    I check caps under a load sometimes the formula...

    I check caps under a load sometimes the formula is amp draw times 2650 /voltage at cap. Take the amp draw right at the cap and the voltage at the cap leads.
  2. Replies
    15
    Views
    1,343

    I worked out of a ford transit once. That was...

    I worked out of a ford transit once. That was just about too small. Back in a ford 250 now I can breathe and there is room for a trash can.
  3. Replies
    23
    Views
    1,667

    The company that I work for has a waiver form...

    The company that I work for has a waiver form explaining that a dangerous condition MAY exist. We have the homeowner sign it and leave a copy.
  4. Replies
    16
    Views
    1,058

    Thanks, and thanks

    Thanks, and thanks
  5. Replies
    30
    Views
    2,817

    Check compressor discharge temp. Should be less...

    Check compressor discharge temp. Should be less than 200. Chk compressor amp draw and try to pump system down. Low superheat= flooded evap. You've removed refrigerant. Is the compressor pumping...
  6. Replies
    16
    Views
    1,058

    hot water heater hot on top

    Rheem 50 gal 40k bth hot water heater getting hot on top. Homeowner had other company out told her flue was plugged. I went on roof checked flue cap and inspected flue. I disconnected flue in attic...
  7. Thanks, I just started wondering what the benefit...

    Thanks, I just started wondering what the benefit is in wiring to the cap and then using one more piece of wire and three connectors as some manuf. do.
  8. why do some manf. wire condenser fan run winding to cap c, others only t2

    Why do some manufacturers wire condenser fan run winding lead to capacitor "c" terminal and others wire connect only to t2 just wondering
  9. Replies
    58
    Views
    7,145

    Except for units that use a txv in the od unit....

    Except for units that use a txv in the od unit. After the first few years of servicing only bryant equip. the company I was working for started also dealing lennox. I noticed the abscence of...
  10. Replies
    9
    Views
    1,546

    liquid line strainer just before metering device...

    liquid line strainer just before metering device could be blocked, should be freezing or have a temp diff. at restriction
  11. Replies
    27
    Views
    1,953

    sounds like a lot of guessing until someone comes...

    sounds like a lot of guessing until someone comes out. can't believe they wont be back until next week
  12. yep, better just bite the bullet and let the tech...

    yep, better just bite the bullet and let the tech try one thing at a time.
  13. Keep looking for a contractor. would never use...

    Keep looking for a contractor. would never use flex unless sleved with rigid pipe. What are they going to with heat tape on the condensate line and then let the trap freeze? I know that they make a...
  14. Replies
    4
    Views
    514

    I vote 3tons or is it 36,000 btu?

    I vote 3tons or is it 36,000 btu?
  15. Would be better to get these systems in during...

    Would be better to get these systems in during construction in my opinion for the simple fact that it can be scheduled and completed during the normal constuction cycle. You know before flooring is...
  16. Would change evap and mtering device. R410A...

    Would change evap and mtering device. R410A metering devices are about 15% smaller than on r22. Also How much Oil will be left in the r22evap? The question is how much wax will be in that oil to clog...
  17. Replies
    12
    Views
    1,977

    Agree with beenthere. also would have electrician...

    Agree with beenthere. also would have electrician check furnace, o.d. unit wiring.
  18. Replies
    8
    Views
    941

    sounds like liquid may be migrating through...

    sounds like liquid may be migrating through system, is condenser coil clean, ran into this once and the s/a's were all closed
  19. Replies
    4
    Views
    1,115

    should not have to add oil

    should not have to add oil
  20. Replies
    25
    Views
    1,686

    Agree with Crazy4. As for the txv I would try to...

    Agree with Crazy4. As for the txv I would try to manipulate it with hot water soaked rag or glass off ice water.
  21. Yes can be done, in fact I use that application...

    Yes can be done, in fact I use that application in my house. Just remember that the HP operation will supply lower temps than your fossil fuel system. The contractor that you decide to use should be...
  22. Replies
    13
    Views
    887

    Something to think about. The new ahu will be...

    Something to think about. The new ahu will be matched to the od unit, and have a new blower motor instead of a 26 year old one (if not already replaced).
  23. Generally the reversing valve energizes when the...

    Generally the reversing valve energizes when the tstat is placed in "cool" and de-energizes when switched off of cool. This can be the opposite way in some systems but it is interesting that until...
  24. Wait for the Tech

    As stated in the prev. posts there is really no actions that you can take except for waiting for the tech to arrive. I can explain a little about what is happening though.
    The fast blinking light is...
  25. Replies
    33
    Views
    2,073

    electronic leak detector

    I have found that in addition to pressure checking the system the use of an electronic leak detector saves me and the customer time and money. Yes I had to buy it myself. No I don't cry about it to...
Results 1 to 25 of 30
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event