Search:

Type: Posts; User: amigo

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    3
    Views
    131

    Thank you. I was told that it also depends on...

    Thank you. I was told that it also depends on version of DHMI, like if it was version 3.40, then I would need orcaview 3.40. Is possible for you to send me 3.40 iso image or a download link?
  2. Replies
    12
    Views
    369

    Thanks for the details. I think I have now a...

    Thanks for the details.
    I think I have now a clearer understanding of what is gotta happen.
    cheers.
  3. Replies
    3
    Views
    131

    Delta Controls DHMI-7E

    What is needed to program this touch screen? Can I do it with Orcaview 3.33 and DEW key?
  4. Replies
    12
    Views
    369

    I am in the process of suggesting an upgrade for...

    I am in the process of suggesting an upgrade for such an exact system (e-bus and c-bus combo), and was gonna do away with zone managers and just bring in the xl-10 devices, get rid of the c-bus...
  5. Replies
    2
    Views
    196

    Thank you, I get what you are saying but I was...

    Thank you, I get what you are saying but I was really hoping not to have to recreate points.
    But seems like there is no easy way out.
  6. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    397

    did not know z-wave has two frequencies, good to...

    did not know z-wave has two frequencies, good to know, thanks.

    From what I hear RCS themostat is one of the better ones, may be you can ask them if they make an EU version.
  7. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    397

    I suggest you ask Fibaro what they suggest to be...

    I suggest you ask Fibaro what they suggest to be a solid thermostat for their system.
    I am not familiar with Z-Wave much, but google brings up this thread:...
  8. Replies
    2
    Views
    196

    Delta Illustrator question

    First time messing with Delta graphics, Oracview 3.33
    I am trying to bring some third party bacnet points into the graphics, but can't figure how to easily make active/inactive into on/off. I have a...
  9. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    397

    You have misunderstood what that particular...

    You have misunderstood what that particular router you bought does. It does not convert BACnet to IP, it converts BACnet serial to BACnet/IP, but it still will only understand BACnet. Since Fibaro...
  10. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    397

    Can Fibaro talk BACnet?

    Can Fibaro talk BACnet?
  11. Replies
    5
    Views
    377

    like Scroo said, as far as I know Trane BCU could...

    like Scroo said, as far as I know Trane BCU could never talk BACnet MSTP. Double check that it is a Trane BCU or something else.
  12. Replies
    13
    Views
    282

    I see that /prism/resources is ENT related. And...

    I see that /prism/resources is ENT related. And how do I reset the counters?
    I think my issue is down stream of UNC, is there a similar command for UNC resources?
    Just be clear, I am in browser...
  13. Replies
    13
    Views
    282

    Site is very remote and presently I only have...

    Site is very remote and presently I only have browser access. Also, can not get into ENT remotely and can not access Admin tool because PC is locked down from remote access.
    I will try...
  14. Replies
    13
    Views
    282

    thx. I can do a system/eventLog via browser...

    thx.
    I can do a system/eventLog via browser session, and not much in there as far as errors, just says that jace rebooted (when I did it on site) and has battery test fail message, some other minor...
  15. Replies
    13
    Views
    282

    how do I get the error log via browser session?

    how do I get the error log via browser session?
  16. Replies
    13
    Views
    282

    one 1000, and about 29 mstp devices on its trunk....

    one 1000, and about 29 mstp devices on its trunk.
    I thought it may be an mstp issue, but I can't explain why a reboot of unc fixes it temporarily. So I tend to rule out an mstp issue.
    The system...
  17. Replies
    13
    Views
    282

    No, have not. What my issue is it seems after a...

    No, have not.
    What my issue is it seems after a couple days from a reboot, UNC seems to stop talking bacnet/ip to mnb-1000 and all the controllers that sit on the mnb-1000s mstp bus.
    Reboot seems...
  18. Replies
    13
    Views
    282

    I am pretty well at last resort, :) hoping there...

    I am pretty well at last resort, :)
    hoping there are such commands for R2 but not sure myself.
  19. Replies
    13
    Views
    282

    TAC UNC-520 reset through browser session

    Is there anyway to reset/restart a UNC-520 through the browser session?
    The UNC (R2 Jace) is hanging up quite often now, and as temporary band-aid I like to be able to remotely reset it/restart the...
  20. red lion is normally very good at tech support,...

    red lion is normally very good at tech support, so I suggest you get in touch with them direct.
    although I have never brought a red lion into mstp, I have messed around with crimson software to know...
  21. I have done your exact setup many times, so I can...

    I have done your exact setup many times, so I can certainly tell you that it works.
    go to envision system properties and make sure all is setup correctly there, bacnet/ip vs bacent/eth, etc.
  22. I assume this is not an Alerton router, if it is...

    I assume this is not an Alerton router, if it is then kontrol is right.
    If it is not then you configure your router how you have to.
    Either case, programming controllers through a router with...
  23. Replies
    4
    Views
    316

    thx, will report back if I end up using it.

    thx,
    will report back if I end up using it.
  24. Replies
    4
    Views
    316

    Thx I guess not many people have used it, I'll...

    Thx
    I guess not many people have used it, I'll see if I am brave enough to be at the bleeding edge.
  25. Replies
    4
    Views
    316

    BABEL BUSTER IP/XL

    Anyone use one of these?
    http://www.csimn.com/CSI_pages/BBIPXL.html

    does it support NCI variables?

    Thanks.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event