  1. Thread: Recent install

    by RACMT
    Replies
    19
    Views
    1,943

    You use C Vent for natural draft hot water tanks,...

    You use C Vent for natural draft hot water tanks, C Vent is Galvanized single wall with 6 inch clearance to comb, that goes into the B Vent which is aluminum inside and galvanized outside with an air...
  2. Replies
    59
    Views
    5,811

    You guys are being snide. At least he is trying....

    You guys are being snide. At least he is trying. You guys are blessed, you are more refined and have the opportunity to work for big companys or are successful owners that are able to have nice...
  3. Replies
    59
    Views
    5,811

    Its all good man. You will learn quick enough...

    Its all good man. You will learn quick enough that everyone has their own nit pick.. At least you have the courage to put your pictures up on the WOP. Props for that. Some people lack in their...
  4. Thread: VS Blower Noise

    by RACMT
    Replies
    8
    Views
    658

    Is the blower wheel dirty and a bit off balanced.

    Is the blower wheel dirty and a bit off balanced.
  5. Replies
    1
    Views
    191

    Anyone here from Winnipeg, MB?

    I'm moving this summer to Winnipeg, I need some advice on where to buy a good house for a family of four near a good elementary school. My budget for a house is $180,000 max.

    Thanks.
  6. Thread: Electrical help

    by RACMT
    Replies
    37
    Views
    3,819

    I love you guys.

    I love you guys.
  7. Replies
    49
    Views
    5,534

    He's asking about Nylog not Thread lock.. Nylog...

    He's asking about Nylog not Thread lock.. Nylog mixes with the oil in the system fine. It is made to use with the system. There is Blue and Red.

    There is no movement on the mating edge of the...
  8. Some one said it was a scroll.. They dont always...

    Some one said it was a scroll.. They dont always need CCH but up here we put them on because they always start with liquid in them without it. On the scrolls the wear and tear causes vibration and it...
  9. Just don't mount them directly on the ground....

    Just don't mount them directly on the ground. When I heard under a deck I was not picturing that.. That is actually pretty decent.
  10. Replies
    6
    Views
    1,284

    lol

    lol
  11. Replies
    49
    Views
    11,193

    First Step is accepting that you made a mistake...

    First Step is accepting that you made a mistake lol..

    We have all done stupid crap that coulda got someone killed but on the Friday at 7pm and you are still working when it is boiling outside and...
  12. Replies
    19
    Views
    2,138

    This is kinda like debating religion... The way I...

    This is kinda like debating religion... The way I see it is if the glove fits scenario. If the NG is Cheap and readily available in your area then boom. If there is no NG in your area and it is...
  13. Replies
    13
    Views
    862

    I wonder if he could trend the OAT and pair it...

    I wonder if he could trend the OAT and pair it with the run time of the HP and see what the exact OAT was when the Stat called, Could either be a faulty sensor or the stat like you said.
  14. Replies
    15
    Views
    1,012

    Let me know what you decide to do and how it...

    Let me know what you decide to do and how it works out for you. Good Luck!
  15. I cant tell you that you may be getting liquid in...

    I cant tell you that you may be getting liquid in the compressor and that the crank case heater may be faulty... Get this fixed before you break a rod or shatter a piston.
  16. Replies
    13
    Views
    862

    Are you sure it wasn't in Defrost Mode? It was...

    Are you sure it wasn't in Defrost Mode? It was -9F out, that could of triggered a DFC.
  17. Replies
    15
    Views
    1,012

    I'm dealing with one building right now that the...

    I'm dealing with one building right now that the two units failed in the building and caused $150,000 in water damage.. I see it all the time.
  18. Thread: A new project

    by RACMT
    Replies
    7
    Views
    1,292

    :weird: Who put you up to this?

    :weird: Who put you up to this?
  19. Replies
    15
    Views
    1,012

    http://www.floodmaster.com/products/hvac-condensat...

    http://www.floodmaster.com/products/hvac-condensate-overflow-alarm.php
  20. Replies
    15
    Views
    1,012

    You can wire the overflow switch to a buzzer or a...

    You can wire the overflow switch to a buzzer or a light that you can have in you living space. As long as you can hear it or see it to rectify the problem immediately. By cutting the heat, I would...
  21. Replies
    22
    Views
    2,903

    I have three others that have more switches and...

    I have three others that have more switches and fuses but its late...
  22. Replies
    22
    Views
    2,903

    As Requested: 557471 :cheers:

    As Requested: 557471 :cheers:
  23. Thread: Errrrr

    by RACMT
    Replies
    27
    Views
    2,509

    Three apprentices 80 man hours and taking it a...

    Three apprentices 80 man hours and taking it a part piece by piece?!?!?! LMFAO :anyone: It was probably a flat roof converted to a gable roof over the years. Sadly when roofs leak or get to the point...
  24. Replies
    15
    Views
    1,012

    The Condensate that comes off your A/C coil and...

    The Condensate that comes off your A/C coil and DHU Coil is just water that condensed out of the air that you breath, this is not corrosive.

    The condensate that comes from you Natural Gas furnace...
  25. Replies
    41
    Views
    4,896

    Fair enough, what do you work on?

    Fair enough, what do you work on?
  26. Thread: Electrical help

    by RACMT
    Replies
    37
    Views
    3,819

    I didn't mean to hit the dislike button my mouse...

    I didn't mean to hit the dislike button my mouse was on it and I clicked by accident.

