  1. not a code thats in the book, sure it's not A437?...

    not a code thats in the book, sure it's not A437?
    that would be airflow and not an error
  2. Replies
    80
    Views
    2,594

    Prayers sent.

    Prayers sent.
  3. Replies
    9
    Views
    286

    call the installer back

    call the installer back
  4. Replies
    16
    Views
    948

    nozzles of that design have been around at least...

    nozzles of that design have been around at least 30 years that i'm aware of. i used to go out on sewer blockage calls with a friend of mine and the sewer jetter used a nozzle like that.
  5. not the right thermostat for a 2 stage furnace ...

    not the right thermostat for a 2 stage furnace

    electronic motor, not a true variable speed

    running fan all the time will usually make the house feel drafty during heating season
  6. Replies
    5
    Views
    234

    better get it looked at, sounds like it may be a...

    better get it looked at, sounds like it may be a limit tripping and killing power to stat.
    hows the air filter?
  7. Replies
    8
    Views
    600

    up flow gas furnaces are approved to sit on...

    up flow gas furnaces are approved to sit on combustible floor. you and your inspector should read the code and install instructions.:whistle:
  8. Replies
    44
    Views
    1,851

    Lennox used spark ignition in their residential...

    Lennox used spark ignition in their residential furnaces for at least 25 years before the sure-light ignitor and board was introduced. sure-light has been much more reliable than any of the spark...
  9. Replies
    7
    Views
    426

    ever try using iron-out on a rust build up like...

    ever try using iron-out on a rust build up like that? stuff is amazing. :.02:
  10. Replies
    31
    Views
    1,104

    picked up a used remington 870 on sunday 8 shot...

    picked up a used remington 870 on sunday
    8 shot tube with pistol grip and adjustable stock.

    it was too cheap to say no to..:whistle:
  11. Replies
    4
    Views
    406

    what type of ducts? as long as not flex you...

    what type of ducts? as long as not flex you should be good just running the system fan for a day to dry things out.
  12. Thread: Lennox ac

    by t527ed
    Replies
    6
    Views
    384

    blower coil or using a furnace? only way you will...

    blower coil or using a furnace? only way you will hit 16 seer is with a v drive blower.
    upflow, downflow or horizonal??
  13. Replies
    10
    Views
    672

    cooked mine upside down the whole time, perfect...

    cooked mine upside down the whole time, perfect and juicy. :grin2:
  14. a fairly small percentage of the ones we have...

    a fairly small percentage of the ones we have installed. as long as they had the new heat ex installed during the inspection program or are the G21 models most of them are still going strong.

    main...
  15. Replies
    144
    Views
    7,595

    some mags are just tough to load to capacity....

    some mags are just tough to load to capacity.
    google Butler Creek mag loader
  16. this will work most of the time.

    this will work most of the time.
  17. why?? we have many pulse furnaces still going...

    why??
    we have many pulse furnaces still going strong and pass routine pressure tests.
    OP comes here with an obvious zoning problem and gets stomped on.

    OP get someone in there that understands...
  18. Replies
    2
    Views
    338

    that system is the ideal situation for a mister...

    that system is the ideal situation for a mister style humidifier.
    we usually install them on the a/c coil cabinet with an extension tube to put the spray nozzle below the coil.
  19. Thread: Condesate Leak!

    by t527ed
    Replies
    27
    Views
    1,202

    probably a crack in the inducer that tightening...

    probably a crack in the inducer that tightening the clamp is causing to open up.

    common?? no but stuff happens. no way a plugged drain would cause a leak that high in the system.
    let them replace...
  20. Replies
    8
    Views
    498

    never heard of a code like that, been installing...

    never heard of a code like that, been installing in NJ for 45 years.

    that 2" pipe WILL freeze.
  21. Replies
    80
    Views
    4,747

    517721 Depending on the weather PX4. .40...

    517721

    Depending on the weather
    PX4. .40 subcompact
    Sig P230. .380
  22. it was gone in the mid 70's for sure. we sold...

    it was gone in the mid 70's for sure. we sold them until they went away then went to Bryant until Carrier bought them.
    sold Bryant for probably 6-7 years before going to Lennox in 81-82, been with...
  23. pretty sure the old original westinghouse company...

    pretty sure the old original westinghouse company went out of business in the mid to late 70's.
    we were selling them at the time and they just went away.

    furnace is way over the 30 yr mark, plan...
  24. Replies
    14
    Views
    738

    to add to your problems the vent going into the...

    to add to your problems the vent going into the garage violates code. as long as there is a garage door it cannot have any duct work that ties into the house system.

