    It would trend too drop back into start as the...

    It would trend too drop back into start as the run contact amps are not high enough to hold it in run.
  2. Replies
    4
    Views
    388

    The rc series of relays are known compressor...

    The rc series of relays are known compressor killers. Get the right relay and check the run cap if so equipped. If it still wont start its a bad compressor.
  3. Replies
    34
    Views
    1,341

    If your readings are correct and you tapped it...

    If your readings are correct and you tapped it properly it would be a inefficient compressor.
  4. Replies
    8
    Views
    638

    Sounds to me like you have a restriction-Thats...

    Sounds to me like you have a restriction-Thats why the compressor would not start-It had not unloaded-The ice on the liquid line at the cap tube is a clue. Normally there is a dryer just ahead of...
  5. Replies
    52
    Views
    8,527

    I used it one time. Installed per manufactures...

    I used it one time. Installed per manufactures instructions. In 3 days the compressor was locked up-never again. :gah:
  6. Replies
    2
    Views
    1,060

    In domestic there is a oven sensor that cycles...

    In domestic there is a oven sensor that cycles the tempature. If there is one it would be suspect. Get the owners manual or service manual, it will tell you the failure per defect code. If those are...
  7. Replies
    5
    Views
    905

    I give her kuddos for having the grit to be a...

    I give her kuddos for having the grit to be a female tech. No problem there. Its just that the encounters they showed is nothing like it is in the real world.

    For instance after replacing a oven...
  8. Thread: Freon

    by frigeman
    Replies
    29
    Views
    4,513

    The original Hot Shot had propane in it and was...

    The original Hot Shot had propane in it and was not to be used in automotive air conditioning.
    They have since removed it from the formula.
  9. Replies
    5
    Views
    905

    The appliance Tech called the oven sensor a...

    The appliance Tech called the oven sensor a thermostat. The sensor was prehung for her. Checked the old sensor after replacing it. I was not impressed. The whole segment seemed too be a lot of fluff...
  10. Replies
    27
    Views
    1,749

    Short simple advice from a old timer. The...

    Short simple advice from a old timer.


    The only washer I would buy for my own use is a whirlpool top loading washer.

    :grin2:
  11. Replies
    22
    Views
    3,884

    X2

    X2
  12. Replies
    13
    Views
    1,089

    Electronics and household refrigerators have not...

    Electronics and household refrigerators have not been a good marriage. The high cost of electronic componrents just to see if you need another has ruined a once profitable business. Consumers are...
  13. Replies
    22
    Views
    1,426

    I had a customer ask how much my service call was...

    I had a customer ask how much my service call was so I told her. She then said if you can get here today and gaurantee me that you can fix it for the cost of the call come on out. Told her I did not...
  14. Replies
    5
    Views
    667

    Nothing goes in a refrigeration system except...

    Nothing goes in a refrigeration system except refrigerant and oil. There are many horror storys here about the use of leak stop products. Find the leak and fix it period.




    :CU:
  15. Replies
    42
    Views
    3,719

    Run

    Run
  16. I do beleive that is the worst I have seen...

    I do beleive that is the worst I have seen here-go figure
  17. Replies
    47
    Views
    7,149

    Try This

    Try This
  18. Replies
    20
    Views
    2,253

    Thats ugly-I wouldnt do that even with your...

    Thats ugly-I wouldnt do that even with your tools.


    Good finished product
  19. Replies
    31
    Views
    6,262

    What were they thinking? :oops:

    What were they thinking?





    :oops:
  20. Replies
    4
    Views
    1,691

    Thats a older model. The defriost timer is behind...

    Thats a older model. The defriost timer is behind the light sheild on the RH side of the food section top back.

    It is a mechanical 4 wire timer and not electronic-It defrosts for 21 minutes every...
  21. Replies
    4
    Views
    1,691

    Thats not a complete model number. If its under...

    Thats not a complete model number. If its under 10 years old its under the control panel where the lights are in the food section top. Its electronic and is in the RR area in a white plastic box.

    ...
  22. Replies
    14
    Views
    1,355

    Did you get this fingured? Post up the progress...

    Did you get this fingured? Post up the progress and we will play with it some more.
  23. Replies
    14
    Views
    1,355

    This model has a mechanical damper that controls...

    This model has a mechanical damper that controls the air flow from the freezer. Based on the info you have given me then there has to be ice in that duct blocking the air flow from a stopped up...
  24. Replies
    14
    Views
    1,355

    Moisture in the mullion and top panel area...

    Moisture in the mullion and top panel area indicates a ice build up in the freezer-Either failing to defrost or defrost water not draining. Either way it is a freezer problem.

    Most modern...
  25. Replies
    14
    Views
    1,355

    The primary reason for a poor food section...

    The primary reason for a poor food section tempature is the freezer evaporator is blocked or partially blocked with a ice build up from a defrost failure.

    Take the freezer section tempature if it...