Search:
Type: Posts; User: igwt777
Search: Search took 0.01 seconds.
-
10-14-2005, 05:58 PM
Thread: ANYBODY SEEN MY RACCOON???
by igwt777- Replies
- 21
- Views
- 4,404
Pictures....... who needs pictures??? :D
Pictures....... who needs pictures??? :D
-
10-05-2005, 04:20 PM
Thread: Garage install
by igwt777- Replies
- 19
- Views
- 2,679
Nice job!! Wondering if you fabricate TDC joints...
Nice job!! Wondering if you fabricate TDC joints also?
-
09-30-2005, 10:33 PM
Thread: York compressor lockout
by igwt777- Replies
- 13
- Views
- 3,289
You can install a pressure / temp logger. This...
You can install a pressure / temp logger. This logger will monitor pressure and temp so when you come back you know what really happened and when. SUPCO makes low price loggers perfect for this...
-
09-30-2005, 09:22 PM
Thread: superheat/subcooling
by igwt777- Replies
- 11
- Views
- 1,377
Every A/C system must have a charging procedure...
Every A/C system must have a charging procedure and chart provided by the manufacturer. Always follow manufacturers data.
-
09-30-2005, 07:17 PM
Thread: cleaning a evaporator coil
by igwt777- Replies
- 4
- Views
- 1,027
The only way to get it real clean is to remove...
The only way to get it real clean is to remove the coil, apply chemical cleaner an then rinse with lots of water.
If you do it right you don't have to do it twice. :D -
09-30-2005, 09:45 AM
Thread: Compressor icing
by igwt777- Replies
- 33
- Views
- 2,331
cybarr 1st post says:...
cybarr 1st post says:
----------------------------------------------------
I went on a call, 5 ton split system.
Pressures 53/165 line temp 30/83
return air 78 deg supply 56 deg ... -
09-28-2005, 04:05 PM
Thread: Putting a scent into refrigerants
by igwt777- Replies
- 14
- Views
- 1,138
So now the customer will know how much...
So now the customer will know how much refrigerant is leaking .01 oz/year.
Maybe customers can choose the scent they like.
I suggest dollar bill scent, then you will know how much you have to... -
09-28-2005, 03:38 PM
Thread: which charging technique?
by igwt777- Replies
- 12
- Views
- 983
Cap tube systems shall be charged using the...
Cap tube systems shall be charged using the Superheat method
Piston systems shall be charged using the Superheat method
Expansion valve systems shall be charged using the Subcooling method -
09-27-2005, 11:21 PM
Thread: Staple guns rock
by igwt777- Replies
- 23
- Views
- 3,574
Don't mess with that photo :D
Don't mess with that photo :D
-
09-27-2005, 05:01 PM
Thread: Staple guns rock
by igwt777- Replies
- 23
- Views
- 3,574
You are not alone!!
Check this out
[Edited by igwt777 on 09-27-2005 at 05:07 PM] -
09-26-2005, 11:41 PM
Thread: re-do it not enough support
by igwt777- Replies
- 10
- Views
- 2,091
Nope!! That's overcurrent protection !!!
Nope!! That's overcurrent protection !!!
-
09-26-2005, 10:17 PM
Thread: Phase protectors
by igwt777- Replies
- 6
- Views
- 695
I always recommend 3 phase monitors (new installs...
I always recommend 3 phase monitors (new installs or when replacing a compressor) It's a cheap insurance for the customer. Low cost vs. high protection.
-
09-26-2005, 07:15 PM
Thread: vacuum pressures
by igwt777- Replies
- 19
- Views
- 1,229
http://www.imagewiz.net/usr/hvac1/20884_132706.gif...
http://www.imagewiz.net/usr/hvac1/20884_132706.gif
What is a micron?
A micron is a metric measure and is defined as 1 millionth of a meter or 1 thousandth of a millimeter.
Most people in the... -
09-26-2005, 08:52 AM
Thread: vacuum pressures
by igwt777- Replies
- 19
- Views
- 1,229
How often do you get to 350 and hold for one...
How often do you get to 350 and hold for one minute? What kind of vacuum setup you use?
-
09-25-2005, 11:22 PM
Thread: Yellow Jacket SuperEvac MANIFOLD
by igwt777- Replies
- 6
- Views
- 627
Do you use stainless steel flex hoses or the...
Do you use stainless steel flex hoses or the heavy duty black ones?
igwt777 -
09-25-2005, 08:15 PM
Thread: vacuum pressures
by igwt777- Replies
- 19
- Views
- 1,229
if you are pulling to 500 you are on the safe...
if you are pulling to 500 you are on the safe side.
-
09-25-2005, 08:11 PM
Thread: vacuum pressures
by igwt777- Replies
- 19
- Views
- 1,229
Welcome to HVAC-Talk You will understand that...
Welcome to HVAC-Talk
You will understand that type of answers on the run!!! :D -
09-25-2005, 08:07 PM
Thread: vacuum pressures
by igwt777- Replies
- 19
- Views
- 1,229
Always pull down to 500 microns and replace...
Always pull down to 500 microns and replace filter driers. This will save you lots of time. Do it well the first time... then you don't have to come back and do it again.;)
-
09-24-2005, 09:57 PM
Thread: Se Habla Expañol
by igwt777- Replies
- 54
- Views
- 2,072
Definitivamente hacia falta un traductor...
Definitivamente hacia falta un traductor certificado por HVAC-Talk.
LOL!!! -
09-24-2005, 09:47 AM
Thread: Geeeezzz!!!
by igwt777- Replies
- 38
- Views
- 5,669
LOL !!
LOL !!
-
09-21-2005, 08:56 PM
Thread: Selling 3 Phase Rooftop Units
by igwt777- Replies
- 14
- Views
- 1,646
IMO I keep the 3 phase units.
IMO I keep the 3 phase units.
-
09-20-2005, 10:55 PM
Thread: Making 90's without using fittings
by igwt777- Replies
- 3
- Views
- 1,921
Try this anyou will see ...
Try this anyou will see
http://hvac-talk.com/vbb/showthread.php?threadid=84876 -
09-20-2005, 09:37 PM
Thread: Comfortstar mini split question
by igwt777- Replies
- 8
- Views
- 891
Never seen a minisplit whith heating device.
Never seen a minisplit whith heating device.
-
09-20-2005, 09:19 PM
Thread: Taking corners without fittings!
by igwt777- Replies
- 12
- Views
- 2,811
-
09-20-2005, 09:06 PM
Thread: Taking corners without fittings!
by igwt777- Replies
- 12
- Views
- 2,811
Now looks better!!
Now looks better!!
Results 1 to 25 of 172