  1. Replies
    21
    Views
    2,570

    This is the Problem, Subways, donuts shops, Bars...

    This is the Problem, Subways, donuts shops, Bars anyplace that has Yeast in the air.
    I use a product by Manitowoc it's called "Guardian"
    ...
  2. Replies
    16
    Views
    3,230

    This is a product of taking the low bid, this is...

    This is a product of taking the low bid, this is a new store!
  3. Replies
    16
    Views
    3,230

    He had no clue

    The contractor had his own guy... I was there to change the filters
    The Economizer, still in the unit like it was shipped, I held my camera down under the economizer to get a picture of the hack job...
  4. Replies
    4
    Views
    5,106

    Always run 100psig to the carbonator, (the co2...

    Always run 100psig to the carbonator, (the co2 pressure needs to be higher then your water pressure, if the water is more then 80psig then you need to install and water regulator on to back it off)...
  5. Replies
    6
    Views
    873

    I've had good luck with taking the old motor to...

    I've had good luck with taking the old motor to the motor shop in town and having it re-done. I saved the customer hundreds on the cost of that Hobart motor for his potato peeler
  6. Replies
    7
    Views
    921

    check lowes to replaced the fittings of Foxx...

    check lowes to replaced the fittings of Foxx equipment
  7. Thread: Anthony Doors

    by macdaddy
    Replies
    9
    Views
    2,621

    I put a plastic trap in the door opening like a...

    I put a plastic trap in the door opening like a 6x8,
    I keep 4 on the truck that way if I'm replacing the mullion heaters in a 3 or 4 door line up I can block the section off.
  8. Replies
    43
    Views
    3,328

    Oh man…I guess he didn’t save any money by not...

    Oh man…I guess he didn’t save any money by not calling a Professional.
    I have several Drills and 100’s of Bits but, I still go to the Dentist for dental work but, think of the Money I could be...
  9. Thread: Crimper

    by macdaddy
    Replies
    5
    Views
    696

    My favorite Crimps are made by T&B (Thomas and...

    My favorite Crimps are made by T&B (Thomas and Betts) model: WT 2000
    http://www.tnb.com/ps/fulltilt/index.cgi?part=WT2000
    also...
    http://www.tnb.com/ps/fulltilt/index.cgi?check=Y∂=WT110M
  10. Replies
    4
    Views
    727

    Here's the Manuals for that unit. 67822 ...

    Here's the Manuals for that unit.

    67822

    67832
  11. Replies
    15
    Views
    1,915

    This is taken from the manual Use 1/2"...

    This is taken from the manual

    Use 1/2" minimum I.D. pipe size for the incoming water supply

    line to the machine (Fig. 5). A flowing pressure of 15 to 25 psig

    must be maintained at the...
  12. Thread: Vulcan safety

    by macdaddy
    Replies
    6
    Views
    1,411

    Call a service company, because of liability...

    Call a service company, because of liability they aren't going to sell this part over the counter to the public

    A man and a woman burned in a gas explosion ...
  13. Thread: Old Cowboy

    by macdaddy
    Replies
    1
    Views
    1,082

    Old Cowboy

    An old cowboy sat down at the Starbucks and ordered a cup of coffee.
    As he sat sipping his coffee, a young woman sat down next to him.

    She turned to the cowboy and asked, 'Are you a real...
  14. Thread: Vulcan safety

    by macdaddy
    Replies
    6
    Views
    1,411

    Are you sure you got that model # right...

    Are you sure you got that model # right ?,--Model# 7860A, their Roasting ovens and are you sure about the part#....I do know of a 407798-6 --- that's a safety valve for a Vulcan-Hart unit but, I'm...
  15. Replies
    17
    Views
    3,162

    Johnstone sells a nice kit just for high temp

    Johnstone sells a nice kit just for high temp
  16. Replies
    3
    Views
    867

    Thanks for the replys I tore the electrionics...

    Thanks for the replys

    I tore the electrionics out and rewired with mechanical controls....
    Hobart didn't have any info on this, other then the operators manual that I already had that off their...
  17. Replies
    3
    Views
    867

    Hobart Blast Freezer

    I have a Hobart Quickchiller model HQC5

    It's giving me an Error message:

    Low Heater current,
    Low Fan current.
    No, It's not in defrost, it's in freeze mode
    if anyone has a Service Manual...
  18. Replies
    20
    Views
    1,433

    Hill condenser...maybe the condenser fan motor...

    Hill condenser...maybe the condenser fan motor should be a (Fasco D-800 ) which is a 1 hp motor 24"/27 pitch blade or you might find (AO Smith OHR1106) cheaper in price.
    Do they hold the doors open...
  19. Replies
    4
    Views
    639

    Try replacing the thermistor probe

    Try replacing the thermistor probe
  20. Replies
    11
    Views
    1,032

    Looks Good... just a tip that I use, I use...

    Looks Good... just a tip that I use, I use Auto-body filler on the dents and chips. Saves alot of time in sanding and OEM paint
  21. Replies
    14
    Views
    2,232

    It's called: Absorbent wick material, Wicking,...

    It's called:
    Absorbent wick material, Wicking, or Condensate wick... it comes in differant sizes depending on the size of the pan you have. This doesn't go in the evaporator pan...maybe that was...
  22. Thread: Skunks

    by macdaddy
    Replies
    29
    Views
    1,780

    This is how the Police near me took care of this...

    This is how the Police near me took care of this one time...I don't know if you want to try this, it didn't seem to work out for the police officer very well, he ended up getting fired.

    Officer...
  23. Replies
    16
    Views
    970

    You said, you checked NEC, look in Article 424.19...

    You said, you checked NEC, look in Article 424.19 he may want you to leave the circuit breaker handle lock in place.
    The Electrical Code is the MINIMUM standard...
  24. Replies
    16
    Views
    970

    The authority having jurisdiction shall be...

    The authority having jurisdiction shall be permitted to render interpretetions of the NEC (National Electrical Code) in order to provide clarification to its requirements, as permitted by 90.4 .
    He...
  25. Replies
    9
    Views
    602

    http://sporlan.jandrewschoen.com/