    Mal is now Richard Castle. He makes reference to...

    Mal is now Richard Castle. He makes reference to Firefly from time to time on Castle.
  2. Replies
    37
    Views
    1,347

    If his only ground is a gas line, there could be...

    If his only ground is a gas line, there could be stray ghost voltage coming from it, being induced by power lines wrapped around or run along side it. A gas line is not a proper ground.
  3. Replies
    37
    Views
    1,347

    Gas valve solenoid might be shorting to gas line?...

    Gas valve solenoid might be shorting to gas line?
    Could be a coincidence.
    Poor ground.
    Had a Lennox a while back that was grounded only to the emergency switch via Romex. Needless to say this made...
  4. Yep, just a simple bypass type humidifier....

    Yep, just a simple bypass type humidifier.
    That's what I use, keeps the humidity level just fine in my house.
  5. Replies
    3
    Views
    405

    Untrue, higher indoor temp, lower capacity, lower...

    Untrue, higher indoor temp, lower capacity, lower btuh /kW ratio.
    Need proof? Pull up expanded ratings from the equipment you install.

    Now, creature comfort level is another issue. Cooler air...
  6. LOL! I love the pictorial description advising...

    LOL! I love the pictorial description advising you to connect the brass "things" directly to the gas regulator taps.
    Uhh, I think they're called brass "barb" fittings.
  7. Replies
    14
    Views
    793

    Check this manual install step #14....

    Check this manual install step #14.
    http://www.enerstat.com.au/sc-1manual.pdf
    Integral switches need to have minimum current of .08A in order to function. If the system does not draw this current...
  8. Replies
    14
    Views
    846

    What about ignitor voltage?

    What about ignitor voltage?
  9. Replies
    57
    Views
    1,849

    You're on the right track by logging usage, but...

    You're on the right track by logging usage, but like the others have said, logging the blower is useless. Why? Because it likely delays ~45sec each cycle on and ~120sec for each cycle off. How many...
  10. Replies
    31
    Views
    1,000

    Double check the 200, 210 & 340 setting. 340...

    Double check the 200, 210 & 340 setting.
    340 should not be shown if 210 is set properly, neither should 360 (the balance point cut out for aux heat)
  11. The most recent one is a Property Brothers...

    The most recent one is a Property Brothers episode, when Johnathan finds a sink wasn't draining, and then checks some other fixtures only to say, "hold on! We may have a major issue here!"
    Why...
  12. Is HGTV staged, or are their home inspectors complete MORONS!

    So, my wife and I are watching yet another catastrophic issue on an HGTV show that blows the new homeowners budget.

    The designers come up with these elaborate plans, only to discover one major...
  13. Replies
    11
    Views
    666

    Yes, good point, check the wire as well. Though,...

    Yes, good point, check the wire as well.
    Though, I've never repaired an ignition control using this method. Not saying it's not the problem, but never worked for me.
    You're right though, that's...
  14. Replies
    34
    Views
    1,893

    Obviously, to the consumer hard pipe is almost...

    Obviously, to the consumer hard pipe is almost always preferred. However, nobody wants to pay top dollar to have it installed. At twice the cost, it's hardly worth the value.

    To the contractor, we...
  15. Replies
    11
    Views
    666

    After main burner ignition, remove #5 terminal...

    After main burner ignition, remove #5 terminal wire from the 3-wire pilot off of the gas valve. If clicking stops, replace the 3-wire pilot, if not replace the ignition box.
    After ignition, the...
  16. Replies
    70
    Views
    2,478

    Here is a similar thread with HvacMedic & Jim...

    Here is a similar thread with HvacMedic & Jim Davis
    http://hvac-talk.com/vbb/showthread.php?955512-Combustion-Analysis&highlight=Air+speed+flue+temp

    I tend to agree with Medic that the issue may...
  17. Replies
    70
    Views
    2,478

    Yes, your wake theory is a more plausible...

    Yes, your wake theory is a more plausible explanation. It would be nice to see a thermal image of this.

    I guess the unfortunate consequence of creating greater turbulence, and improving surface...
  18. Replies
    70
    Views
    2,478

    The issue you are referring to is called "laminar...

    The issue you are referring to is called "laminar separation" the eddy currents are formed after the pocket or wake occurs. Do you understand the difference between laminar and turbulent?
    If the the...
  19. Replies
    70
    Views
    2,478

    I would tend to agree that counter flow HX design...

    I would tend to agree that counter flow HX design is more efficient, but why are counter flow units typically less efficient?
  20. Replies
    70
    Views
    2,478

    I have an old 80% 40mbtu furnace, I will try to...

    I have an old 80% 40mbtu furnace, I will try to find a 5 ton blower to test it.
    Damn, I need to build a test lab/ work shop!
  21. Replies
    70
    Views
    2,478

    Thanks, I'm afraid I've jacked up this thread. I...

    Thanks, I'm afraid I've jacked up this thread. I will start my own in pro section.
    .
  22. Replies
    70
    Views
    2,478

    Ok, well we can't post mfg performance data on...

    Ok, well we can't post mfg performance data on open forum, so maybe we could look at it in the private section.

    This is a great topic, and it is not my intention to discount anyone's expertise. I...
  23. Replies
    70
    Views
    2,478

    I'm not finding this analogy to have merit. 1....

    I'm not finding this analogy to have merit.
    1. The size of the hand, or volume of airflow would make a difference.
    2. The direction in which the heat is traveling makes a difference. A candle...
  24. Replies
    70
    Views
    2,478

    Thank you, Im interested to understand why this...

    Thank you, Im interested to understand why this is so.
  25. Replies
    70
    Views
    2,478

    So, if we can all get back to learning, how does...

    So, if we can all get back to learning, how does the forced air heat exchanger differ from, a coil or radiator?

