  1. Replies
    72
    Views
    2,053

    I think the best way for you to add the correct...

    I think the best way for you to add the correct amount of R404 is to.......

    Call a company out who knows how to work on refrigerators.
  2. Replies
    72
    Views
    2,053

    YOU LOOK AT THE SAME THING YOU DO ON R22 AND...

    YOU LOOK AT THE SAME THING YOU DO ON R22 AND R410!!!!!!!!!

    FREEZON IS FREEZON!!!!!!!!!!!
  3. Replies
    24
    Views
    2,701

    why are you resistant to use an electronic...

    why are you resistant to use an electronic detector?
  4. Replies
    22
    Views
    820

    When I order it, I'll take some pictures & post.

    When I order it, I'll take some pictures & post.
  5. one per coil, but don't put a trap in the freezer

    one per coil, but don't put a trap in the freezer
  6. Replies
    22
    Views
    820

    They are adjustable settings. And you order it...

    They are adjustable settings.

    And you order it with the 7/16”-20 UNF female, Schrader depressor connection.
  7. Replies
    22
    Views
    820

    Thanks kevincompass & pherman those will do just...

    Thanks kevincompass & pherman those will do just fine.
  8. Replies
    9
    Views
    439

    Ahhh - ha! Way to go. Pipe plugs are always fun.

    Ahhh - ha! Way to go. Pipe plugs are always fun.
  9. Replies
    22
    Views
    820

    The specific application that is going to be an...

    The specific application that is going to be an issue is low-temp R-22 on a Rack.

    It's operating setpoint is 8 PSI.

    There are times during normal operation the suction pressure will dip below 8...
  10. Replies
    22
    Views
    820

    Encapsuplated low pressure controls

    Anyone know of an encapsulated low pressure control that cuts out lower than 5 PSI?

    The lowest settings I can find is cut out/cut in 5/20 PSI.

    The only option I can find is going to the...
  11. Replies
    9
    Views
    439

    Since it's isolated down to one case. Maybe...

    Since it's isolated down to one case. Maybe you've got a pipe plug bouncing around inside the pipes of the 4 door.
  12. Replies
    4
    Views
    231

    leaving the bypass time unset leaves the manual...

    leaving the bypass time unset leaves the manual bypass value until it is manually put back to no bypass.
  13. Replies
    13
    Views
    784

    Sounds like it's time to just start changing some...

    Sounds like it's time to just start changing some parts on this thing!
  14. anyone know WHY manufactures recommend a 20*...

    anyone know WHY manufactures recommend a 20* MINIMUM?
  15. Replies
    6
    Views
    310

    Sounds like there is a large air heat reclaim...

    Sounds like there is a large air heat reclaim coil.

    Ideally, the reclaim coil will just de-superheat the refrigerant gas going through it.

    But in real life, the reclaim coil will also begin to...
  16. Replies
    6
    Views
    374

    To answer you, I'll give you a multiple choice. ...

    To answer you, I'll give you a multiple choice.

    A) Yes
    B) No
  17. You need to have the Rack filter/drier's...

    You need to have the Rack filter/drier's replaced, let it run 48 hours, then replace them again. Use high water capacity cores.

    Then of course, figure out where this moisture came from & how it...
  18. The problem is, you did some funky test in a lab....

    The problem is, you did some funky test in a lab.

    Do a real life experiment with a torch & pipe.

    One with CO2 & one with N2.
  19. Replies
    54
    Views
    1,616

    why is a legitimate method used by major OEM's of...

    why is a legitimate method used by major OEM's of keeping liquid pressure up during an off cycle considered a scab route?
  20. Replies
    54
    Views
    1,616

    I guess just throw the LPC away, wire nut it &...

    I guess just throw the LPC away, wire nut it & install a t-stat/sol with headmaster...is this what we're getting at here?
  21. Replies
    54
    Views
    1,616

    This is the control I've seen on HeatCraft units....

    This is the control I've seen on HeatCraft units.
    ...
  22. Replies
    54
    Views
    1,616

    Just curious, how would you intend to restart the...

    Just curious, how would you intend to restart the system automatically after a pump-down on a -20* night?
  23. Replies
    54
    Views
    1,616

    Here is a leading manufacture explaining it on...

    Here is a leading manufacture explaining it on Pg.2

    https://opi.emersonclimate.com/CPID/GRAPHICS/Types/AEB/ae1234.pdf

    & here is Bohn on Pg.4 listing a heated/insulated receiver with TD relay as...
  24. Replies
    54
    Views
    1,616

    The problem isn't maintaining a minimum head...

    The problem isn't maintaining a minimum head pressure while running, the problem is starting after an off cycle.

    You could install a time-delay which bypasses the LPC on start up & allows the...
  25. Replies
    46
    Views
    2,692

    one of the same things about HVAC & Refrigeration...

    one of the same things about HVAC & Refrigeration is........

    you take the same amount of tools out of the truck.