    Well they want both digi readout, but also to...

    Well they want both digi readout, but also to setback at least once for night-sleep time ,versas the day-wake up time seting, they dont want the staff to mess with it twice a day, altough thts are...
  2. Replies
    10
    Views
    775

    they too expensive, why Pro 4000 series what...

    they too expensive, why Pro 4000 series what wrong with it?,thanks anyway.GY
  3. Replies
    10
    Views
    775

    Hello, Yes the tstat are in each zone ,2 per...

    Hello, Yes the tstat are in each zone ,2 per floor[1-3 ,1 in basmnt and 3 on 2nd fl. overall 8 tstas to be replaced, the manager sid, she wants the sleep time higher the temp by 4degres then daytime...
  4. Replies
    10
    Views
    775

    Programable THrmst in Nursing home

    I was ask by my customer to replace all thrmst to programable ,[exsitng ones are round Honw, York ,rectangle, Carrier rectangle,White rodgers rectangel, old style non progrmble], so i looked around...
  5. Thread: Insulate duct's

    by gyuri1
    Replies
    12
    Views
    1,641

    Carrier Infirnity control newer version

    I got to have replace my Infinity control from 2005 with same but i find 2 new items on it-in it rather.
    1: Switch SW3-4 : off [change at furnace] ,i odnt know what this is for in Furnace setup ....
  6. Replies
    1
    Views
    592

    Carrier Infinity Low High Furnace heat ,

    Have this MVP 58 infinity furnace system here installed 2yrs ago, all is fine i run it on Low heat selection in Furnace setup,and i checked the runtime around 19-21 minutes which includes 180 sec...
  7. Replies
    9
    Views
    927

    My installer dealer,actually speed ed up the...

    My installer dealer,actually speed ed up the system fan by adding 1/12 ton to the real 3 ton =3.5 ton i nthe infinity control when he reinstaled the condenser outside unit,so you say i shal slow it...
  8. Replies
    9
    Views
    927

    Carier Infinity -too high humididy

    Hi, I have this Infinity system installed less then 2 yrs ago, and thsi year we have pretty high humid summer [Chicago].
    My problem is : In basement fam. room have 3 reg's and they form water...
  9. Replies
    17
    Views
    5,020

    Carrier

    Doc, look iam sorry ofr youre troubles ,in fact i had some of that after the installation also, like the dusct work full of sharp 90 degres insted of 45degrees, then their boss came w/ salesman...
  10. Replies
    17
    Views
    5,020

    Carreir

    Doc, Idid recievd form Carrier a piece of warranty paper [2005 november] for how long and what is covered ,58 mvp furnace , ac coil, a/c condenser, infin. cotrol, humidifier, the whole thing the...
  11. Replies
    17
    Views
    5,020

    Carreir MVP58 bloer motor out

    Hi, I also have Carrier 58 MVP ,and few month ago i heard a loud start up noise in the small motor exhaust but after 2 minutes when the main blower and flame started it was gone ,i heard it few...
  12. Replies
    0
    Views
    428

    Carrier Infinity furn high heat on- off?

    I set in Infinty control the thermostat setting in comfort, but the heat stage i selected Low, since lots of times the furnace reved up to high heat when the setting comes up like in morning and...
  13. Thread: Insulate duct's

    by gyuri1
    Replies
    12
    Views
    1,641

    Carrier Infinity High heat off

    I set in Infinty control the thermostat setting in comfort, but the heat stage i selected Low, since lots of times the furnace reved up to high heat when the setting comes up like in morning and ...
  14. Replies
    1
    Views
    489

    Carrier Infinity control clock change?

    I tought this Infinity control changes with season ,and now since it was earlier than other years, how could we update the control?, mine is about 1 1/2 old.
  15. Replies
    8
    Views
    1,717

    Carreir Infinity Tstat updates

    Hi, There is not any update as far as Tstat Infinity control pad if would be ,how would we able to update it anyway, onl ythe techies do that if they equip ofr that ,my instaler probably are. ...
  16. Replies
    6
    Views
    876

    Infinity

    thansk guys, what is mean UI?
    The noise is not bother me so much [is not verry noisy let say],
    LAst year htey have to replace 4- 90degree elbows to 45 degre in the furnace room ,that took care of...
  17. Replies
    6
    Views
    876

    infinity staging

    jrbenny
    thanks for answering, but i do let now to do the "system" do the staging, i tried "furnace" for night, and it always was high stage in service- read out, the duct is brand new also 1...
  18. Replies
    6
    Views
    876

    I have this unit for a good year,runs alright, i...

