  1. Replies
    36
    Views
    720

    Pretty much. As said before, don't try this at...

    Pretty much.

    As said before, don't try this at home.
    Or do, whatever.

    I hate part (only) warranty anyways. Homeowner installs get no warranty. Better profit that way.
  2. Replies
    36
    Views
    720

    1. I doubt you need 1 1/8th. 2. I doubt you need...

    1. I doubt you need 1 1/8th.
    2. I doubt you need a system, that would need 1 1/8th.
    3. I doubt you should be installing this system.

    When you bought it off the internet, did they explain it has...
  3. Replies
    14
    Views
    291

    I'm just dreaming of air conditioning season.

    I'm just dreaming of air conditioning season.
  4. Replies
    14
    Views
    291

    Go with the heat pump. Even if the place isn't...

    Go with the heat pump.
    Even if the place isn't setup for "perfect" heating, your still going to be dumping heat into the space at a 1/3 of the cost of your baseboards.

    BTW, you see those holes...
  5. I think the question, is why is range of...

    I think the question, is why is range of acceptable temp rise a 30* range.

    How come the range isn't 45-65 (20* range)
  6. Put that time delay on. It's important enough,...

    Put that time delay on.
    It's important enough, that goodman made an entire kit dedicated to upgrading older models that didn't come equipped with the delay.

    For reasons as loonie said.
  7. Baldy, come on! Amana uses an all stainless,...

    Baldy, come on!

    Amana uses an all stainless, primary and secondary, tubular HX.

    Older models did have issues with the primary/secondary joint, because the joint where the primary tubes entered...
  8. DIY DIY DIY. This is turning into a joke. You...

    DIY DIY DIY.

    This is turning into a joke.
    You probably don't need a new coil.
    Hacking up a unit and "bolting it up" to a furnace is a joke.

    There a simple process for installing an uncased...
  9. The preheater only comes on during low temps....

    The preheater only comes on during low temps.
    The preheater keeps the compressor warm during the off cycle, creating easier starts.
    Doesn't matter what the increased cost is, it needs to be turned...
  10. Good lord. I recommend this thread be locked...

    Good lord.

    I recommend this thread be locked to DIY.
  11. It absolutely will increase your energy bill. ...

    It absolutely will increase your energy bill.

    It will make it last longer, and should be turned on in any area that gets cold.
  12. You need a contractor. All gas furnaces have...

    You need a contractor. All gas furnaces have flues.
    Dimensions of the coil mean nothing for a contractor. Easy fix.
    You may be able to reuse the coil, depending on the application.
  13. I'm very confused at what your trying to do. You...

    I'm very confused at what your trying to do.
    You need a new furnace. You can use the existing coil. Need a new stat. Done and done.

    Your air handler can't be "converted".
  14. Ran for two days, and then failed again? Time...

    Ran for two days, and then failed again?

    Time to find a different tech. There's something basic he's missing, and jumped to the board.
  15. Replies
    13
    Views
    354

    Sounds like your all setup. Sounds like you...

    Sounds like your all setup.

    Sounds like you have more of a duct issue.
  16. Replies
    13
    Views
    354

    Looks big enough to me for you to have a heat kit...

    Looks big enough to me for you to have a heat kit in it. You probably do.
  17. Replies
    13
    Views
    354

    More than likely, the installer didn't mark the...

    More than likely, the installer didn't mark the panel with which heat kit he installed.

    Take a picture of the high voltage wiring going into the furnace. Don't take any doors off.
  18. I don't see where anyone gave you anything other...

    I don't see where anyone gave you anything other than professional advice.

    Plus, you came back a month later, just to post this?
    As you said:
    "Wow. Really? Get a life."
  19. lol. Last furnace you'll have to buy. Untill you...

    lol. Last furnace you'll have to buy. Untill you get tired of this POS failing on you all the time.
  20. Whats the fossil fuel you'll be using? You may...

    Whats the fossil fuel you'll be using?

    You may be able to reuse the coil in the unit. You'd need to purchase a new furnace.
  21. Replies
    9
    Views
    357

    Take a picture of the entire boiler room.

    Take a picture of the entire boiler room.
  22. Replies
    11
    Views
    399

    If thats your diagnostic for the board losing...

    If thats your diagnostic for the board losing power, and are a tech, you've got alot to learn.
    If your in the industry, apply for pro status, so we can teach you behind closed doors.

    If your not...
  23. Replies
    11
    Views
    399

    have you inspected the heat exchanger recently?

    have you inspected the heat exchanger recently?
  24. Do not use the fireplace if you value your life....

    Do not use the fireplace if you value your life.

    The situation you describe with your landlord is specifically why I don't like dealing with rental property.
    Normally nothing against the tenant....
  25. Replies
    47
    Views
    1,467

    Goodmana. Their adjustable too.

    Goodmana.
    Their adjustable too.
  26. Anyone else read "landlord"? Don't use that...

