr/DSC00753.jpg[/IMG]

    http://i251.photobucket.com/albums/gg300/yanertrivr/DSC00754.jpg...
  37. Replies
    3
    Views
    483

    got them in what next?

    got them in what next?
  38. Replies
    3
    Views
    483

    Can't post photos

    what's the secret to posting photos even compressed ones, don't want to work, have some of the WAIS site and some various McMurdo stuff
  39. Replies
    22
    Views
    1,703

    Can't seem to upload pics even re-sized ones,...

    Can't seem to upload pics even re-sized ones, whazzup with that?
  40. Replies
    22
    Views
    1,703

    NZ is New Zealand, a 5.5 hr flight from here via...

    NZ is New Zealand, a 5.5 hr flight from here via C17 cargo plane. NZ has way different power, their 3 phase is 460vac, so getting OEM stuff is still an air freight issue. Re-supply will be arriving...
  41. Replies
    22
    Views
    1,703

    Hold the bus/or LC130 in this case.

    Well where to begin. for anyone wants to check a couple links try these:

    http://www.waisdivide.unh.edu/
    http://waisdivideoutreach.********.com/
    http://blogs.bootsnall.com/luke/?maps=3
    ...
  42. Replies
    22
    Views
    1,703

    Thanks, I figured that there must be quite a few...

    Thanks, I figured that there must be quite a few out there, I am stuck as the closest supply house is about 12,000 miles away and we have no catalogs , not to mention a slower the campagn reform...
  43. Replies
    22
    Views
    1,703

    2 wire fan delay for a field modification

    Help...
    Ran into a bit of a problem out on the continent a couple of weeks ago, out at the WAIS divide ice core drill site. We are using Carrier-Transicold Electras for climate control in the core...
  44. Replies
    4
    Views
    730

    Hoshi 450 flaker

    Had a call on a hoshi flaker, found the plastic spout flange broken and it was pukin ice everywhere. Figure that the bin control switch went south and it didn't shut off. These are magnetic proximity...
  45. Replies
    2
    Views
    635

    I don't know for sure they went out and bought...

    I don't know for sure they went out and bought ice o matic machines and dispensers, despite what I told them. They are just too cheep. Low bid gov contractor, all about profit-cost + and delivering...
  46. Replies
    2
    Views
    635

    Scotsman SLE-400

    has anybody out there had any problems with the chinsy plastic water tray these POS? leaked right out of the box on the seam and this is the 4th one I replaced in the last 6 yrs.
    What crap, no...
  47. Replies
    32
    Views
    4,881

    Cascader, ever have the headmaster squall? I have...

    Cascader, ever have the headmaster squall? I have one that is set at 4C, and it seems to be squalling while the condenser fan is cycled off. Looks like I'll have to crack the book.
  48. Replies
    32
    Views
    4,881

    Carrier thin line

    The carrier thin lines i am dealing with here are all R134A, with arctic kits so suprise they actually have cch on them, but they have them de-energized during compressor run time< make sense I...
  49. Replies
    2
    Views
    582

    Johnson t stat

    That's the one I was looking for I think, Thanks
  50. Replies
    2
    Views
    582

    Johnson controls

    Hey all, I'm looking for a Johnson temp control that will get me a 2 C diferential and can read in either C or F, I seem to have difficulties navigating their site and since the newest catalog we...