    i have actually worked on those trane heat pumps....

    i have actually worked on those trane heat pumps. trane is generally good equipment but they were hard to work on due to very little space. the rotary compressors are noisy in those units.
  2. Replies
    16
    Views
    4,973

    make sure you post what is wrong i am really...

    make sure you post what is wrong i am really kinda curious myself to know
  3. Replies
    16
    Views
    4,973

    there is something wrong with you unit and seeing...

    there is something wrong with you unit and seeing how i am not there to look at it, its gonna be tough for me to fix it. you said you loop had only a four degree difference, most heat pumps have a...
  4. Replies
    8
    Views
    4,519

    depending on the climate and the water...

    depending on the climate and the water temeperature open loops are more efficient but you also have to count the energy the well pump is consuming. if you run out of water or you well pump fails then...
  5. Replies
    16
    Views
    4,973

    whoever looked it obviously isn't that thorough...

    whoever looked it obviously isn't that thorough if his solution is to replace the unit. if you have a problem with your loop it will be shown in the system, low suction pressure in heating or high...
  6. Replies
    16
    Views
    4,973

    shoulldn't be putting on gauges until absolutly...

    shoulldn't be putting on gauges until absolutly necessary. i know you can tell alot about how a system feels with you hands but without putting a set of gauges on, you don't know ****, especially in...
  7. Replies
    16
    Views
    4,973

    unless you have experience in air conditioning...

    unless you have experience in air conditioning and refrigeration there isnt much you are gonna beable to do without the proper tools and know how. find a good technician to come look at it. the...
  8. Replies
    19
    Views
    3,659

    if it is locking out on high pressure in cooling...

    if it is locking out on high pressure in cooling and heating, i would say you have a bad control or the system is over charged. i have seen tx valves cause high pressure trips, but the units will...
  9. Replies
    8
    Views
    2,799

    if it was me i would drop the cut out temperature...

    if it was me i would drop the cut out temperature down to 104-106 and run cut in around 94-96, the higher the temperature you are running, the more energy you are going to consume. how big is your...
  10. Replies
    16
    Views
    4,973

    get a new tech to come look at it cause if...

    get a new tech to come look at it cause if everything is running and not heating or cooling there is definitly a problem. did he say that the compressor was running? if the compressor is running, it...
  11. Replies
    18
    Views
    3,364

    i have never heard of picking up combustabile...

    i have never heard of picking up combustabile fumes from in around the pump flanges. if this is happening and not dripping but is wet, then i would say you have a leak. when we flush ground loops, we...
  12. Replies
    0
    Views
    1,179

    climate master parts?

    trying to find a wholesaler who can get parts for a climate master heat pump that is located in canada.