    There is no better way to learn than putting your meter to everything and getting to know systems yourself....
  27. Replies
    41
    Views
    4,896

    What do you work on? I use 1/4 all the time on...

    What do you work on? I use 1/4 all the time on resi there is no point to pull out huge vac lines on 2 ton unit with 15 feet of lineset.. I only pull the big stuff out when I work on 5+ ton equipment....
  28. Replies
    41
    Views
    4,896

    Any thing is possible but::::>...

    Any thing is possible but::::> http://yellowjacket.com/product/superevac-evacuation-manifolds/ or http://yellowjacket.com/product/superevac-evacuation-systems-i-ii-iii/
  29. Replies
    12
    Views
    3,567

    I bet it was broken...

    I bet it was broken...
  30. Thread: Common confusion

    by RACMT
    Replies
    10
    Views
    675

    There's some good info here.

    There's some good info here.
  31. Replies
    22
    Views
    2,903

    Ya that's pretty common where I'm at too.

    Ya that's pretty common where I'm at too.
  32. Thread: Common confusion

    by RACMT
    Replies
    10
    Views
    675

    It's the "common" input/output to the switch. The...

    It's the "common" input/output to the switch. The "NO" or normally open terminal is disconnected from COM when the switch is inactive, and connected when the switch is active. The "NC" or...
  33. Replies
    3
    Views
    360

    Check your flue pipe and air inlet, some times...

    Check your flue pipe and air inlet, some times they get ice or snow build up. Or on windy days the wind ducks with the roll out switch and after three attempts it locks the unit out.
  34. Replies
    15
    Views
    4,088

    Man, They paid extra for those racing stripes......

    Man, They paid extra for those racing stripes...

    ::DD:
  35. Thread: Ductless Mini

    by RACMT
    Replies
    9
    Views
    1,253

    It all comes down to your wallet really... Pay...

    It all comes down to your wallet really... Pay little up front and pay for the headaches and energy bills later. Pay a lot up front on good quality units and you will have less headaches in the long...
  36. Thread: Ductless Mini

    by RACMT
    Replies
    9
    Views
    1,253

    Just remember as one goes up the other goes down....

    Just remember as one goes up the other goes down. The colder the out door ambient temperature gets the less heat the system can absorb from outside, so the unit will have to run longer cycles to...
  37. Thread: Errrrr

    by RACMT
    Replies
    27
    Views
    2,509

    That's the hole point of this thread lol

    That's the hole point of this thread lol
  38. Thread: Errrrr

    by RACMT
    Replies
    27
    Views
    2,509

    A PTAC is a Packaged Terminal Air Conditioner...

    A PTAC is a Packaged Terminal Air Conditioner that is used in hotels and is installed through a hole in the wall.

    A Gas Pack or Gas Packaged unit with A/C is used on Roof Tops or Ground Mounts....
  39. Thread: Cold weather

    by RACMT
    Replies
    37
    Views
    2,484

    Sorry for the spelling mistakes, to angry to here...

    Sorry for the spelling mistakes, to angry to here people are living in 69F temps right now when my TStat is set to 69F and the furnace has been running for the last 25 min to maintain set point....
  40. Thread: Cold weather

    by RACMT
    Replies
    37
    Views
    2,484

    I live up in Norther Ontario Canada. It has been...

    I live up in Norther Ontario Canada. It has been -25 for the last three weeks. Couple years back it got up to -47F, My block heater in my car wouldnt work, my coolant was slush, my oil was guck and...
  41. Replies
    15
    Views
    1,497

    Yes.

    Yes.
  42. Go over to your Thermostat and switch the Fan...

    Go over to your Thermostat and switch the Fan button from On to Auto. If the fan button is turned on the fan will run continuously even when the furnace isn't firing. Auto turns the fan on only when...
  43. Replies
    4
    Views
    521

    And that is adjustable down Spout to get the...

    And that is adjustable down Spout to get the water away from your foundation... Multipurpose I guess..
  44. Replies
    22
    Views
    2,903

    I have a few boxes with extension cord with an on...

    I have a few boxes with extension cord with an on off toggle and a start run spring toggle with a fuse. I just pull off the potential or current relay and alligator clamp on my S R and C then plug...
  45. Thread: Errrrr

    by RACMT
    Replies
    27
    Views
    2,509

    :nopity: When you say gas pack do you mean RTU...

    :nopity: When you say gas pack do you mean RTU Gas Pack or a Gas Furnace?
  46. Thread: Artic Mechanical

    by RACMT
    Replies
    8
    Views
    1,294

    Ya they do, I didnt really look at the number..

    Ya they do, I didnt really look at the number..
  47. Replies
    6
    Views
    520

    Are there no balancing dampers on the branch...

    Are there no balancing dampers on the branch lines just off the trunk line that you could play with to help isolate where you need more or less air. That would be the simple solution. If there aren't...
  48. Replies
    34
    Views
    4,410

    GET ''R'' DONE the Boss Said Loudly over the...

    GET ''R'' DONE the Boss Said Loudly over the radio...
  49. Thread: HRV question

    by RACMT
    Replies
    3
    Views
    324

    If you want to double check then get a probe...

    If you want to double check then get a probe thermometer and take a temperature reading while your HRV is off and you furnace fan is on see if it is drawing any air..
  50. Thread: HRV question

    by RACMT
    Replies
    3
    Views
    324

    Depending on your make and model of HRV, there...

    Depending on your make and model of HRV, there may be a back draft damper on your HRV to reduce this from happening.
Results 1 to 50 of 759
Page 1 of 16 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards