  1. Replies
    20
    Views
    2,440

    It was the gas valve. Can't explain it not...

    It was the gas valve. Can't explain it not working in one unit but working on another. But that was it
  2. Replies
    20
    Views
    2,440

    That makes sense. I only checked it with it not...

    That makes sense. I only checked it with it not running. It does have a regulator on it. That's a very helpful suggestion.
  3. Replies
    20
    Views
    2,440

    I had 2 units down. one with a bad combustion...

    I had 2 units down. one with a bad combustion blower and igniter and one that wont light off. I had suspected the gv so I took it off the unit with bad combustion blower and it still didn't light. ...
  4. Replies
    20
    Views
    2,440

    Yes sir

    Yes sir
  5. Replies
    20
    Views
    2,440

    I actually moved the inducer, igniter and valve...

    I actually moved the inducer, igniter and valve to another unit to get it going. (it had a bad inducer) it worked fine.
  6. Replies
    20
    Views
    2,440

    voyager ignition problem

    Working on a trane voyager ycd180. Unit will not ignite. Combustion blower comes on, hsi energizes, I can smell gas through outlet of heat exchanger but doesn't try to light.

    I understand how...
  7. Replies
    6
    Views
    1,308

    cant see how this passed an inspection

    found these on a roof the other day.

    first one is of a rtu exhausting into the MUA intake.

    I wasnt aware of the add-on kit for the concentric kit.

    best part is all this work passed city...
  8. Replies
    29
    Views
    2,757

    according to payne the warranty starts from the...

    according to payne the warranty starts from the date of install if documented by invoice or permit or by registering the unit. If none of those its 90 days from the date of manufacture.
  9. Replies
    18
    Views
    3,611

    taking bets when the house falls down

    took this today in a 112 yr old house. seems they needed to cut the main beam to get that return in. you cant see the 2x6 nailed to the joist on either side of the beam to keep it from falling. i...
  10. Replies
    14
    Views
    3,079

    that was "mountain man" , he also host the town...

    that was "mountain man" , he also host the town radio show....Jack (hilarious show)
  11. i have replaced a lot of these pressure switches....

    i have replaced a lot of these pressure switches. there was a problem with a bunch of them and they make a replacement that comes with new tubing that you have to switch around
  12. Replies
    13
    Views
    2,507

    change the batteries. happened at my house a...

    change the batteries. happened at my house a couple years back
  13. Replies
    85
    Views
    6,318

    Also hate "that being said"

    Also hate "that being said"
  14. Replies
    85
    Views
    6,318

    "the ac works fine, it just doesnt blow cold air"

    "the ac works fine, it just doesnt blow cold air"
  15. Replies
    65
    Views
    4,850

    is it possible that the orfice at the condenser...

    is it possible that the orfice at the condenser is in backwards? on payne equipment they will fit in either way. i worked with a guy who loved to put them in backwards. it wasnt on heatpumps but...
  16. Replies
    19
    Views
    2,926

    i took the back of the unit off, it was an old...

    i took the back of the unit off, it was an old luxaire
  17. Replies
    19
    Views
    2,926

    well i guess he did install new equipment. i saw...

    well i guess he did install new equipment. i saw another company at his house the other day. guess i didnt get the job. i should have known i wouldnt get it when he called me an ass when i asked...
  18. Replies
    16
    Views
    2,123

    thanks guys for the nice comments. i have some...

    thanks guys for the nice comments. i have some pics of a nice modulating luxaire i did coming soon.
  19. Replies
    16
    Views
    2,123

    AC will be installed in the spring

    AC will be installed in the spring
  20. Replies
    16
    Views
    2,123

    they do require purple primer in michigan

    they do require purple primer in michigan
  21. Replies
    16
    Views
    2,123

    the drain was temporary and i needed a coupling. ...

    the drain was temporary and i needed a coupling. im going to put a condensate pump on later after the put a sink in the basement
  22. Replies
    16
    Views
    2,123

    New furnace and h/w tank install

    This is my first WOP post. Was not too happy about installing the goodman but thats what the HO wanted. New general media, and humidifier (570M). Also installed new return drop and plenum with a...
  23. Replies
    19
    Views
    2,926

    i dont like landlords

    i am putting the landlord in the wall o shame. i found four cracks like this one between two luxaire's in a rental house. landlord said i was trying to "f*** him over" & "its not that bad, give me...
  24. your sticker is crooked on the door....thats...

    your sticker is crooked on the door....thats about all. looks good
  25. Replies
    17
    Views
    5,705

    im a firm believer that media filters, clean...

    im a firm believer that media filters, clean effects etc. do a great job in helping to reduce allergens in the house. i had a customer who was severely allergic to just about everything and with a...
  26. Replies
    17
    Views
    5,705

    so you dont believe in IAQ?

