  1. Replies
    29
    Views
    1,203

    Love this pump. My company has about 20 of the...

    Love this pump.

    My company has about 20 of the oil cartridges total. When enough get dirty we refill them all at once from a gallon.

    I always keep 3-4 on the truck. These guys come in real...
  2. Replies
    23
    Views
    917

    Love mine. It's one of the least skittish scales...

    Love mine. It's one of the least skittish scales I've used. The weight will be displayed without a lot of back and forth, and is very accurate.

    The other benefit is that I think (?) it's...
  3. Since we know POE can hold onto moisture so well,...

    Since we know POE can hold onto moisture so well, do we need to revise the criteria for service work on these systems?

    For instance, on small reach-in refrigeration equipment (less than a pound of...
  4. Thread: Accutools

    by Jared Fetter
    Replies
    29
    Views
    1,219

    joeyd has always been extremely helpful with my...

    joeyd has always been extremely helpful with my questions. Highly recommended.
  5. Cool video guys!

    Cool video guys!
  6. Does ICanHas go out of his way to make things...

    Does ICanHas go out of his way to make things difficult, where it's not necessary?
  7. Glad to see things finally moving in this...

    Glad to see things finally moving in this direction. :)
  8. So after a quick skim of this thread: - No...

    So after a quick skim of this thread:

    - No point having nitrogen and CO2 on the truck. Use CO2 since it can also be used unregulated on drains, condenser coils.

    - CO2 (just regular grade from...
  9. Replies
    54
    Views
    1,793

    At 0*F ambient if the unit has been off for a...

    At 0*F ambient if the unit has been off for a while and acclimated, it will only get started if your LPC is set for cut in about 6 PSI. :eek2:
  10. Replies
    16
    Views
    1,046

    Cool, thanks!

    Cool, thanks!
  11. Replies
    16
    Views
    1,046

    Thanks for the help guys! So: Typical...

    Thanks for the help guys!

    So:

    Typical food storage (cooler): 25* SST
    Beer storage: 20* SST

    Now what about cold plate evaporators:
    1) Small reach in ice cream case/ice cream topping case?...
  12. Replies
    16
    Views
    1,046

    I have a question regarding the cap tube...

    I have a question regarding the cap tube calculator that Ice posted above.

    I'll be replacing the cap tube on a True keg cooler next week. I was going to just try and duplicate what the factory...
  13. Replies
    12
    Views
    985

    Fantastic price on the Bluvacs, I'm in. Happy...

    Fantastic price on the Bluvacs, I'm in. Happy Thanksgiving!
  14. Replies
    29
    Views
    1,584

    This is the type of system you can actually use...

    This is the type of system you can actually use your subcooling reading to tell you something.
  15. Got it - thanks! Been trying to find a 2-stage...

    Got it - thanks!

    Been trying to find a 2-stage gas with variable blower in the 40-45k range, but not all manufacturers seem to make them that small. (is the oversizing phenomena that widespread?)...
  16. Thanks for the help again guys. udarrell,...

    Thanks for the help again guys.


    udarrell, can you explain why you would want a single stage furnace with a swing t-stat - I thought this whole 2 stage/modulating furnace movement was all about...
  17. If you don't include the 2 outside walls, then...

    If you don't include the 2 outside walls, then shouldn't the 2 inside walls be included? If so, what input should be used on the calculator?
  18. Hmmm.. I'll ponder this. 40k may be enough...

    Hmmm.. I'll ponder this.

    40k may be enough for most of the year, as long as the basement thing doesn't throw everything off too far.
    I'm just really leery of oversizing, thinking that a 60k is...
  19. No problem. So that calculation I came up with...

    No problem. So that calculation I came up with was for a floor above a crawl space - you're saying a proper basement calculation would likely ADD some to my BTU requirements?
  20. I see your point. I'm not sure if there is any...

    I see your point. I'm not sure if there is any way to show this with the calculator... I don't remember seeing "partition" under the wall dropdown box.


    Yes, I'm fortunate to have that second...
  21. beenthere: I never added the garage space as part...

    beenthere: I never added the garage space as part of the "conditioned" sq ft space in my load calc. The only thing I did was add the two outside walls of the garage to the NE & NW wall load, rather...
  22. Thanks!

    Thanks!
  23. Alright guys, about ready to lay down the cash...

    Alright guys, about ready to lay down the cash for the unit. Would you go with 40k or 60k?
    According to my last load calc, I'm right between the two at 47,000.

    I have an existing 2.5 ton AC, so...
  24. What I meant is that I input the new floor...

    What I meant is that I input the new floor numbers into the calculator per Gary's post, and that changed the requirements from about 41k, to 47k. (having part of the floor on slab, the rest on crawl...
  25. Ok, plugged the numbers in and bumped the load up...

    Ok, plugged the numbers in and bumped the load up 6k to about 47,000 BTU's.

    60K furnace looks like the way to go!

    EDIT: Actually I'm smack dab in between a 40 and 60k furnace.