    I have this unit for a good year,runs alright, i had set the staging for low since it used to rev up when the new setting came on ,techie told me i should set it to low, now is cold here midwest...
  19. Replies
    12
    Views
    3,245

    Fan speed Infinity

    I have Infinity Carrier here ,and i keep running the fan only on low morning and afternoon-eve .
    I tryed the med and high speeds and mine is responding to it properly ,maybe something is wrong...
  20. Replies
    11
    Views
    1,303

    Carrier infinity

    seadragon
    In my furnace -control i turn of the high heat -2nd stage,yo ucould do that in the control in furnace setting area,iam in chicago, so i dont need high heat ,it used ot ramp up...
  21. Replies
    11
    Views
    1,303

    Carrier infinity

    melzee
    I have Carrier Infinity here also, if the fan setting is on Auto, the fan should not run, but if the comfort level is set
    then the system comes on 90 minutes before setback is set to, and...
  22. Replies
    4
    Views
    866

    Bryant info

    Do you have a website about thsi unit fro mBryant please ?
  23. Replies
    4
    Views
    866

    My friend had instaled this Bruyant a/...

    My friend had instaled this Bruyant a/ condeser:
    113RNA042-A ,TXU nor the SEER rating,
    also the coil on air handler Bryant was repaced and the linset,
    also i did not know if it s Puron or...
  24. Replies
    6
    Views
    944

    Thorton, infinity brings fresh air in only for...

    Thorton, infinity brings fresh air in only for heating to combustion chamber,it recirculates inside air only, i understand to open windows which i often do when is not ot hot -humid...
  25. Replies
    6
    Views
    944

    Have here Carrier Infinity MVP 58 system less...

    Have here Carrier Infinity MVP 58 system less than year old, -dutcs also new, and after few days high humidity temp 90F, i staring to smell like the dirty socks, after coling condenser is off...
  26. Guys today we have here cooler day and low...

    Guys today we have here cooler day and low humidity, and the furnace room is ok, altough the system didnt kicked on yet the whole day i keep it at 80F, so its ok, i guess icould dod that what you...
  27. billb7581 thanks what you mean it dont mean ...

    billb7581 thanks what you mean it dont mean nothing if no return there ,should i have an suply register there maybe?,ima measuring the temp there is around 78-80F, RH 65-70%, no laundry was done ...
  28. Bilb i understand whats this is, but i didnt...

    Bilb i understand whats this is, but i didnt spent $$$$$$$ for thsi system ,that i shal run another dehum motor w/ noise making agian, i measuring the humidity there and is 70%,
    hte system is...
  29. billb7581 talking none sense, I keep the door...

    billb7581 talking none sense, I keep the door open, and i have outside the door inhallway 3 feeet away a circle register in 6" round pipe which comes ofthe plenum i nthe furnace 14 feet away ,blows...
  30. He fellas, why get a portable dehum, when i...

    He fellas, why get a portable dehum, when i sunk a good few $$ in this new system plus new ducts also [had before radiant heat in cielings and floors] ,its just need a little tweaking, the techie...
  31. Wyonger, now for a week or moore the sytem didnt...

    Wyonger, now for a week or moore the sytem didnt even kicked on ,ok is not thet hot, in 74-77F, humid ,a little i read uo by tstat 51-52%, doen here 60%, temp 74F, ok ,my setting is daytime 81F, eve...
  32. They didnt install since just outside of the room...

