    Hydro Heat Geothermal

    Does anyone know if they are still in business? Thanks
  2. Replies
    9
    Views
    1,542

    No, as far as I know all of Lennox's and anyone...

    No, as far as I know all of Lennox's and anyone else's belt driven light commercial units are single speed.
  3. Replies
    21
    Views
    1,591

    Actually I sell all my recovered refrigerant to...

    Actually I sell all my recovered refrigerant to rapid recovery. They even come to my shop and empty all of our tanks.
  4. Replies
    21
    Views
    1,591

    That's how I do it, no sense in getting out the...

    That's how I do it, no sense in getting out the recovery machine unless you really have to.
  5. Replies
    26
    Views
    2,003

    Definatly Honeywell pro series

    Definatly Honeywell pro series
  6. Replies
    37
    Views
    2,325

    Poll: Every brand has their own problems. We have been...

    Every brand has their own problems. We have been Lennox dealers for 35 years and have seen a lot of good things and some bad. As for parts prices Trane is the most expensive for parts in our area.
  7. Replies
    13
    Views
    1,630

    Yes

    Yes
  8. Replies
    13
    Views
    1,630

    I have had the gas smell issue before. It was...

    I have had the gas smell issue before. It was caused by a bad gasket on the inducer air inlet plate. I replaced the gasket an the smell went away.
  9. Thread: In floor heat

    by kms2579
    Replies
    13
    Views
    884

    You might have to upsize the pump, glycol is...

    You might have to upsize the pump, glycol is thicker and harder to pump then water.
  10. Thread: Water Hammer

    by kms2579
    Replies
    8
    Views
    777

    I would check that the zone valves are in the...

    I would check that the zone valves are in the right direction. I have seen Honeywell valves make a banging noise when they are in backwards.
  11. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    No screen was clean it just had a dimple in it,...

    No screen was clean it just had a dimple in it, kind of like a wavy appearence, which according to the factory was caused by over firing. This was the first time I worked on this unit so I don't...
  12. Thread: Boiler t-stat

    by kms2579
    Replies
    2
    Views
    322

    Any of the Honeywell focus pro or vision pro...

    Any of the Honeywell focus pro or vision pro stats will work. You'll just have to go in to the setup program and set them for hot water heat.
  13. Replies
    9
    Views
    3,358

    It's not the water same problems with them in...

    It's not the water same problems with them in Ohio. I have noticed though that Honeywell has changed the plastic on the water level sensor, we'll see how long they last.
  14. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    The burner screen is weld in between two plates...

    The burner screen is weld in between two plates that make up the front part of the heat exchanger. Trane calls the whole assembly a burner plate.
  15. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    The new burner worked great, unit fired right up...

    The new burner worked great, unit fired right up nice and smooth. Thanks to all of you for all your ideas and help.
  16. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    Heat exchanger is in good shape, and the gas...

    Heat exchanger is in good shape, and the gas valve is new, all parts are OEM replacements. After finally getting a hold of the factory tech support, local tech support was out of ideas, we came up...
  17. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    Plate on inducer is original and unit has been...

    Plate on inducer is original and unit has been operating ok for 6 years.
  18. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    It was like a delayed ignition flame shot out...

    It was like a delayed ignition flame shot out about 6in then shut off and tried to relight. Tomorrow I'm going to check orifice and amp out igniter tech support said it should pull between 3 to 3.5...
  19. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    Unit is 6 years old heat exchanger is good and so...

    Unit is 6 years old heat exchanger is good and so is burner screen. Burner lite at incuder and burnt up all gaskets, gas valve was also bad. Pulled everything apart, replaced all gaskets, gas valve...
  20. Thread: Trane voyager

    by kms2579
    Replies
    27
    Views
    2,285

    Trane voyager

    Working on a Trane voyager that is backfiring out the air intake holes. Blower producing -2.50"wc an gas pressure at-.25"wc tech support thinks it a weak igniter which is brand new. Anyone seen this...
  21. With out seeing system just guessing that the...

    With out seeing system just guessing that the heating load is probably not big enough for the lowest firing rate of the boiler. Also radiant heat does not have a lot of water content, I would suggest...