    Geothermal anyone

    See 265 psi on discharge pressure is telling me R-22 If that is the case i would agree with you but some more measurments need to be taken. Put a temp. probe on the out let of the evaporator i know...
  2. Replies
    1
    Views
    383

    heatpump sizing

    who ever seen a 5 ton h/p with a 4 ton a/h anyone?
  3. Replies
    17
    Views
    2,401

    From My research you have only until Dec. 2009 to...

    From My research you have only until Dec. 2009 to place a claim, Trane will not pay any labor or drive time. Trane will only replace part.

    Authorized material:
    kit02590-250 MBH( motor and...
  4. Replies
    17
    Views
    2,401

    1. Disconnect power from unit. 2. Pull the...

    1. Disconnect power from unit.

    2. Pull the orange and black motor leads from the ignition control and isolate leads.

    3. Reapply power to unit.

    4. If combustion motor still runs, replace...
  5. Replies
    25
    Views
    6,079

    good discussion

    jab490

    If your loop is undersized of course your system is going to run un-efficiently. poor water flow in the summer months running a/c will over heat the compressor heating the windings in the...
  6. Replies
    32
    Views
    3,677

    OH my god i hope that was a sears install and not...

    OH my god i hope that was a sears install and not an actual carrier dealer.thats insulting:eek:
  7. Replies
    18
    Views
    2,098

    How long do you think that guy will be working

    How long do you think that guy will be working
  8. Replies
    12
    Views
    1,445

    look at that

    Talking about some one that is to concerned with safty of equipment or others:mad::mad:
  9. Replies
    25
    Views
    6,417

    WOW is right

    he has no idea how much energy is being wasted to heat that water for his water heater how funnny is that.

    some people just dont get it
  10. Replies
    25
    Views
    6,079

    things to think about with open loop systems

    I have been installing and servicing geothermal now for about three years. the company i work for is the biggest geothermal installers in central PA
    A few questions i must ask:

    Why are you going...
  11. all of my power tools are hitachi. they are not...

    all of my power tools are hitachi. they are not as good as a dewalt but for the price between them and the proformans i have recieved from the hitachi go with it you will enjoy it. i have the 14...
  12. Replies
    1
    Views
    581

    looking for a good anemometer

    any suggestions on a anemometer? how many of you techs carry one?
  13. Replies
    22
    Views
    1,410

    the reason i ask is because mold needs moisture...

    the reason i ask is because mold needs moisture ,darkness and material to grow on. the only things you can really control is moisture and darkness. control them and you will control your problem.
  14. Replies
    22
    Views
    1,410

    how is your lighting situtation? is there many...

    how is your lighting situtation? is there many trees? how much light is influenced into the cottage?
  15. Replies
    16
    Views
    1,136

    thanks for all the tips! i talked with tech...

    thanks for all the tips! i talked with tech support today from carrier and they also are leaning towards the metering device. thanks again if there is any one that can help me become a pro. member...
  16. Replies
    16
    Views
    1,136

    i have appllied a few times and never got the...

    i have appllied a few times and never got the privledge approved. sent in my epa # rses membership # nate certificate the schooling i attened and never got the pass through to pro.
  17. Replies
    16
    Views
    1,136

    that was one of my approachs but negative...

    that was one of my approachs
    but negative piston is in correctly.
  18. Replies
    16
    Views
    1,136

    i am thinking bad compressor

    Payne residential split system 2 ton a/c w/gas heat
    condensor
    mn:pa10ja024-g
    sn:4005x28450
    suction-82psig
    discharge-140psig
    suction temp.-50 degree/0 degree super heat
    discharge-78 degree/2...
  19. Replies
    5
    Views
    495

    air flow is as good as it getts for that unit i...

    air flow is as good as it getts for that unit i cleaned the evap coil changed the filters made sure fan was running up to speed.
    i almost think that the compressor isnt pumping the capacity that it...
  20. Replies
    5
    Views
    495

    compressor discharge temp. low

    today i was on a old york roof top unit (HP), no data info all i know is the building is 30 years old and the equipment looks to be close to the same age. but not sure. any way it was 92 degree...
  21. Replies
    14
    Views
    1,179

    yea i tried heating mode and the pressures just...

    yea i tried heating mode and the pressures just got worse and yes i changed my hoses
  22. Replies
    14
    Views
    1,179

    sam the man can the indoor metering device is a...

    sam the man can the indoor metering device is a piston. could that still overfeed the coil?
  23. Replies
    14
    Views
    1,179

    yea that is what i am afraid of so all the info...

    yea that is what i am afraid of so all the info i can get will be appreciated
  24. Replies
    14
    Views
    1,179

    yeah i checked for the bleeding reversing valve...

    yeah i checked for the bleeding reversing valve and i i had no diff. i am pretty sure that means it is good.
  25. Replies
    14
    Views
    1,179

    high suction pressure

    today i was on a lennox 10hpb24-3p split system (Heat Pump) i had 9 degree delta T
    suction pressure 110 psi
    head pressure 145 psi
    2 degree subcooling and 2 degree superheat
    ambient temp. was...