    so you dont believe in IAQ?
  27. Replies
    5
    Views
    758

    2 stage smart valve

    having a problem with a honeywell 2 stage smart valve on an arcoaire NVT6125 furnace. customer had a company out for no heat call and they changed the fan board. furnace did not fire and they...
  28. Thread: heat pump

    by ductman82
    Replies
    5
    Views
    546

    are you sure the delay wasnt in the t-stat? ...

    are you sure the delay wasnt in the t-stat? certain h.p. stats will have that delay so you dont smoke the rsv.
  29. Replies
    30
    Views
    4,311

    suction press. seems low and superheat is high. ...

    suction press. seems low and superheat is high. sounds like low on charge. at 80 degree outdoor ambient suction pressure should not be at 59 psi more like 72+-. i know you said it has an orfice...
  30. Replies
    30
    Views
    4,311

    i agree too much airflow. or ive seen installers...

    i agree too much airflow. or ive seen installers put the orfice in backwards and it cause press. fluctuations.
  31. Replies
    41
    Views
    3,595

    i think its an airflow problem. suction pressure...

    i think its an airflow problem. suction pressure is too high for 78 outdoor ambiant. slowing the blower down will drop suction pressure and increase delta t. or may be a loose sensing bulb on the...
  32. Replies
    5
    Views
    520

    what size blower in the furnace?

    what size blower in the furnace?
  33. Replies
    2
    Views
    840

    no not really a question as much as just looking...

    no not really a question as much as just looking for an opinion on my measurements and or thought process. looking for more of a confidence booster i guess.
  34. Replies
    2
    Views
    840

    carrier 24acr336 question

    before anyone rips me for something or another understand that i am an installer (10 years) training as a service tech and am still going through tech school.

    i had to install a new A-coil for a...
  35. Replies
    12
    Views
    1,772

    all of my equipment is brand new. i borrowed...

    all of my equipment is brand new. i borrowed equipment also and had same problem. im wondering if a standard manifold gauge set is not able to achieve the 500 microns.
  36. Replies
    12
    Views
    1,772

    its a 410 system. there is no reason it cant...

    its a 410 system. there is no reason it cant handle 500 psi of nitro. a 410 coil max pressure is over 500. mitsubishi mini splits now want a pressure check of 600 psi for 24hrs. in michigan on a...
  37. Replies
    12
    Views
    1,772

    evacuation equipment problems

    my first post!!!!!

    having trouble with my evacuation equipment. im using yellow jacket 410 gauge and hoses, supco v64 vac gauge and a robinaire 6 cfm pump. Im having trouble obtaining and...
  38. Replies
    11
    Views
    3,027

    the exhaust should point straight up. the 2...

    the exhaust should point straight up. the 2 extra 90's to point it down will increase the vent length by 10' which could possibly exceed max lenght in 2"(depending on size of furnace). also...
  39. Thread: HELP

    by ductman82
    Replies
    11
    Views
    1,222

    everyone always picks on the installers, but if...

    everyone always picks on the installers, but if we didnt put em in youd have nothing to service.

    as far as tips: USE SHEARS AND CIRCLE CUTTERS!!! carpel tunnel is a *****.
  40. Thread: Payne A/h

    by ductman82
    Replies
    20
    Views
    1,607

    if the manufacturer wanted you to use the same...

    if the manufacturer wanted you to use the same matching equipment then why do they sell payne/bryant with benchmark coils as a package at some supply houses? they dont very often come with a...
  41. Replies
    13
    Views
    3,703

    daikin has a floor mount radiator style that can...

    daikin has a floor mount radiator style that can be built into a cabinet
  42. Thread: 410a

    by ductman82
    Replies
    8
    Views
    820

    i agree changing out the lineset would be best. ...

    i agree changing out the lineset would be best. i was only saying that you could reuse it because the original post implied he was going to reuse parts of the system i.e the coil or lineset and...
  43. Thread: 410a

    by ductman82
    Replies
    8
    Views
    820

    i thought the post was a 2 part question. i...

    i thought the post was a 2 part question. i didnt mean to imply that you should pull a vacuum to remove the residual oil, i meant that you can use the rx for the lineset then when you are pulling...
  44. Thread: 410a

    by ductman82
    Replies
    8
    Views
    820

    about all you can reuse is the lineset and thats...

    about all you can reuse is the lineset and thats not really recommended because usually it will be too small. but if you do reuse it you should run a can of RX-Flush through it to clean out any oil...
  45. Replies
    6
    Views
    1,300

    also depends if its a louvered door or not

    also depends if its a louvered door or not