Search:
Type: Posts; User: hockey
Search: Search took 0.02 seconds.
-
03-22-2012, 09:57 AM
- Replies
- 30
- Views
- 1,691
I own a school in MA. I am looking for an entry...
I own a school in MA. I am looking for an entry level Controls Class. ANy ideas?
hockey -
05-01-2010, 11:12 AM
Thread: Fix direct vent FP draft from outside?
by hockey- Replies
- 9
- Views
- 2,247
I have a basement fireplace... negative draft due...
I have a basement fireplace... negative draft due to 2nd and 3rd flue... oil furnace and ist flr fireplace cause negative pressure. It pulls the air DOWN the basement chimney. Do you know anyone in...
-
11-24-2009, 05:16 PM
Thread: Fireplace dimensions?
by hockey- Replies
- 5
- Views
- 1,061
Pellet Insert Manufacturer
Can anyone tell me who the manufacturer of this pellet insert is? Photos attached.
-
07-25-2009, 10:57 AM
Thread: pellet inserts
by hockey- Replies
- 5
- Views
- 1,357
I'm looking for a pellet stove insert that will...
I'm looking for a pellet stove insert that will fit in my basement fireplace. It's 20 1/2" tall and 28.75" wide (front opening). It's 21" deep. Can anyone recommend an insert that will fit in this...
-
07-25-2009, 10:38 AM
Thread: pellet insert
by hockey- Replies
- 6
- Views
- 2,374
Bob, was it the Englander 25EP? I am looking at...
Bob, was it the Englander 25EP? I am looking at the new 25EPI but they require an opening of ~36" wide and my fireplace is only ~26" wide. The drawing looks like it would still fit but Englander says...
-
07-15-2009, 09:25 PM
Thread: Pellet Stove install question -- Intake
by hockey- Replies
- 4
- Views
- 3,291
Makeup air
Yes, but the best way is to isolate the fireplace from the furnace. Burning outside air is better than burning conditioned air.
-
07-12-2009, 10:30 PM
Thread: Pellet Stove install question -- Intake
by hockey- Replies
- 4
- Views
- 3,291
I'm looking for a pellet stove insert for my...
I'm looking for a pellet stove insert for my basement. I MUST have outside air intake because my oil furnace will suck the smoke from my fireplace back into the room. My fireplace will also suck its...
-
02-23-2009, 07:32 PM
Thread: Oil Furnace Efficiency
by hockey- Replies
- 12
- Views
- 808
The efficiency of the burner is determined by O2%...
The efficiency of the burner is determined by O2% or CO2% and stack temperature. Overall efficiency must consider all the other stuff, but the burner efficiency is still a valid number.
-
02-23-2009, 07:16 PM
Thread: change nozzle size
by hockey- Replies
- 19
- Views
- 1,917
down firing vs Efficiency
You can install a smaller nozzle provided the stack temperature still exceeds 350 Deg F. Going from a .75 gph to a .60 gph is a fuel savings of 20%. The unit won't run any longer if the nozzle (heat...
-
02-16-2009, 10:07 PM
- Replies
- 3
- Views
- 1,746
Outdoor Reset Efficiency
The highest efficiency (lowest cost) is achieved by lowering the boiler temperatures (high and low) until it does not satisfy. The less propane you use, the more effificient it becomes. I have a...
-
09-12-2008, 08:48 AM
Thread: Starting New Company
by hockey- Replies
- 81
- Views
- 2,200
-
06-29-2008, 09:45 PM
Thread: Starting New Company
by hockey- Replies
- 81
- Views
- 2,200
-
05-30-2008, 10:23 AM
Thread: Comfort-Aire or Goodman
by hockey- Replies
- 28
- Views
- 2,385
Comfort-Aire Ductless Split
I am planning on buying and installing a Comfort-aire ductless split heat pump. Great deal $$$$$! Any opinions on quality?
-
04-15-2008, 06:12 AM
Thread: Starting New Company
by hockey- Replies
- 81
- Views
- 2,200
-
04-11-2008, 05:58 PM
Thread: Starting New Company
by hockey- Replies
- 81
- Views
- 2,200
-
12-18-2007, 10:42 PM
Thread: Oil burner question.
by hockey- Replies
- 17
- Views
- 1,502
Burner Box
Bill,
I'm not sure what box I have but it's red in color and it looks almost round/cylindrical. All corners are radiused, almost round 9-9.5" dia and 15-16" deep. can i cover with kaowool... -
12-18-2007, 04:23 PM
Thread: Oil burner question.
by hockey- Replies
- 17
- Views
- 1,502
Smith Cast iron Boiler
I have a Smith Cast Iron Boiler (Westfield, MA) with a Beckett Model SR burner. 'SR' doesn't show up anywhere on the Carlin chart you sent. My burner box is 9" wide x 9.5" deep x 15" tall. I think...
-
12-17-2007, 01:20 PM
Thread: Oil burner question.
by hockey- Replies
- 17
- Views
- 1,502
Very Old Boiler
Draft is good at -.04" and -.02" measured with Dwyer magnahelic. This boiler has always had low stack temp (350 degrees is acceptable, albeit at the low limit). I thought I said I went from hollow to...
-
12-15-2007, 10:23 PM
Thread: Oil burner question.
by hockey- Replies
- 17
- Views
- 1,502
Refractory Impingement
I have a Beckett gun that is cemented (non-removable) into the front of my hydronic boiler. (I assume it's a coal conversion)? During my tuneup today I noticed the flame is impinging on the rear...
-
11-03-2007, 05:05 PM
Thread: Trade Schools in MA
by hockey- Replies
- 6
- Views
- 1,347
School Advice
My advice is to choose the school with the quickest curriculum and job placement help. YOU WILL GET OUT OF ANY SCHOOL WHAT YOU PUT IN. Get working and learn the rest OTJ.
-
07-04-2007, 06:51 AM
Thread: Goodman Rooftop PHK024 High head pressure
by hockey- Replies
- 33
- Views
- 1,736
Metering devices
Thanks for the added info. A heat pump becomes more efficient as the difference between indoor and outdoor temperature gets smaller. I have a case where a rooftop heat pump is in a room where the ID...
-
07-03-2007, 09:26 PM
Thread: Goodman Rooftop PHK024 High head pressure
by hockey- Replies
- 33
- Views
- 1,736
School
Whoops! Sorry. We are a school. I am showing the students (and teachers) how a rooftop unit works. The room is 65 degrees. Surely that isn't too far out of heating spec.
-
07-03-2007, 08:09 PM
Thread: Goodman Rooftop PHK024 High head pressure
by hockey- Replies
- 33
- Views
- 1,736
2 metering devices
I cleaned both coils (ID coil had a little dust). We found that the Goodman has two flow-check piston metering devices. ONe is 047 DIa, the other is .061 dia. Does anyone know what size they are...
-
06-16-2007, 11:13 AM
Thread: Goodman Rooftop PHK024 High head pressure
by hockey- Replies
- 33
- Views
- 1,736
Airflow
You are correct: discharge is superheated so PT chart does not apply. I will check temperature drop/rise across indoor coil. It May be dirty!
-
06-15-2007, 08:27 PM
Thread: Goodman Rooftop PHK024 High head pressure
by hockey- Replies
- 33
- Views
- 1,736
Restriction?
We checked the metering device. MAYBE the drier is restricted...
Results 1 to 25 of 230