    maybe a window unit or mini...
  25. Replies
    14
    Views
    738

    one problem i see is if you are exhausting air...

    one problem i see is if you are exhausting air from the garage it will be replaced with outdoor air that could be more humid, causing more condensation problems.
  26. Replies
    14
    Views
    738

    how big is the piece of equipment and how much...

    how big is the piece of equipment and how much air are you looking to move?
    maybe something like a kitchen exhaust hood over the equipment ducted out a side wall.
  27. it is not a wiring issue, it is in the setup...

    it is not a wiring issue, it is in the setup menu.

    i never liked auto changeover and always set them to manual.
  28. get another price on labor to replace the HX, G26...

    get another price on labor to replace the HX, G26 is pretty easy to do. :.02:
  29. where is the duct system? if it is an attic...

    where is the duct system?
    if it is an attic system another benefit besides air filtration would be preventing condensation from forming in the cold ducts.
    a thermostat with a circulate setting for...
  30. Replies
    3
    Views
    325

    flaring block if under 3/4"

    flaring block if under 3/4"
  31. Replies
    21
    Views
    1,311

    :ditto:

    :ditto:
  32. Replies
    6
    Views
    562

    pull the cold air off the floor. :.02:

    pull the cold air off the floor. :.02:
  33. Replies
    17
    Views
    1,075

    if the manual states it must be installed as...

    if the manual states it must be installed as direct vent then that's what needs to be done.
    we have NEVER installed a 90+ furnace as a single pipe system, i don't want contaminated house air being...
  34. Replies
    6
    Views
    341

    if they are going to use filter grills then make...

    if they are going to use filter grills then make sure ALL return ducting back to furnace is 100% air tight. if not you will be pulling dirt into system after filter.
    i prefer to use filter rack or...
  35. Replies
    11
    Views
    583

    if its a single stage unit and w915 jumper on...

    if its a single stage unit and w915 jumper on board is in place it will run blower at 2nd stage settings no matter what Y terminal it is wired to.
  36. Replies
    39
    Views
    1,757

    nobody is going to rake him over the coals for...

    nobody is going to rake him over the coals for doing it.

    EVERYONE is going to rake him over the coals for talking about doing it. :whistle:
  37. Replies
    7
    Views
    458

    what tonnage?

    what tonnage?
  38. Replies
    5
    Views
    343

    water was leaking out of t instead of backing up...

    water was leaking out of t instead of backing up into pan to trip safety.
    drain lines get dirty and need to be maintained, yours is undersized and should be replaced with full size 3/4" pvc.
  39. Replies
    22
    Views
    1,617

    to use a 13 seer unit with an old cap tube evap...

    to use a 13 seer unit with an old cap tube evap coil it will have to be grossly overcharged to get the liquid pressure up high enough to feed thru the cap tube.
    it will work but it won't be right...
  40. in over 40 years i have never seen them for...

    in over 40 years i have never seen them for residential use.
    a true split system would be much more efficient.
  41. it may work with no problems, could be nothing...

    it may work with no problems, could be nothing but a big headache.
    depending on the system, coil location, ease of changing line set etc.. smart money would be replacing complete system.
  42. Replies
    6
    Views
    431

    could not find exact model # but every amana...

    could not find exact model # but every amana model with a 5 in it was a 5 ton unit.

    any #s you can read on compressor?
  43. i don't understand why you keep referring to...

    i don't understand why you keep referring to Trane as a "premium" brand ???

    you may have paid a lot for it but price alone does not equal quality.
  44. any part on that system could fail, it's a...

    any part on that system could fail, it's a machine.
    not worth worrying about.
  45. #1

    #1
  46. Lennox had some weird serial #s up until the...

    Lennox had some weird serial #s up until the 70's, that looks like one of them.

    i would plan on changing the lines.
  47. Replies
    144
    Views
    7,595

    i sent a loose dog on his way yelping the same...

    i sent a loose dog on his way yelping the same way once.
  48. as the installer and the guy who has to go back...

    as the installer and the guy who has to go back and fix it when it breaks i have always been in the habit of looking for stuff that could be a problem.
    lines touching and rubbing through each other...
  49. Replies
    4
    Views
    366

    package unit will be fully charged from factory....

    package unit will be fully charged from factory.
    needs to be checked on start up in case of a leak.
  50. Replies
    4
    Views
    366

    most units ship with charge for 15' of lineset...

    most units ship with charge for 15' of lineset and matching coil.
    installer must balance charge at start up.