    Anyone else read "landlord"?

    Don't use that fireplace.
  27. That, is brilliant.

    That, is brilliant.
  28. Replies
    643
    Views
    120,978

    I didn't go, other tech in the company did. ...

    I didn't go, other tech in the company did.

    Goes out, no heat. later 80's bryant, 3 wire pilot. Tech finds rollout tripped. Resets rollout, doesn't roll. Checks carrier HX, corrosion all over the...
  29. Replies
    48
    Views
    1,092

    Which is why I recommend against straight up...

    Which is why I recommend against straight up electric.

    I would highly recommend staying away from a electric boiler. They are extremely high maintience, high cost of repairs, high installation...
  30. Replies
    8
    Views
    265

    With a system that complicated, I would want the...

    With a system that complicated, I would want the manufacturers thermostat.
  31. Replies
    48
    Views
    1,092

    Yeah.... Just about anything is going to be more...

    Yeah....
    Just about anything is going to be more efficient than straight up electric heating.
    Solar? Open fire in the house?
    Burning trash?

    Straight up electric heat is extremely inefficient....
  32. You're getting to involved with your furnace....

    You're getting to involved with your furnace.
    Seriously. Step back. Let it do it's thing.
  33. As a side note, unrelated to the zoning/boards: ...

    As a side note, unrelated to the zoning/boards:

    You need to have that heat exchanger inspected, specifically where the primary heat exchanger meets the secondary in the back.

    It's pretty...
  34. Well, looks like you have some issues with the...

    Well, looks like you have some issues with the installation.

    That black pipe must extend past the metal flue pipe, past the cap.
    If not, the condensate that comes from that pipe will hit the cap,...
  35. I've had a few that blew up, nothing physical....

    I've had a few that blew up, nothing physical.
    Normally, I just firmly, at their voice level:
    "Sir, you will not curse at me. If you do, I'll be leaving."w
    Normally they calm down, and we discuss...
  36. Ok, just to be clear. I thought from your first...

    Ok, just to be clear. I thought from your first post this would be a "floor furnace". I misunderstood you. This sounds more like a standard high efficiency furnace, in your crawl space (hence under...
  37. Welcome back benny :-P I'd bet the equipment...

    Welcome back benny :-P

    I'd bet the equipment isn't the issue. I doubt it's the duct either.
    I'd be looking for at install wiring/charging/airflow.
  38. Replies
    224
    Views
    9,694

    You guys are missing the point.

    You guys are missing the point.
  39. Replies
    224
    Views
    9,694

    Distance to panel, location of wiring all come...

    Distance to panel, location of wiring all come into play. Granted, you could just go bigger than required.

    Forget sizing, what TYPE of wire needs to be used?
  40. Replies
    224
    Views
    9,694

    Exactly. There are too many possible situations...

    Exactly.
    There are too many possible situations that will lead him to bad judgement, on the technical side, and on the business side.

    Just to bring up a single question, that is asked multiple...
  41. Thread: no fan on?

    by hvacvegas
    Replies
    3
    Views
    230

    Looks like the fan option is behind the swinging...

    Looks like the fan option is behind the swinging door, according to the doc dogboy posted.
  42. That furnace is absolutely oversized, and is most...

    That furnace is absolutely oversized, and is most likely the issue your having.

    As far as rebuilding parts, there is not 1 part on a residential furnace i would try and rebuild.

    We'll see you...
  43. Glad to hear!

    Glad to hear!
  44. I doubt it. Got any pictures?

    I doubt it.

    Got any pictures?
  45. Replies
    5
    Views
    303

    Your most likely talking about the silicone...

    Your most likely talking about the silicone nitride, stick ignitor. Has a large porclean (sp) with just a little 1/2" of rod showing.

    FYI, if it's an A(G)MV, it's most likely not a 120v ignitor...
  46. 95% of what we do is retro work. We practically...

    95% of what we do is retro work. We practically only sell amana equipment. I've seen ALOT of DSZC16's go in, and done a lot myself.

    What are you using for "ramping profile"?

    Have you seen the...
  47. Believe it or not, you answered the question :)....

    Believe it or not, you answered the question :).
    Just wanted it make sure you were using AHRI match. Lots of guys don't, and then I find 5tons on 4 ton coils.

    We've actually never had this...
  48. So to be clear, your using a MBVC1600 on 5 ton...

    So to be clear, your using a MBVC1600 on 5 ton systems?

    What coils are you using?
    How long ago?
  49. What tonnage is the outdoor unit?

    What tonnage is the outdoor unit?
  50. Replies
    37
    Views
    1,279

    1. If anyone here can produce documentation from...

    1. If anyone here can produce documentation from the EPA restricting me from adding refrigerant to a leaking residential unit. Do so. Otherwise, there is NO LEGAL RESTRICTION. Restriction is only...