  1. Trane BACnet RTU BCI-R Board Help.

    Yea I have that literature, it doesn't show the bacnet connections.521271
  2. Trane BACnet RTU BCI-R Board Help.

    Looking for some help with bacnet mstp wiring regarding the Trane BACnet RTU BCI-R Board. In the literature it doesn't really explain which terminals are for the comm wire. I included a photo of the...
  3. JCI FX30 Help!! "loading lexicon list" Stall

    Im trying to connect to a new FX30. Ive loaded the updates into the 30 via work bench and im able to connect to the 30 with my laptop but when using the customers older laptop the FX30 starts to boot...
  4. Norlake CB0751C-A Walk-in Half Evap Frosting?

    Working on a Norlake CB0751C-A Walk-in and while the system is running only half the evaporator is frosting up. It's a TXV R22 style system, I've weighted in the correct charge and checked superheat....
  5. Replies
    14
    Views
    627

    I'm union so the hiring process is a little...

    I'm union so the hiring process is a little different.
  6. Replies
    14
    Views
    627

    Idk where you stand with schooling and training...

    Idk where you stand with schooling and training but Local 777 out of Meriden CT how's a really good apprentice program.
  7. Replies
    14
    Views
    627

    Yea I'm in RI and trane is a union only shop here...

    Yea I'm in RI and trane is a union only shop here also the same in Boston but your rite the CT branch is non-union.
  8. Replies
    14
    Views
    627

    I worked for trane for 4 years, it all depends on...

    I worked for trane for 4 years, it all depends on your skill set. Some guys at trane work on RTUs, AHUs, Fan Coils, exc. other guys like myself work on only chillers.
  9. Replies
    14
    Views
    627

    Some Trane branches union shops, so transferring...

    Some Trane branches union shops, so transferring could get tricky.
  10. Replies
    18
    Views
    1,304

    Non condensables possibly?

    Non condensables possibly?
  11. Replies
    17
    Views
    830

    Is it a glycol system?

    Is it a glycol system?
  12. Replies
    29
    Views
    1,473

    Controls Cabinet Laptop Stand.

    I've seen a lot of guys in the field make their own custom cabinet laptop holders. Just wondering what's out there and if anyone has any advice on where to buy one or how to make one? Thanks
  13. Installing AC with a two zone gas furnace.

    Looked at a small job last night, 80k BTU gas furnace with 2 zones and honeywell zone dampers and a 3 ton coil in place. Are there any precautions with air flow and zone dampers for central air?
  14. Replies
    15
    Views
    799

    You don't need any type of converters, if the...

    You don't need any type of converters, if the chillers have a ccn card you connect between that and the standard RS-485 on the jace. What you will need to purchase is the ccn license for your local...
  15. Replies
    28
    Views
    1,439

    Buy a system online and install it but don't call...

    Buy a system online and install it but don't call us looking for help.
  16. Replies
    1
    Views
    321

    KMC Controls?

    Has anyone had any experience with KMC controls? I mainly do JCI but the company I work for is trying to pick up a new school district with KMC controls. Is the system propriety? The schools have...
  17. Replies
    4
    Views
    277

    What about in hand? I've tried running it through...

    What about in hand? I've tried running it through in hand mode and I'm still not getting any lights.
  18. Replies
    4
    Views
    277

    Siemens/Powers issue

    I'm working on a older Siemens/Powers system and I'm having an issue with the analog output module. I've included some photos, should the AO module alway be lit up?500521500531
  19. Replies
    15
    Views
    799

    Last summer I brought on two carrier screw...

    Last summer I brought on two carrier screw chiller onto a FX70. It was pretty straight forward, just purchased the proper CCN license for the FX70 and wired into the RS485. Once everything was all...
  20. Replies
    5
    Views
    390

    Might be worth trying to slim up the DMO file and...

    Might be worth trying to slim up the DMO file and only import the points your going to use.
  21. Replies
    45
    Views
    4,618

    Well I guess that's just a personal preference....

    Well I guess that's just a personal preference. I've never experienced anything like that with propress, as long as it's been properly preped and fitted. The company I work for did a 20 million...
  22. Replies
    45
    Views
    4,618

    What's wrong with the propress and zone valves?

    What's wrong with the propress and zone valves?
  23. Advice on easy to set up small BAS system

    There's a lot of programing going on here, definitely not a good project to get your feet wet on. A good place to start would be to sit down and generate a points list for each piece of equipment....
  24. Replies
    45
    Views
    4,618

    I've used the the navien header beside, not...

    I've used the the navien header beside, not really a fan of it plus it didn't really fit this application.
  25. Replies
    45
    Views
    4,618

    Yea here's the finished product. 470341