  1. Replies
    5
    Views
    2,329

    Guess I should have mentioned that it is on...

    Guess I should have mentioned that it is on Natural Gas.

    If the wall switch is in the off position nothing will work. With the switch in the on position the remote will work.

    I see what looks...
  2. Replies
    5
    Views
    2,329

    (Heat N Glo) No High Flame

    We have a Twilight II Heat n Glo fireplace using the Intellifire control which uses the RCT-MLT-II remote control unit. Also there is a wall switch for the fireplace as well and no blower. So my...
  3. Replies
    14
    Views
    1,892

    The units sit next to each other.... some pics.....

    The units sit next to each other.... some pics..

    http://i72.photobucket.com/albums/i170/mpnx2/008-1.jpg

    Return Air
    http://i72.photobucket.com/albums/i170/mpnx2/009-1.jpg

    Return Air For...
  4. Replies
    14
    Views
    1,892

    The furnace portion is in the attic and then the...

    The furnace portion is in the attic and then the condensers are outside...

    So two furnaces in the attic and two condensers outside...
  5. Replies
    14
    Views
    1,892

    Looks like the closest listing on Bpi.org for me...

    Looks like the closest listing on Bpi.org for me is 97 miles away...

    Maybe I will give them a call Monday
  6. Replies
    14
    Views
    1,892

    Thats seems to be what I got. I dont even know...

    Thats seems to be what I got. I dont even know how much tonnage I need. 10 tons seems excessive. Our home is a bit over 3200 sq ft. But I do have some rooms with 14' ceilings so I know this adds alot...
  7. Replies
    14
    Views
    1,892

    Seems that it is lower during the heating...

    Seems that it is lower during the heating seasons. Seems I am always getting shocked from the static. Acullay I have noticed it quite a bit lately. Will have the unit in the "System Off" more lower...
  8. Replies
    14
    Views
    1,892

    Carrier Humidity Control?

    Our home built in late '07 has the Carrier Infinity unit installed. We have 2 5ton units. I am interested in learning more about the humidity control option available for our system. I understand...
  9. Replies
    79
    Views
    6,018

    I assume that should be up in the attic under the...

    I assume that should be up in the attic under the air handler? I know there is a drain pipe that runs out onto my patio...

    Well.....for an update Carrier is coming out to look at the units next...
  10. Replies
    79
    Views
    6,018

    I dont mind paying a higher price if the work is...

    I dont mind paying a higher price if the work is preformed well.

    I forwarded this thread to my GC.....

    I will keep everyone posted on the outcome...

    Dash....do you want to come to CA high...
  11. Replies
    79
    Views
    6,018

    Thats the whole home.....with those numbers what...

    Thats the whole home.....with those numbers what kind of tonnage should I be using?

    One unit just gave me a "System Malfunction" on the control. I looked at the faults and it says "Possible Frozen...
  12. Replies
    79
    Views
    6,018

    Some added info.... Along with my blueprints I...

    Some added info....

    Along with my blueprints I found my Certification on Compliance...

    It has the HAVC info on it from the acrhitect.

    Total Heating Load (Btu/hr)
    Furnace 71967

    Sensible...
  13. r

    r
  14. Replies
    79
    Views
    6,018

    The control is now displaying the filter...

    The control is now displaying the filter notification....
  15. Replies
    79
    Views
    6,018

    I will call Carrier but accroding to the webstie...

    I will call Carrier but accroding to the webstie they are now closed... So I will call Tuesday.

    As long as its fixed properly thats fine.

    I changed the Filter uder the Accessories menu to...
  16. Replies
    79
    Views
    6,018

    Under the install menu I changed it from EAC to...

    Under the install menu I changed it from EAC to Media+EAC we will see what happens...

    So there is nothing published about the SP in these units?

    Thanks for everyones help...I cant be the only...
  17. Replies
    79
    Views
    6,018

    I dont know what the coil is in that...

    I dont know what the coil is in that pictures....great this keeps getting worse..

    What is PD pressure Drop:confused:
  18. Replies
    79
    Views
    6,018

    He said he had it setup for EAC on a timed...

    He said he had it setup for EAC on a timed basis...
  19. Replies
    79
    Views
    6,018

    Some is flex the other is covered with insulation...

    Some is flex the other is covered with insulation and its stiff so I assume its sheet metal...some pictures

    http://i72.photobucket.com/albums/i170/mpnx2/Picture768-1.jpg
    ...
  20. Replies
    79
    Views
    6,018

    I ask him and he said no for both.... These...

