Search:

Type: Posts; User: Theluckyloser

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. service technicians wanted.Westchester NY/Lower CT

    Residential techs with at least 4 yrs exp.for growing company.We are in White Plains NY.Able to work alone.A/C and gas heat furnaces and boilers
    Respond to this thread.Steve
  2. Replies
    1
    Views
    274

    Trane Air Handler short

    I have a low voltage short in a Trane air handler GAM5AOC48M41SAA.
    When I jump R to w1 w2 or w3 transformer draws 13 amps.short inside AH because all field wiring taken off terminal strip for...
  3. Replies
    5
    Views
    458

    I should have added we are strictly residential

    I should have added we are strictly residential
  4. Replies
    5
    Views
    458

    Westchester NY techs wanted

    Experienced techs wanted for a large westchester based hvac company. Minimum 3 years experiences. Must be familiar with gas furnaces & boilers, steam, some oil & all air conditioning. Lookin to fill...
  5. Replies
    0
    Views
    153

    Westchester NY techs wanted

    Experienced techs wanted for a large westchester based hvac com
  6. Replies
    14
    Views
    1,170

    hvacvegas says "stay away from spacepaks. You'll...

    hvacvegas says "stay away from spacepaks. You'll never make money,"What/
    My company makes 3-4 million sales yearly high velocity.
    Flip67-Static pressures are higher around 1.5"wc
  7. Replies
    1
    Views
    488

    Thru the wall condensers

    The aero-sys thru wall units ive come across in the city all have hi Head pressures.Started one Saturday and opened the valves, and had almost 500 head(R410a)That one I believe was 48,000Btu.
    ...
  8. Replies
    3
    Views
    1,866

    Thanks JDH.

    Thanks JDH.
  9. Replies
    3
    Views
    1,866

    Comfort-Aire manuals

    I will be installing 3 Comfort-aire geomax 2.Does anyone have install manuals
    that I can access online.ComfortAire / Heatcontrollers website just has basic customer brochures.

    HTV024A1CO1JRK and...
  10. N.Y.Weschester /Lower CT Junior tech wanted

    We will be hiring a junior Tech next month.Some training or experience is
    good,but really looking for strong character,hard workers.We will train you.
    Need refrigerant license,and good driving...
  11. Replies
    23
    Views
    2,463

    Do you leave the hose assembly attached? ...

    Do you leave the hose assembly attached?


    That may be my problem Davidr.Ill order the o2 sensor but $140 seems like alot.
  12. Replies
    23
    Views
    2,463

    I t may be me,but this is my second one, and I...

    I t may be me,but this is my second one, and I was very careful to keep moisture out of the cup and take care of it,since it cost over $800. with the printer.It does sit in a cold van here in NY,and...
  13. Replies
    23
    Views
    2,463

    down again

    My NEW Fyrite Tech 60 is down now.Only 5 months old and now I need an O2 Sensor that cost $140.00.These Fyrite Comb.Analyzers are GARBAGE!!!!
  14. Replies
    17
    Views
    2,103

    xc15 condenser

    How would you like to change compressor on this condenser
  15. Replies
    31
    Views
    2,741

    Nice piping.How are the boilers wired together,I...

    Nice piping.How are the boilers wired together,I know they are modcons.Do they fire together or depends on outdoor temp?
  16. Replies
    8
    Views
    1,287

    Got Furnace Cement??

    No reducers for a flue?
    No Tee to run HW heater?
    No problem.
    Get the furnace cement!!!
  17. Thread: test pic

    by Theluckyloser
    Replies
    0
    Views
    246

    test pic

    african cichlids
  18. Replies
    5
    Views
    1,639

    At 11 seconds that was normal reversing valve,but...

    At 11 seconds that was normal reversing valve,but at 45 seconds that compressor is loud!!
  19. Lennox Pulse,and CompleteHeat.CompleteHeat not a...

    Lennox Pulse,and CompleteHeat.CompleteHeat not a furnace but they are nightmare
  20. I took the Certification class,and worked on...

    I took the Certification class,and worked on one.They seem to be nice.Can direct vent or chimney vent.Fires blue flame,High pressure for better atomization.I havent installed one yet,but I like...
  21. Replies
    3
    Views
    746

    There is also Unico Hi velocity,very good..We...

    There is also Unico Hi velocity,very good..We install hundreds of Spacepaks and unico every year.Both are good, never heard of lines deteriorating.Compared to conventional systems,they are...
  22. Replies
    1
    Views
    522

    westchester NY entry level

    NEED DEPENDABLE TECH 1 YEAR EXPERIENCE FOR FAST GROWING CO.,FOR MAINTENANCE ON RESIDENTIAL A/C AND HEAT.WILL TRAIN ,MEDICAL,401K,UNIFORMS,TRUCK,GPS,ETC .WILLING TO GO ON CALL EVERY 3RD WEEK...
  23. Replies
    23
    Views
    2,463

    bacharach comb analyzer

    I had my Fyrite Tech 60 serviced in December 2007,calibrated.O2 sensor not reading again.Have only used 4 times since caibration.I think its the second one replaced,and co sensor also, in three year...
  24. Replies
    3
    Views
    2,284

    carrier rooftop condenser

    38AE014500 made in 1986.What is the tonnage.Where can I find a schematic online?