Search:

Type: Posts; User: guy787north

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    291

    Carrier 2nd gen zone stats

    I have 2 brand new 2nd gen zone stats still in box also lots of used 2nd gen monitor,zone and bypass stats, plus actuators,and relay packs too. Let me know what you are looking for and make a...
  2. Replies
    2
    Views
    1,736

    Climate master RTU

    Anyone know how to get old engineering data on a Climate master rtu that 30-35 years old. M#FLSR-25-260
    I need shop drawings and any other info I can get. I am guessing it`s a 25 ton unit but unsure...
  3. Replies
    13
    Views
    1,574

    Balibe: I didn't realize the pilot could be...

    Balibe: I didn't realize the pilot could be powered by the rj-25 plug. Yes if you could give me the pin configuration I will forward it on to my guys. I don't use the pilot myself, except as a time...
  4. Replies
    13
    Views
    1,574

    For that size of an equipment package I would...

    For that size of an equipment package I would recommend a computer with comfortview on it. They will find it much easier to use and you can provide them a nice graphic to go with it.
  5. Replies
    7
    Views
    2,174

    I believe the hole is to facilitate oil return....

    I believe the hole is to facilitate oil return. This is done by a venture effect. And limits the amount of oil that enters due to the size.
  6. Replies
    13
    Views
    1,574

    No software required. You can use it as is. It is...

    No software required. You can use it as is. It is a little painful to use however. I have put together a few with 3 9v batteries in a case to allow some of our tech's to access system even though...
  7. Replies
    3
    Views
    758

    getting the software is not the problem it's the...

    getting the software is not the problem it's the hardware key required to use it. Gotta go through carrier to get it.
  8. Replies
    8
    Views
    1,190

    I have talked to carrier tech support in hartford...

    I have talked to carrier tech support in hartford and they tell me they are working on an update for comfortview but don`t have any idea when it will be released. Considering all carrier ccn is built...
  9. Replies
    8
    Views
    1,190

    see the other post I put up on running...

    see the other post I put up on running confortview on vista.
  10. Replies
    7
    Views
    1,472

    Default address is 0, 140. Bypass needs to be one...

    Default address is 0, 140. Bypass needs to be one address higher than linkage co-ordinator.All other zones need to be lower than linkage co-ordinator. Linkage will look at numbers lower until it sees...
  11. Replies
    19
    Views
    749

    Tony was right there too! Can't believe I'm...

    Tony was right there too! Can't believe I'm cheering for a toyota!
  12. Replies
    14
    Views
    1,371

    I have two different usb to serial converters....

    I have two different usb to serial converters. I`m going to hook up to a controller tomorrow to see if I can get it to work.
  13. Replies
    14
    Views
    1,371

    cleancondenser You are my new hero. That could...

    cleancondenser
    You are my new hero. That could not have been easier. Yet carrier tech support today told me that they have yet to get a vista operating system to run comfortview. Hopefully they...
  14. Replies
    14
    Views
    1,371

    comfortview and windows vista.

    I am told some poeople have been able to run comfortview on windows vista even though it is not supported. I am looking for details on how this was done. My new laptop is running vista and it won't...
  15. Replies
    4
    Views
    563

    Panasonic tough books are ideal but very pricey....

    Panasonic tough books are ideal but very pricey. I just bought a new lenovo. It's my 3rd ibm. I have dropped the past ones many times and carry them up and down ladders by the screen. The newer...
  16. Replies
    10
    Views
    1,881

    I only had 9 rtu on this system. We were told to...

    I only had 9 rtu on this system. We were told to use a tcp/ip router. I was wanting to connect the rtu to a siemens sytem at another location. I could see all the devices when we connected but when...
  17. Replies
    5
    Views
    1,304

    I install 10 + vvt system's a year. Shielded wire...

    I install 10 + vvt system's a year. Shielded wire is a must especially if they are near high voltage wires. Try calibrating the space temp sensors. If it still persists you might need to replace the...
  18. Replies
    10
    Views
    1,097

    I use carrier 3v with vfd's all the time. Make...

    I use carrier 3v with vfd's all the time. Make sure your rtu will monitor supply air temp. The lennox L series maintains 55F supply air in cooling and cycles stages as req'd, Also monitors discharge...
  19. Replies
    10
    Views
    1,881

    There are two of us that are trained on the...

    There are two of us that are trained on the vfd's. We are both surprised at the level of training and information given by their training department. We were both very familar with the L series and...
  20. Replies
    10
    Views
    1,881

    Ensure all your drive settings are done as per...

    Ensure all your drive settings are done as per lennox's spec. I think they have lost alot of drives and are very specific on how they want these setup. We do start-ups for Lennox when their...
  21. Replies
    10
    Views
    1,881

    Well all I can say is that I do start ups on 10...

    Well all I can say is that I do start ups on 10 -20 L series a year, most with vfd's and whatever they charge is worth every cent. The time it saves in setting your ecto perameter's alone would pay...
  22. Replies
    10
    Views
    1,881

    The problem is not getting the software, it's the...

    The problem is not getting the software, it's the serial port to com interface they use. I tried getting one reproduced but nobody could figure out how. The software and interface are not that...
  23. Replies
    4
    Views
    558

    I set power exhaust and fresh air damper to open...

    I set power exhaust and fresh air damper to open on indoor CO2 levels. This prevents bringing in warm or cool air when it's not needed in the space.
  24. Whether I get one or not I'm super excited to...

    Whether I get one or not I'm super excited to hear back from whom ever get's one. What a great contest this was.
  25. Replies
    6
    Views
    1,582

    We install about 50 lennox rtu's per year. T...

    We install about 50 lennox rtu's per year. T class is a stripped down version of the L series. It doesn't have the IMC board. The add on factory options are limited. With the L series you can add...
Results 1 to 25 of 206
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event