11-01-2011, 06:14 PM
Thread: Alerton TX-VAV
by air j- Replies
- 8
- Views
- 1,408
If you have a programming manual for the Microset...
If you have a programming manual for the Microset I it would great if you could send it to me. Thanks
-
11-01-2011, 06:10 PM
Thread: alerton microset & microset II
by air j- Replies
- 4
- Views
- 2,275
Does anyone have the manual for the Microset I? ...
Does anyone have the manual for the Microset I? Any help is greatly appreciated.
-
11-01-2011, 06:08 PM
Thread: Alerton Microset Service Tool
by air j- Replies
- 12
- Views
- 1,752
If anyone has programming information on the...
If anyone has programming information on the Microset I can they please send it to me.
-
03-24-2011, 05:36 PM
Thread: Alerton TX-VAV
by air j- Replies
- 8
- Views
- 1,408
Yes they do have that stereo jack style plug. Do...
Yes they do have that stereo jack style plug. Do you know where I could get a microset with a cable and instructions on how to use it. They do have 3 wires to the sensors. Thanks
-
03-23-2011, 08:48 PM
Thread: Alerton TX-VAV
by air j- Replies
- 8
- Views
- 1,408
No displays simple sensors with a slide and port....
No displays simple sensors with a slide and port. I thought I could set min max setback ect. with a plug in device of some kind?
-
03-23-2011, 04:02 PM
Thread: Alerton TX-VAV
by air j- Replies
- 8
- Views
- 1,408
Alerton TX-VAV
I just got an account with 50 of these vav controllers. I assume I could plug into sensor with a laptop or palm for setup ect. I never worked with these before does anyone have any helpful info. Any...
-
02-13-2011, 05:03 AM
Thread: Do I have T-stat Problem
by air j- Replies
- 3
- Views
- 306
Keep an eye on the t stat and unit when its...
Keep an eye on the t stat and unit when its cycling off. Determine if the unit is cycling off because the t stat is satisfying or the unit is shutting before set point is reached.
-
12-11-2010, 08:25 PM
Thread: Desa fireplace thermopile?
by air j- Replies
- 4
- Views
- 1,165
Never mind found it. Thanks
Never mind found it. Thanks
-
12-11-2010, 05:24 PM
Thread: Desa fireplace thermopile?
by air j- Replies
- 4
- Views
- 1,165
The thermocouple is bad but it is fixed to the...
The thermocouple is bad but it is fixed to the pilot/ignitor assembly does anyone know where I can get a replacement?
-
12-05-2010, 12:58 PM
Thread: Desa fireplace thermopile?
by air j- Replies
- 4
- Views
- 1,165
Thanks great site
Thanks great site
-
12-03-2010, 07:31 PM
Thread: Desa fireplace thermopile?
by air j- Replies
- 4
- Views
- 1,165
Desa fireplace thermopile?
I looked at a gas vent less fireplace for a friend and the pilot is not staying lit. I tested the thermopile at 250mv max. I never work on these and I am wondering what the rating should be? Do...
-
07-01-2010, 05:17 PM
Thread: Carrier problem Accutrol Problem I think.
by air j- Replies
- 25
- Views
- 1,466
You should have replaced the header assembly and...
You should have replaced the header assembly and to cut ref. lines with a SAW is not a good idea.....
-
06-30-2010, 05:48 PM
Thread: Carrier problem Accutrol Problem I think.
by air j- Replies
- 25
- Views
- 1,466
Just cut each inlet to evap coil with snips as...
Just cut each inlet to evap coil with snips as far back to header as possible then unbraze one at a time. Hope this helps that's the way i do it
-
04-24-2010, 06:11 PM
Thread: Old Unit Size Help
by air j- Replies
- 3
- Views
- 548
looks like 2.5 ton
looks like 2.5 ton
-
02-25-2010, 03:19 PM
Thread: 1st A/C change of 09'
by air j- Replies
- 43
- Views
- 6,331
I hate to see all those wire ties on the armor...
I hate to see all those wire ties on the armor flex. Why not sleeve on the armor flex before brazing your last connection? Looks better and lasts longer.......
-
I have not been there yet but it is supposed to...
I have not been there yet but it is supposed to be older stuff.
-
Thanks any help is appreciated.
Thanks any help is appreciated.
-
Teletrol
I am servicing several buildings with teletrol controls. Does anyone know i where i can get any information and software to access this system? Any help is appreciated.
-
12-03-2009, 07:50 PM
Thread: Commercial HVAC job in central N.J.
by air j- Replies
- 2
- Views
- 432
Commercial HVAC job in central N.J.
Anyone know of any good commercial HVAC company's looking for service tech. with 10+ years experience in the central N.J. area.
-
11-15-2009, 12:07 AM
Thread: carrier 30hxc oil problems????????
by air j- Replies
- 10
- Views
- 1,733
If these are semi's may want to reverse rotation,...
If these are semi's may want to reverse rotation, sometimes oil pump will be running backwards.
-
11-06-2009, 07:25 PM
Thread: Return air grate noisy at high CFM
by air j- Replies
- 26
- Views
- 1,518
you can also bend the louvers open more . This...
you can also bend the louvers open more . This sometimes helps if sizing isn't too far off. Taped seamers is best for doing this so you don't scratch the finish.
-
08-28-2009, 07:36 PM
Thread: First Install
by air j- Replies
- 39
- Views
- 5,436
Work looks nice and neat but why the t and open...
Work looks nice and neat but why the t and open pipe after trap over furnace?
-
02-13-2009, 07:48 PM
Thread: stinky trane variable speed
by air j- Replies
- 19
- Views
- 1,467
is there an electronic air cleaner ? (ozone at...
is there an electronic air cleaner ? (ozone at low speed)
-
02-13-2009, 04:33 PM
- Replies
- 2
- Views
- 388
70 deg. loop temp in heat mode with 6 deg....
70 deg. loop temp in heat mode with 6 deg. differential.
-
02-12-2009, 07:09 PM
- Replies
- 2
- Views
- 388
AFF McQuay 40 ton water cooled rooftop heatpumps
I am working on a new account with several 40 ton (RCRM) water cooled rtus (aprox 25 yrs old) (4-10 ton comps). Several compressors have been replaced, charged in ac mode 10 deg sub cooling and 12-15...