    I ask him and he said no for both....

    These units are capable of 1750 each correct?

    I am not going to let it drop if he thinks so he is mistaken..neither will my GC. I do know the ducting is...
  21. Replies
    79
    Views
    6,018

    What is filter measuring PD? He said code 161...

    What is filter measuring PD?

    He said code 161 was from high SP which it clearly states....

    codes 31, and 32 high and low pressure switch open he never really explained....
    Zone2 sirflow...
  22. Replies
    79
    Views
    6,018

    Unit one with 3 zones all open the unit says the...

    Unit one with 3 zones all open the unit says the zones are at 15 or open

    SP is 1.14 High Stage


    Second unit with all four zones open

    Sp is 1.01 High Stage
  23. Replies
    79
    Views
    6,018

    Well my GC and the HVAC company just left. The...

    Well my GC and the HVAC company just left. The installer was able to lower the SP a bit on each unit by first looking in the Air Handlers in the attic and found some of the isulation was blocking the...
  24. Replies
    79
    Views
    6,018

    I have an appt setup with my GC and the...

    I have an appt setup with my GC and the installers in Friday...I will show them everything that I have found and go from there.....

    From what I have read it seems Carrier stands behind there...
  25. Replies
    79
    Views
    6,018

    I am working on that as we speak....my GC will be...

    I am working on that as we speak....my GC will be by today for some other things and I will let him know then....I will keep everyone posted..
  26. Replies
    79
    Views
    6,018

    Yes the filters are in the return air grills.......

    Yes the filters are in the return air grills.... there are 2 per unit one has 2 30X20X1 and the other has a 30X20X1 and a 20X14X1....so there are more on the units in the attic? Would this increse my...
  27. Replies
    79
    Views
    6,018

    Thanks for the correction..... As a test today...

    Thanks for the correction.....

    As a test today I took the return air filters out and did another SP test....one unit came back with .99 and the other .94 according to the previous post these...
  28. Replies
    79
    Views
    6,018

    Here is a link to the specs of the SEER 21...

    Here is a link to the specs of the SEER 21 units...

    http://www.residential.carrier.com/products/acheatpumps/ac/infinity.shtml

    I will try to get it done through my GC first before I do anything...
  29. Replies
    79
    Views
    6,018

    I will let my GC know on Monday who I have a good...

    I will let my GC know on Monday who I have a good relationship with. I am hoping that he will than make the appropriate calls and get this resolved....
  30. Replies
    79
    Views
    6,018

    Its 2 20X30 returns per system. Orignally I had 1...

    Its 2 20X30 returns per system. Orignally I had 1 on each but the came and added another for the pressures.....

    Where can I find someone that can do the heat loading tests?
  31. Replies
    79
    Views
    6,018

    I do get the change filiters notification and...

    I do get the change filiters notification and when I do get I have changed them. Its like every three months or so....

    Man I am pretty upset about all of this. I guess on Monday I will be making a...
  32. Replies
    79
    Views
    6,018

    The other unit has similar numbers and faults ...

    The other unit has similar numbers and faults

    With the execption of
    34-Ignition Fault 2 faults
    42 Inducer Fault 1 event
    excess pressure
    limited airflow shutdown

    Cycles are
  33. Replies
    79
    Views
    6,018

    There seesm to be a lot of A/C cycles listed too:...

    There seesm to be a lot of A/C cycles listed too:
    Power 15
    Low cool 5941
    High cool 443
  34. Replies
    79
    Views
    6,018

    The faults listed are 161 excess static...

    The faults listed are

    161 excess static pressure stagedown 15 events
    31-high pressure switch open 1 event
    32 low pressure switch open 10 events
    zone 2 airflow limited shutdown occured 2 events...
  35. Replies
    79
    Views
    6,018

    Thanks for the quick help....here is a run down...

    Thanks for the quick help....here is a run down of on units results from the checkout


    Duct assessment
    Zone Cap
    Master Bed 34%
    Living 16%
    Nook 39%
    Damper Leakage 11%
  36. Replies
    79
    Views
    6,018

    Oh I should have mentioned that our ducts run...

    Oh I should have mentioned that our ducts run through the attic. We also have the Radient barroer install on the roof and our exterior walls are insulated with R-21 and I beleive its R-38 in the...
  37. Replies
    79
    Views
    6,018

    Carrier Infinity Concerns

    Hello I am new here and I was hoping that I could find some insight here on how to make my HVAC unit perform better.

    We had a home built a little over a year ago and chose to have a Carrier...
Results 1 to 37 of 37