  1. Carrier Infinity with LFP Humidiifier

    our old 80% furnace had an old aprilaire 110, does the LFP do a comparable amount of humidification as the 110? We never had the infinity control on the old furnace so I'm not sure what kind of...
  2. Hi, We had an infinity system installed this...

    Hi,

    We had an infinity system installed this summer and are now using the LFP Large Fan Powered Humidifier.

    Per the directions, I went into advanced and then into checkout/humidifier/on-off and...
  3. Replies
    14
    Views
    1,542

    ECM Noise

    I called the shop today, and he said not a problem they would send a carrier technician out and check it out.

    He also said they would make sure it's ready for winter.
    (although it's pretty hot...
  4. Replies
    14
    Views
    1,542

    ecm motor

    AO-Smith comes to mind... for the little ECM

    Is this common for them to squeak, some of you must install these quite a bit, hopefully it can be adjusted so they don't need to tear it all apart.
    ...
  5. Replies
    14
    Views
    1,542

    Plain spoken

    That's what I needed to hear.

    I will get him back here - or somebody from his shop that is familiar w/these to make the adjustment.
  6. Replies
    24
    Views
    4,323

    It's not he DIY is an expert, I believe it was a...

    It's not he DIY is an expert, I believe it was a case of somebody else doing it. Moreso - living and learning.

    Pictures tell a thousand words - even to an expert (I would think)
  7. Replies
    14
    Views
    1,542

    Still squeaking

    Well, the install is complete as of today. The installer did look at it and noticed it squeaking, almost seams as if the little louvers on the fan rub... Anyway he said we can wait and see what...
  8. Replies
    24
    Views
    4,323

    York photos and descriptions A+

    York has been very helpful for what to look out for in my infinity installation. His explanations are honest even if they're not all fluffy. As a consumer, these pictures and his detail text are of...
  9. Replies
    14
    Views
    1,542

    Hi, Our furnace and new ductwork is complete! ...

    Hi,

    Our furnace and new ductwork is complete! The furnace is the MVB-080, AC - 24ANA7-36, Inifnity control and LFP Humidifier.

    This system purrs whisper quiet, that is until I was down in the...
  10. Replies
    5
    Views
    665

    perel, It was built in '92. 1890 sf ranch,...

    perel,

    It was built in '92.

    1890 sf ranch, 2x6 outside walls, cheap crestline casement windows.

    It's not a real leaky house but it's not a super tight house either, has older cedar siding...
  11. ARI NUMBER

    If I found my ARI number for our furnace that's presently being installed.

    (equipment is all carrier - 24ana736 condenser/CNPV3621 Coil/MVB080-14 furnace...

    "874090 CARRIER AIR CONDITIONING ...
  12. Replies
    5
    Views
    665

    In the process of having a new Infinity system...

    In the process of having a new Infinity system installed, and saw the Ventilator for the outside air intake.

    Is this worth it, is it a tricky install. Our Joist spaces are about full! Not sure...
  13. Replies
    13
    Views
    1,543

    Bertrand, I just had the new 2006 version...

    Bertrand, I just had the new 2006 version (24ANA7) of the 38TDB036 installed and I can tell you it is WHISPER QUIET! My neighbor has a carrier 3 ton unit and it is so loud that I can hear there unit...
  14. duct sealing

    The duct seal I put on, he doesn't want to do it. He said it makes little difference... I told him the with a variable speed furnace it's supposed to make a difference (he said why? and I said...
  15. Hi York The F100 was not in stock, the F150...

    Hi York
    The F100 was not in stock, the F150 takes the samemedia as the 100, the 150 was the same cost. The turning vanes are there - here's a few pictures - the tac welds are somewhat hard to see...
  16. filter drier

    On the inside, here is a better view, also the gas line was done today. Although no ductwork today : (( probably because they worked Saturday and I was so greatful he gave us AC back, I told him I...
  17. Install Progress

    The gas line got done today, hopefully they HVAC guy will get out there today and work on the return and PVC, I won't know until I get home from work. He said "Monday or Tuesday" - I'm not in that...
  18. Here are some pictures of our install progress,...

    Here are some pictures of our install progress, They got the new ductwork in our mechanical room and got the AC up and running (and it's a good thing because it was hot!)

    Monday they will be back...
  19. Our Infinity system was installed today and...

    Our Infinity system was installed today and hooked up, although the job isn't complete it's operational. For the last couple days the outside air temp has been about 90 degrees.

    The install is...
  20. Hi, The new system being put in our house is the...

    Hi, The new system being put in our house is the infinity.

    There is a cased N coil and then sheetmetal plenum. Is it best to mount the N-Coil to the side of the plenum or the front (facing the...
  21. Media Cabinet

    The FilCab that came with the new MVB080 is a 20", the installation says that the cabinet can be used for 4 tons as well... The guide says that the 4" block/stop be used for units smaller than 4...
  22. honeywell cabinet

    Because it's 20" tall and the MVB-080 (blower compartment) is only 16"

    The Return drop will elbow directly into the cab, the cab will be mounted directly to the side of the furnace. I realize the...
  23. Hi which of these cabinets will work best with...

    Hi which of these cabinets will work best with the infinity control? I believe there is some indication of needing cleaning with the system (built in the Infinity control...)

    The Honeywell...
  24. F100

    York

    You're awesome!

    The f100 or f200 is what he originally suggested to use w/the trane (I was considering before the Infinity)

    Hopefully he can get one quick

    Thank you
  25. media cabinet for mvb080

    The MVB080 is less than 4 ton, I see the illustration on the block plate. I guess my filters will then be 20x25 when the 16x25 would be the ideal cabinet.