  1. Replies
    19
    Views
    3,254

    I love the ones that say "The filter was dirty so...

    I love the ones that say "The filter was dirty so I turned it around to use the clean side." :rolleyes:
  2. Replies
    87
    Views
    4,993

    The answer to this question is very subjective...

    The answer to this question is very subjective and can't be answered accurately...only guessed.

    There will be more wear. How much? Don't know. Will the unit be sized properly? Will the od...
  3. Replies
    87
    Views
    4,993

    LOL :D Ya you right. I think my brains have...

    LOL :D

    Ya you right. I think my brains have turned to mush on this thread.

    I still maintain that there isn't enough info to know where to set the od stat. Just because the heat pump shows equal...
  4. Replies
    68
    Views
    4,746

    The 90% furnace may never pay for itself. If the...

    The 90% furnace may never pay for itself. If the system is designed right, the furnace will run only when absolutely needed. That may only be 20% of the time. Even though the furnace is more...
  5. Replies
    87
    Views
    4,993

    He is comparing apples to oranges. Suppose the...

    He is comparing apples to oranges.

    Suppose the furnace has 100,000 btu input which equates to 80,000btu output. At 16 degrees, the heat pump is putting out approx 21,200btus.

    A true comparison...
  6. Replies
    87
    Views
    4,993

    Information is what you make of it. I'm not...

    Information is what you make of it.

    I'm not flaming anyone. I am trying to help you understand that there is more to this than the limited information that you have. You have only performed one...
  7. Replies
    87
    Views
    4,993

    Yes, more efficient but costs more money out of...

    Yes, more efficient but costs more money out of your pocket to run. The HP has to run longer at lower temperatures and continuously if it isn't supplying enough BTUs. So, you are pumping more money...
  8. Replies
    87
    Views
    4,993

    Alrighty...Suppose you start your 20mpg car and...

    Alrighty...Suppose you start your 20mpg car and take off immediately knowing you have 2 flat tires. The car IS moving forward. Are you wasting Gas? The flat tires represent the temperature below...
  9. Replies
    87
    Views
    4,993

    Money is wasted because the power that you are...

    Money is wasted because the power that you are feeding into the condenser isn't supplying the required heat for the home. When your furnace eventually comes on, it has to make up for the drop in...
  10. Replies
    87
    Views
    4,993

    So, how many BTUs is your HP supplying at 16...

    So, how many BTUs is your HP supplying at 16 degrees? It may look like the HP is more efficient at this temperature but if it can't keep up with the heat loss of your home it will actually be more...
  11. Replies
    87
    Views
    4,993

    And this is why the cross-over setting should be...

    And this is why the cross-over setting should be plotted on a graph using information from a heat loss calculation. There would be no need to wait for the thermostat to drop 2 degrees (uncomfortable)...
  12. Replies
    87
    Views
    4,993

    Sheesh :rolleyes: Ok...How do you know you...

    Sheesh :rolleyes:

    Ok...How do you know you could "run the heat pump into the 20s" if you know nothing about the house or the equipment used? How do you know the heat pump would supply enough heat...
  13. Replies
    87
    Views
    4,993

    Where does your 20 degree setting come from?

    Where does your 20 degree setting come from?
  14. Replies
    87
    Views
    4,993

    Based on what?

    Based on what?
  15. Replies
    87
    Views
    4,993

    That doesn't matter. There is a point where your...

    That doesn't matter. There is a point where your HP will no longer keep up with the heat demand of the house. As the outdoor temperature drops, the heat pump heating Btus drop. Using your average...
  16. Replies
    87
    Views
    4,993

    The COP values comes from the manufacturers data....

    The COP values comes from the manufacturers data. An outdoor thermostat handles the switch-over to the gas furnace if your indoor thermostat doesn't have the capability to do so. However, a...
  17. Thread: S series

    by shodinjido
    Replies
    12
    Views
    841

    Sounds like you need a little thicker bridge to...

    Sounds like you need a little thicker bridge to keep all the cubes together until they hit the bin. Could be a problem with the harvest cycle as well staying on too long and melting the bridge.
  18. Replies
    19
    Views
    909

    Nah. He'll be back....We're the idiots afterall :D

    Nah. He'll be back....We're the idiots afterall :D
  19. Replies
    19
    Views
    909

    Assuming there was no heat loss calc performed,...

    Assuming there was no heat loss calc performed, how do you know that 4 tons is what this house needs. You don't even know where the house is located other than in Kentucky. In my area, this could be...
  20. Replies
    19
    Views
    909

    How do you know that 4 tons is right for that...

    How do you know that 4 tons is right for that particular house if you haven't seen the Manual J calc?
  21. Replies
    22
    Views
    9,207

    Yep..Volumetric Efficiency (VE) Internal...

    Yep..Volumetric Efficiency (VE)

    Internal combustion engines aren't 100% efficient.
  22. Replies
    26
    Views
    4,693

    http://www.acca.org/store/product.php?pid=213

    http://www.acca.org/store/product.php?pid=213
  23. Replies
    42
    Views
    4,426

    Interesting... I looked back to the...

    Interesting...

    I looked back to the installation manual dated 2001...Same thing applied back then...No Horizontal venting if not direct-vent.

    Oh well, as long as it gets fixed :rolleyes:
  24. Replies
    37
    Views
    2,885

    Nice looking install there. The P-trap for...

    Nice looking install there.

    The P-trap for your furnace is located behind the blower door and is factory installed. You humidifier doesn't need a P-trap.
  25. Replies
    42
    Views
    4,426

    Straight out of the Installation Guidelines: ...

    Straight out of the Installation Guidelines:

    IMPORTANT: When installed as a non-direct furnace, only vertical terminations are allowed. Do not use horizontal terminations when the furnace is...