    I do appreciate constructive debate.
  26. Replies
    70
    Views
    2,478

    Again, do we really need these personal attacks....

    Again, do we really need these personal attacks. If anyone on this site should refrain from such a sophomoric attitude, it would be an instructor, no?
  27. Replies
    70
    Views
    2,478

    What? I do believe it contributes. Your...

    What? I do believe it contributes. Your explanation in post #28 leads one to believe it opposes heat transfer.

    It's probably best for you to not take to personal attacks on others when they oppose...
  28. Replies
    70
    Views
    2,478

    "Turbulent water flow, like turbulent airflow,...

    "Turbulent water flow, like turbulent airflow, also reduces resistance to heat transfer."
    ..."turbulators, these devices create eddies as the water flows across them.
    Both methods of improving the...
  29. Replies
    70
    Views
    2,478

    Sorry, I was a motorcycle road racer for 10...

    Sorry, I was a motorcycle road racer for 10 years. I've removed thermostats from radiators, if ithey were causing a flow restriction. The only risk was overcooling, not allowing for you engine to...
  30. Replies
    70
    Views
    2,478

    Please show me one legitimate document that...

    Please show me one legitimate document that supports this claim.
    "Excessive flow will lower or stop heat transfer"
  31. Replies
    7
    Views
    715

    Solar vacuum tubes, for heating water

    Solar vacuum tubes, for heating water
  32. Replies
    70
    Views
    2,478

    +1

    +1
  33. Replies
    7
    Views
    578

    Sounds like something is miswired. Did it have...

    Sounds like something is miswired. Did it have multiple run capacitors? What is the model #?
  34. That's a bit of a hasty diagnostic don't you...

    That's a bit of a hasty diagnostic don't you think?
    No doubt, the inducer could very well be faulty, but there are a few more steps before charging someone 3-4 bills for a part.
  35. Like Rundawg stated, I think you need to T...

    Like Rundawg stated, I think you need to T connect into the draft press switch port to get a proper reading of the safety control operation.

    Keep in mind, the readings in the stack will be...
  36. Replies
    4
    Views
    539

    Not trying to offend you, but you may not want to...

    Not trying to offend you, but you may not want to mess with it if you're not sure how it works.

    If you applied for pro membership, we could provide manuals and detailed advice in the pro section...
  37. Replies
    9
    Views
    484

    This may help you get an idea about suggested...

    This may help you get an idea about suggested duct sizing.

    http://www.acca.org/wp-content/uploads/2014/01/Manual_D_verification.pdf

    Btw, your air volume at 820cfm for heating will give you a...
  38. Replies
    7
    Views
    418

    Without a load calculation it's hard to say. One...

    Without a load calculation it's hard to say.
    One way to check is the old unit. What was the size and efficiency?
    Did it heat well for you in past heating seasons?
    Did it short cycle, leaving you...
  39. Replies
    30
    Views
    1,743

    I did post #15, with the exception that you state...

    I did post #15, with the exception that you state the subcooling will rise, when in fact, a coil drenched in water will lower subcooling.
  40. Replies
    30
    Views
    1,743

    As the others have stated, the pressure drop will...

    As the others have stated, the pressure drop will make little difference, especially knowing that most gauges are not accurate to 1psi at normal operating pressures.

    What is important is the fact...
  41. Replies
    5
    Views
    555

    They give you a range, because there are...

    They give you a range, because there are different variables involved in designed air flow.
    You have to take all of the variables into account when adjusting blower speed, including temp rise.
    To...
  42. Thread: Puzzled

    by mgenius33
    Replies
    22
    Views
    1,484

    Ensure you have a compressor time off delay.

    Ensure you have a compressor time off delay.
  43. Replies
    13
    Views
    886

    All the more reason to learn every thing you can...

    All the more reason to learn every thing you can about them.
    In doing so, you might just make yourself more valuable and increase your income.
    Heat pumps are the most cost effective heat...
  44. Thread: TAM7 Reheat

    by mgenius33
    Replies
    3
    Views
    373

    I haven't thought too much into it, but if the...

    I haven't thought too much into it, but if the dip switch were set to HP, what would be any different from a defrost call from the heat pump? I don't recall if the defrost board sends out an O signal...
  45. Thread: TAM7 Reheat

    by mgenius33
    Replies
    3
    Views
    373

    Is dip switch S1-3 set for AC or HP?

    Is dip switch S1-3 set for AC or HP?
  46. Replies
    53
    Views
    2,351

    Why are you being so defensive? You are...

    Why are you being so defensive?

    You are receiving help for free.

    Yes, the beer can cold comment was a bit of silly ribbing, but all the others are legit.

    Icanhas was suggesting voltage...
  47. Replies
    53
    Views
    2,351

    We don't have much to go on here. You apparently...

    We don't have much to go on here.
    You apparently can't trouble shoot the issue.
    We cannot see what you're looking at.
    When you say furnace, is it an electric furnace, hydronic furnace, gas...
  48. Replies
    53
    Views
    2,351

    Sounds like there's some connection backwards, or...

    Sounds like there's some connection backwards, or the board is faulty causing more than one load in series.
    I would also double check the blower wiring and capacitor.
    Check the voltage to the...
  49. Replies
    17
    Views
    1,018

    My concerns would be ref flood back and duct...

    My concerns would be ref flood back and duct sweat.

    1st, Like the captcomp said, make sure you have a suction accumulator.

    2nd install a freeze stat on the coil that will energize low speed...
  50. Replies
    36
    Views
    1,618

    It's funny that everyone compares the hoses at 6'...

    It's funny that everyone compares the hoses at 6' lengths.
    Let's keep in mind, friction rate has to do with length as well as diameter.

    I do believe that a larger hose will evacuate more...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event