    They didnt install since just outside of the room at landing from stairway is a 6" round register and the door is kept open to furnace room all times ,so is warm there or cool.
    I checked my tstat...
  33. Carrier Infinity sweating,driping

    Ok i talked ot the boss in the install firm, and he say is not good idea to install return ,since it coudl effect the flame in the furnace ,i said to him is sealed combustion chamber system the...
  34. Carrier Infinity sweating,driping

    Hi, I was told by instaling firm that i need a small return registry like 10by 4" o none of the return duct running here in furnace rom [also is a laundry rm adn hot water heater is there,]S otoday...
  35. Carrier 13 seer,Infinity MVP58 sweating, driping

    Ok ,the repair guy came not much knowledge of Infinity systems told me form the bat, but checked the pressure on condensing unit and temp: this is result Actual tmep 80,Super heat 38, presure 118...
  36. Carrier 13 Seer ,Infinity MVP58 sweating ,dripping

    Yes iam running fan at either low or medium speed setting all day except sleep time, so yo usay if ia mrunnig fa n and no cooling is kicked on, it makes moore humidity i noticed that on my...
  37. Carrier 13 Seer ,Infinity MVP58 sweating ,dripping

    Thanks guys, the furnace room is covered w/ dryawall, no return reg or supply reg in the room ,per say, but right outside in small landing form stairs is a cieling comercial round reg which is fed...
  38. I got this system 9 month ago installed [new...

    I got this system 9 month ago installed [new ducts also] is a 3 ton Performance A/C condenser, linset 10 feet right outside the furnace room furnace is MVP58 100 with 042 coil,
    now we have prett...
  39. Replies
    6
    Views
    929

    Carreir Infinity run too long...

    wyounger Thanks for reply, i did read some of manual for Infinity control and found about dehumidification ,i had setting "cooling condenser should sometimes turn on was set to OFF, i did set it...
  40. Replies
    6
    Views
    929

    Carrier Infinity runs too long...

    Thansk for reply Dash, but i have just 1 zone 1 control on 1st floor, basmnt family room is way too cold, htere is 2 trunkline 1 longer than other also the longer with 4 45degre bends ,the shorter...
  41. Replies
    6
    Views
    929

    to satisfy the infinity control setting i.e 78F,...

    to satisfy the infinity control setting i.e 78F, also the basement family room temp [72-71F] diferential from 1st fl. is 6-7F where control is on corner to halway close to return reg.
    When a/c runs ...
  42. Replies
    16
    Views
    3,073

    I hqave an Carrier 38 TXA 036 unit instlal few...

    I hqave an Carrier 38 TXA 036 unit instlal few months ago, yes its looks liek a typo on the isntaller fella ,aho is probalby good at that but not at writing and invoice.
  43. Replies
    13
    Views
    1,683

    Do i need this feet part for just an A/C...

    Do i need this feet part for just an A/C condenser unit Carrier 38TXA unit ? ? ,we do have snow here ,but snow got in the unit also then it melts,so i guess not needed?
    If i want it , can it be...
  44. Replies
    1
    Views
    744

    I have this furnace -system for about 4 months...

    I have this furnace -system for about 4 months ,now, it works
    ok, except few problems had ,like replace the board few weeks ago [buletin recall],balance of air distributuin , its resolved,...
  45. Replies
    13
    Views
    1,683

    Hi , Is this a heat pump? i have 38 TXA 036 a/c...

    Hi , Is this a heat pump? i have 38 TXA 036 a/c condenser, i like the conical feet , were ca ni get tnhem my just sit on a plastic slab.
  46. Replies
    2
    Views
    590

    Carrier Infinity same

    Hi ,My Infinity does actually oposite ,ihave ByPAss type Carrier hum and it runs lots of water trough it hardly turns off only i set to 2 block on infinity control panel-tstat.
    I had replaced ...
  47. Replies
    16
    Views
    1,871

    Now i have similar problem , Yesterday i had my...

    Now i have similar problem ,
    Yesterday i had my installer firm to replace the powered Carrier FLP hum. to By Pass type Carrier,
    My infinity furnace sit on a return box altough the return comes...
  48. Replies
    16
    Views
    1,871

    hi I did figured out the manual setting of...

    hi I did figured out the manual setting of humidity in tstat , thansk itought mine cant doit but i see it could .
  49. Replies
    16
    Views
    1,871

    Jeff, I have carrier infinity control also my...

    Jeff,
    I have carrier infinity control also my software is alsoCESR131339-08
    on mine i cannot change % ,only in cooling humidity,
    i change heating humidity in basic- and scrol under time...
  50. Replies
    8
    Views
    1,717

    contorl board

    jamesimprl
    I am getting exact same errors,and cause getting new board this week, since i had already 3rd times false codes like 25 ,32,45 and some others and cold air blowing middle of night,...
Results 1 to 50 of 65
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event